In Arcata's IL zone, buildings can be up to 45 ft tall, the front setback is 10 ft and the minimum lot size is 6,000 sf (Arcata code, read October 2026).
Key points
- Maximum building height: 45 ft
- Minimum front setback: 10 ft
- Minimum side setback: 10 ft
- Minimum rear setback: 10 ft
- Minimum lot size: 6,000 sf
- Maximum floor area ratio (FAR): 1.50
- Maximum density: 15 units per acre (The code gives a range of 7.26 to 15 units per acre)
IL is a zoning district in Arcata. Every value below was read from the Arcata Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.
Development standards in IL
The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.
| Maximum building height | 45 ft § 9.26.050 · code textTable row “Maximum height”, column “IL Zone Requirement”: 45 ft |
|---|---|
| Minimum front setback | 10 ft § 9.26.050 · code textTable row “Front”, column “IL Zone Requirement”: 10 ft |
| Minimum side setback | 10 ft § 9.26.050 · code textTable row “Side - Interior (each)”, column “IL Zone Requirement”: 20 ft abutting to a residential zone; 10 ft required otherwise |
| Minimum rear setback | 10 ft § 9.26.050 · code textTable row “Rear”, column “IL Zone Requirement”: 20 ft abutting to a residential zone; 10 ft required otherwise |
| Minimum lot size | 6,000 sf § 9.26.040 · code textTable row “IL”, column “Minimum Lot Area”: 6,000 sf |
| Maximum floor area ratio (FAR) | 1.50 § 9.26.050 · code textTable row “Maximum FAR”, column “IL Zone Requirement”: 1.50 |
| Maximum density | 15 units per acre Applies: The code gives a range of 7.26 to 15 units per acre § 9.26.040 · code textTable row “IL”, column “Maximum Density”: 7.26 to 15 units per acre |
When a different number applies
The code sets other values for particular lots, buildings or locations in IL:
- Minimum side setback: 20 ft — abutting to a residential zone § 9.26.050
- Minimum rear setback: 20 ft — abutting to a residential zone § 9.26.050
Not on this page
We did not find a general stories, lot coverage limit for IL in the zoning tables we read. The code may still set one elsewhere — check the Arcata Municipal Code.
Other Arcata zoning districts
Who this affects
Frequently asked questions
What is the maximum building height in Arcata's IL zone?
45 ft — Arcata Municipal Code § 9.26.050.
What is the minimum front setback in Arcata's IL zone?
10 ft — Arcata Municipal Code § 9.26.050.
What is the minimum side setback in Arcata's IL zone?
10 ft — Arcata Municipal Code § 9.26.050.
What is the minimum rear setback in Arcata's IL zone?
10 ft — Arcata Municipal Code § 9.26.050.
What is the minimum lot size in Arcata's IL zone?
6,000 sf — Arcata Municipal Code § 9.26.040.