Skip to content

Avenal · Zoning · M-2

Avenal M-2 zoning: height, setbacks and lot size

In Avenal's M-2 zone, buildings can be up to no maximum tall and the front setback is 25 ft (Avenal code, read October 2026).

Key points

  • Maximum building height: no maximum
  • Minimum front setback: 25 ft
  • Minimum rear setback: 0 ft
  • Maximum lot coverage: 75%

M-2 (Heavy Industrial) is a zoning district in Avenal. Every value below was read from the Avenal Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in M-2

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
no maximum
§ 9.32.080 · code text
There is no maximum structure height.
Minimum front setback
25 ft
§ 9.32.060 · code text
The front building setback area shall be a minimum of 25 feet, except as modified by (F.).
Minimum rear setback
0 ft
§ 9.32.060 · code text
There is no rear building setback area.
Maximum lot coverage
75%
§ 9.32.050 · code text
The maximum building coverage of a lot shall be 75 percent.

When a different number applies

The code sets other values for particular lots, buildings or locations in M-2:

  • Maximum building height: 50 ft — when the structure is adjacent to existing or zoned residential uses § 9.32.080
  • Minimum front setback: 55 ft — from the legal centerline of any existing or proposed local street or minor collector § 9.32.060
  • Minimum front setback: 70 ft — from the legal centerline of any existing or proposed secondary highway or major collector street § 9.32.060
  • Minimum front setback: 80 ft — from the legal centerline of any existing or proposed primary highway or arterial street § 9.32.060

Not on this page

We did not find a general stories, side setback, lot size, FAR, density limit for M-2 in the zoning tables we read. The code may still set one elsewhere — check the Avenal Municipal Code.

Other Avenal zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Avenal's M-2 zone?

no maximum — Avenal Municipal Code § 9.32.080.

What is the minimum front setback in Avenal's M-2 zone?

25 ft — Avenal Municipal Code § 9.32.060.

What is the minimum rear setback in Avenal's M-2 zone?

0 ft — Avenal Municipal Code § 9.32.060.

What is the maximum lot coverage in Avenal's M-2 zone?

75% — Avenal Municipal Code § 9.32.050.

General information, not legal advice.

Ask about an Avenal property in M-2

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Avenal