In Atwater's R-1-8 zone, generally buildings can be up to 35 ft tall and the front setback is 20 ft, with the conditions listed below (Atwater code, read October 2026).

Key points

  • Maximum building height: 35 ft (may be exceeded if the further conditions the code lists after this limit are met)
  • Minimum front setback: 20 ft
  • Minimum side setback: 5 ft
  • Minimum rear setback: 20 ft
  • Maximum density: 1 unit per 8,000 sq ft

R-1-8 is a zoning district in Atwater. Every value below was read from the Atwater Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in R-1-8

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
Applies: may be exceeded if the further conditions the code lists after this limit are met
§ 17.16.060 · code text
No building constructed in this zone shall exceed a height of 35 feet unless the following has occurred:
Minimum front setback
20 ft
§ 17.16.050 · code text
Table row “Minimum Front yard Setback (exterior)”, column “R-1-8”: 20
Minimum side setback
5 ft
§ 17.16.050 · code text
Table row “Minimum Side yard Setback (interior)”, column “R-1-8”: 5
Minimum rear setback
20 ft
§ 17.16.050 · code text
Table row “Minimum Rear yard Setback”, column “R-1-8”: 20
Maximum density
1 unit per 8,000 sq ft
§ 17.16.050 · code text
Table row “Minimum Lot Area per dwelling unit (sq. ft.)”, column “R-1-8”: 8,000

Not on this page

We did not find a general stories, lot size, lot coverage, FAR limit for R-1-8 in the zoning tables we read. The code may still set one elsewhere — check the Atwater Municipal Code.

Other Atwater zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Atwater's R-1-8 zone?

35 ft (may be exceeded if the further conditions the code lists after this limit are met) — Atwater Municipal Code § 17.16.060.

What is the minimum front setback in Atwater's R-1-8 zone?

20 ft — Atwater Municipal Code § 17.16.050.

What is the minimum side setback in Atwater's R-1-8 zone?

5 ft — Atwater Municipal Code § 17.16.050.

What is the minimum rear setback in Atwater's R-1-8 zone?

20 ft — Atwater Municipal Code § 17.16.050.

What is the maximum density in Atwater's R-1-8 zone?

1 unit per 8,000 sq ft — Atwater Municipal Code § 17.16.050.

General information, not legal advice.