In Calexico's R-1 zone, buildings can be up to 35 ft (2 stories) tall, the front setback is 25 ft and the minimum lot size is 6,000 sq ft (Calexico code, read October 2026).

Key points

  • Maximum building height: 35 ft
  • Maximum number of stories: 2 stories
  • Minimum front setback: 25 ft
  • Minimum side setback: 5 ft
  • Minimum rear setback: 20 ft
  • Minimum lot size: 6,000 sq ft
  • Maximum lot coverage: 40%
  • Maximum density: 1.1 to 5.0 units per net acre (The code sets a range: at least 1.1, at most 5.0.)

R-1 is a zoning district in Calexico. Every value below was read from the Calexico Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in R-1

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
§ 17.03.120 · code text
Table row “10. Building and structure height (in feet)”, column “R-1”: 35 feet or 2 stories, whichever is less
Maximum number of stories
2 stories
§ 17.03.120 · code text
Table row “10. Building and structure height (in feet)”, column “R-1”: 35 feet or 2 stories, whichever is less
Minimum front setback
25 ft
§ 17.03.120 · code text
Table row “5. Front yard setback”, column “R-1”: 25
Minimum side setback
5 ft
§ 17.03.120 · code text
Table row “6. Side yard setback each side (in feet)”, column “R-1”: 5
Minimum rear setback
20 ft
§ 17.03.120 · code text
Table row “8. Rear setback”, column “R-1”: 20
Minimum lot size
6,000 sq ft
§ 17.03.120 · code text
Table row “2. Net lot area (in square feet)”, column “R-1”: 6,000
Maximum lot coverage
40%
§ 17.03.120 · code text
Table row “9. Lot coverage, maximum”, column “R-1”: 40%
Maximum density
1.1 to 5.0 units per net acre
Applies: The code sets a range: at least 1.1, at most 5.0.
§ 17.03.120 · code text
Table row “1. Density-maximum units per net acre”, column “R-1”: 1.1—5.0

Uses in R-1

Uses the code's use tables allow in R-1, or allow with a permit. Each links to its page with the code section.

Not on this page

We did not find a general FAR limit for R-1 in the zoning tables we read. The code may still set one elsewhere — check the Calexico Municipal Code.

Other Calexico zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Calexico's R-1 zone?

35 ft — Calexico Municipal Code § 17.03.120.

What is the maximum number of stories in Calexico's R-1 zone?

2 stories — Calexico Municipal Code § 17.03.120.

What is the minimum front setback in Calexico's R-1 zone?

25 ft — Calexico Municipal Code § 17.03.120.

What is the minimum side setback in Calexico's R-1 zone?

5 ft — Calexico Municipal Code § 17.03.120.

What is the minimum rear setback in Calexico's R-1 zone?

20 ft — Calexico Municipal Code § 17.03.120.

General information, not legal advice.

Ask about a Calexico property in R-1

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Calexico