Skip to content

American Canyon · Zoning · LI

American Canyon LI zoning: height, setbacks and lot size

In American Canyon's LI zone, buildings can be up to 40 feet (3.0 stories) tall, the front setback is 20 feet and the minimum lot size is 20,000 sq. ft. (American Canyon code, read October 2026).

Key points

  • Maximum building height: 40 feet
  • Maximum number of stories: 3.0 stories
  • Minimum front setback: 20 feet
  • Minimum side setback: 5 feet (one-story)
  • Minimum rear setback: 10 feet
  • Minimum lot size: 20,000 sq. ft.
  • Maximum floor area ratio (FAR): 50% (labor-intensive uses)

LI is a zoning district in American Canyon. Every value below was read from the American Canyon Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in LI

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
40 feet
§ 19.14.060 · code text
Table row “Maximum building height”, column “LI”: 40 feet
Maximum number of stories
3.0 stories
§ 19.14.060 · code text
Table row “Maximum number of stories”, column “LI”: 3.0
Minimum front setback
20 feet
§ 19.14.060 · code text
Table row “Minimum front yard”, column “LI”: 20 feet
Minimum side setback
5 feet
Applies: one-story
§ 19.14.060 · code text
Table row “One-story”, column “LI”: 5 feet
Minimum rear setback
10 feet
§ 19.14.060 · code text
Table row “Minimum rear yard”, column “LI”: 10 feet
Minimum lot size
20,000 sq. ft.
§ 19.14.060 · code text
Table row “Minimum area per lot”, column “LI”: 20,000 sq. ft.
Maximum floor area ratio (FAR)
50%
Applies: labor-intensive uses
§ 19.14.060 · code text
Table row “Labor-intensive uses”, column “LI”: 50%

Uses in LI

Uses the code's use tables allow in LI, or allow with a permit. Each links to its page with the code section.

When a different number applies

The code sets other values for particular lots, buildings or locations in LI:

  • Minimum side setback: 10 feet — two-story § 19.14.060
  • Maximum floor area ratio (FAR): 70% — low-labor uses § 19.14.060

Not on this page

We did not find a general lot coverage, density limit for LI in the zoning tables we read. The code may still set one elsewhere — check the American Canyon Municipal Code.

Other American Canyon zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in American Canyon's LI zone?

40 feet — American Canyon Municipal Code § 19.14.060.

What is the maximum number of stories in American Canyon's LI zone?

3.0 stories — American Canyon Municipal Code § 19.14.060.

What is the minimum front setback in American Canyon's LI zone?

20 feet — American Canyon Municipal Code § 19.14.060.

What is the minimum side setback in American Canyon's LI zone?

5 feet (one-story) — American Canyon Municipal Code § 19.14.060.

What is the minimum rear setback in American Canyon's LI zone?

10 feet — American Canyon Municipal Code § 19.14.060.

General information, not legal advice.

Ask about an American Canyon property in LI

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on American Canyon