Skip to content

Calimesa · Zoning · B-P

Calimesa B-P zoning: height, setbacks and lot size

In Calimesa's B-P zone, generally buildings can be up to 50 ft (3 stories) tall, the front setback is 15 ft and the minimum lot size is 1 ac., with the conditions listed below (Calimesa code, read October 2026).

Key points

  • Maximum building height: 50 ft (The code gives this limit as 3 stories or 50 ft)
  • Maximum number of stories: 3 stories (The code gives this limit as 3 stories or 50 ft)
  • Minimum front setback: 15 ft (Collector and Local streets; building setback)
  • Minimum side setback: 0 ft (30 ft where the property adjoins a parcel zoned or planned for residential use, with a landscaping buffer)
  • Minimum rear setback: 0 ft (30 ft where the property adjoins a parcel zoned or planned for residential use, with a landscaping buffer)
  • Minimum lot size: 1 ac.
  • Maximum floor area ratio (FAR): 0.50

B-P is a zoning district in Calimesa. Every value below was read from the Calimesa Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in B-P

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
50 ft
Applies: The code gives this limit as 3 stories or 50 ft
§ 18.30.040 · code text
Table row “Maximum height for buildings and structures”, column “B-P”: 3 stories or 50'
Maximum number of stories
3 stories
Applies: The code gives this limit as 3 stories or 50 ft
§ 18.30.040 · code text
Table row “Maximum height for buildings and structures”, column “B-P”: 3 stories or 50'
Minimum front setback
15 ft
Applies: Collector and Local streets; building setback
§ 18.30.040 · code text
Buildings and structures shall be located no closer than 15 feet of the property line adjacent to the public right-of-way.
Minimum side setback
0 ft
Applies: 30 ft where the property adjoins a parcel zoned or planned for residential use, with a landscaping buffer
§ 18.30.040 · code text
Side Yard Setback. There shall be no required side yard except where the property adjoins a parcel zoned or shown on the general plan land use map for residential use, in which case a minimum building setback of 30 feet shall be maintained and a buffer of landscaping shall be placed adjacent to the property line in accordance with the provisions of CMC § 18.70.140(A) .
Minimum rear setback
0 ft
Applies: 30 ft where the property adjoins a parcel zoned or planned for residential use, with a landscaping buffer
§ 18.30.040 · code text
Rear Yard Setback. There shall be no required rear yard except where the property adjoins a parcel zoned or shown on the general plan land use map for residential use, in which case a minimum building setback of 30 feet shall be maintained and a buffer of landscaping shall be placed adjacent to the property line in accordance with the provisions of CMC § 18.70.140(A) .
Minimum lot size
1 ac.
§ 18.30.040 · code text
Table row “Minimum site area (net)”, column “B-P”: 1 ac.
Maximum floor area ratio (FAR)
0.50
§ 18.30.040 · code text
Table row “Maximum floor area ratio”, column “B-P”: 0.50

Uses in B-P

Uses the code's use tables allow in B-P, or allow with a permit. Each links to its page with the code section.

When a different number applies

The code sets other values for particular lots, buildings or locations in B-P:

  • Minimum front setback: 20 ft — Major and Secondary Arterials or Freeway; building setback § 18.30.040
  • Minimum side setback: 30 ft — where the property adjoins a parcel zoned or shown on the general plan land use map for residential use § 18.30.040
  • Minimum rear setback: 30 ft — where the property adjoins a parcel zoned or shown on the general plan land use map for residential use § 18.30.040

Not on this page

We did not find a general lot coverage, density limit for B-P in the zoning tables we read. The code may still set one elsewhere — check the Calimesa Municipal Code.

Other Calimesa zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Calimesa's B-P zone?

50 ft (the code gives this limit as 3 stories or 50 ft) — Calimesa Municipal Code § 18.30.040.

What is the maximum number of stories in Calimesa's B-P zone?

3 stories (the code gives this limit as 3 stories or 50 ft) — Calimesa Municipal Code § 18.30.040.

What is the minimum front setback in Calimesa's B-P zone?

15 ft (collector and Local streets; building setback) — Calimesa Municipal Code § 18.30.040.

What is the minimum side setback in Calimesa's B-P zone?

0 ft (30 ft where the property adjoins a parcel zoned or planned for residential use, with a landscaping buffer) — Calimesa Municipal Code § 18.30.040.

What is the minimum rear setback in Calimesa's B-P zone?

0 ft (30 ft where the property adjoins a parcel zoned or planned for residential use, with a landscaping buffer) — Calimesa Municipal Code § 18.30.040.

General information, not legal advice.

Ask about a Calimesa property in B-P

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Calimesa