What Beaumont's code says

Beaumont code What Beaumont's code adds
Brightness or color limit
  • At most 2,250 lumens (or equivalent).
    Applies: Each fully shielded fixture in the Residential Lighting Zone.
    § 8.50.060 · code text
    a. Fully shielded: 2,250 lumens (or equivalent) maximum;
  • At most 825 lumens (or equivalent).
    Applies: Each shielded fixture in the Residential Lighting Zone.
    § 8.50.060 · code text
    b. Shielded: 825 lumens (or equivalent) maximum;
Fixture height
  • At most 16 feet high.
    Applies: Pole-mounted lights in the Residential Lighting Zone; also no more than 40% of the distance from the property line, whichever is lower.
    § 8.50.060 · code text
    Lights mounted on poles or structures intended primarily for mounting lights shall not exceed a mounting height of 40 percent of the horizontal distance of the light pole from the property line, up to a maximum of 16 feet high, whichever is lower;
  • No higher than the roof eave.
    Applies: Lighting attached to single-family homes.
    § 8.50.060 · code text
    except that lighting attached to single family residences shall not exceed the height of the roof eave.
Shielding
  • Partly shielded fixtures are not allowed.
    Applies: Residential Lighting Zone.
    § 8.50.060 · code text
    c. Partly shielded: None permitted;
  • Unshielded fixtures are allowed only for low-voltage (24 volts or less) landscape lighting.
    Applies: Residential Lighting Zone.
    § 8.50.060 · code text
    d. Unshielded: Low voltage (24 volts or less) landscaping lighting only;
  • Fixtures must be permanently installed so they stay shielded.
    Applies: Outdoor lighting fixtures; low-voltage landscape lighting may use flexible or adjustable mounts.
    § 8.50.060 · code text
    Outdoor lighting fixtures shall be permanently installed so as to maintain the shielding requirements, except that low voltage landscaping lighting may use flexible or adjustable mounting systems.
  • Shield, filter, redirect, replace with a less intense light source, or remove the light.
    Applies: A non-conforming fixture the Planning Director finds causes light trespass; within 10 days of that finding.
    § 8.50.100 · code text
    the responsible party shall shield, filter, redirect or replace the light with a less intense light source, or remove the light to eliminate the light trespass.

Who this affects

HomeownersContractorsDesigners

Frequently asked questions

What are the outdoor lighting rules for homes in Beaumont?

Beaumont's code: Partly shielded fixtures are not allowed. (Residential Lighting Zone.) (§ 8.50.060); At most 16 feet high. (Pole-mounted lights in the Residential Lighting Zone; also no more than 40% of the distance from the property line, whichever is lower.) (§ 8.50.060).

General information, not legal advice.

Ask about a specific Beaumont property

Ask GoCodebook how Beaumont's outdoor lighting rules apply to your situation and get an answer that cites the section.

Ask your question

More on building on your lot in Beaumont