Arcadia · Zoning · R-0
Arcadia R-0 zoning: height, setbacks and lot size
In Arcadia's R-0 zone, generally buildings can be up to 25 ft for lots less than 75 ft wide; 30 ft for lots 75 ft wide or greater (2 stories) tall and the front setback is 35 ft, with the conditions listed below (Arcadia code, read October 2026).
Key points
- Maximum building height: 25 ft for lots less than 75 ft wide; 30 ft for lots 75 ft wide or greater (lot width)
- Maximum number of stories: 2 stories
- Minimum front setback: 35 ft (Or the average of the two nearest developed lots, if greater.)
- Minimum side setback: 10 ft or 10% of lot width, whichever is greater (Interior side, first or single story.)
- Minimum rear setback: 35 ft (First and second stories. Add 1 ft per story for each 10 ft of lot depth over 150 ft.)
- Maximum lot coverage: 45% (1-story dwellings)
- Maximum density: 1 unit per lot (Except as allowed for accessory dwelling units.)
R-0 (Single-Family Residential) is a zoning district in Arcadia. Every value below was read from the Arcadia Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.
Development standards in R-0
The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.
| Maximum building height | 25 ft for lots less than 75 ft wide; 30 ft for lots 75 ft wide or greater Applies: lot width § 9102.01.030 · code textTable row “Maximum Height”, column “R-0”: 25 ft for lots with less than 75-foot lot width 30 ft for lots with 75-foot width or greater |
|---|---|
| Maximum number of stories | 2 stories § 9102.01.030 · code textTable row “Maximum Number of Stories”, column “R-0”: 2 stories |
| Minimum front setback | 35 ft Applies: Or the average of the two nearest developed lots, if greater. § 9102.01.030 · code textTable row “Front”, column “R-0”: 35 ft |
| Minimum side setback | 10 ft or 10% of lot width, whichever is greater Applies: Interior side, first or single story. § 9102.01.030 · code textTable row “Interior”, column “R-0”: 10 ft or 10% of the lot width, whichever is greater |
| Minimum rear setback | 35 ft Applies: First and second stories. Add 1 ft per story for each 10 ft of lot depth over 150 ft. § 9102.01.030 · code textTable row “Rear - first or single story”, column “R-0”: 35 ft |
| Maximum lot coverage | 45% Applies: 1-story dwellings § 9102.01.030 · code textTable row “1-story dwellings”, column “R-0”: 45% |
| Maximum density | 1 unit per lot Applies: Except as allowed for accessory dwelling units. § 9102.01.030 · code textTable row “Maximum Density”, column “R-0”: 1 unit per lot |
Uses in R-0
Uses the code's use tables allow in R-0, or allow with a permit. Each links to its page with the code section.
- Single-family home — Allowed
- Residential care home (7 or more) — Allowed
- Child care center — Needs a conditional use permit
- Private school — Needs a conditional use permit — see note
When a different number applies
The code sets other values for particular lots, buildings or locations in R-0:
- Minimum side setback: 15 ft or 20% of lot width, whichever is greater — second story § 9102.01.030
- Minimum rear setback: 15 ft — Attached garage, one story and up to 16 ft high, on a corner or reverse corner lot. § 9102.01.040
- Maximum lot coverage: 35% — 2-story dwellings § 9102.01.030
Not on this page
We did not find a general lot size, FAR limit for R-0 in the zoning tables we read. The code may still set one elsewhere — check the Arcadia Municipal Code.
Other Arcadia zoning districts
Who this affects
Frequently asked questions
What is the maximum building height in Arcadia's R-0 zone?
25 ft for lots less than 75 ft wide; 30 ft for lots 75 ft wide or greater (lot width) — Arcadia Municipal Code § 9102.01.030.
What is the maximum number of stories in Arcadia's R-0 zone?
2 stories — Arcadia Municipal Code § 9102.01.030.
What is the minimum front setback in Arcadia's R-0 zone?
35 ft (or the average of the two nearest developed lots, if greater) — Arcadia Municipal Code § 9102.01.030.
What is the minimum side setback in Arcadia's R-0 zone?
10 ft or 10% of lot width, whichever is greater (interior side, first or single story) — Arcadia Municipal Code § 9102.01.030.
What is the minimum rear setback in Arcadia's R-0 zone?
35 ft (first and second stories. Add 1 ft per story for each 10 ft of lot depth over 150 ft) — Arcadia Municipal Code § 9102.01.030.
General information, not legal advice.
Ask about an Arcadia property in R-0
Ask GoCodebook what you can build at a specific address and get an answer that cites the section.
Ask your question