Skip to content

Chino Hills · Zoning · UHDH

Chino Hills UHDH zoning: height, setbacks and lot size

In Chino Hills's UHDH zone, generally buildings can be up to 70 ft tall and the minimum lot size is 4 acres, with the conditions listed below (Chino Hills code, read October 2026).

Key points

  • Maximum building height: 70 ft (To the roofline)
  • Minimum side setback: 10 ft (Interior side yard)
  • Minimum lot size: 4 acres (Minimum project area for a development)
  • Maximum floor area ratio (FAR): 2.25
  • Maximum density: 93 du/ac

UHDH (Urban High Density Housing) is a zoning district in Chino Hills. Every value below was read from the Chino Hills Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in UHDH

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
70 ft
Applies: To the roofline
§ 16.15.040 · code text
Table row “D. Maximum Building Height”, column “Minimum Required”: 70 ft. to roofline, 80 ft. to architectural features
Minimum side setback
10 ft
Applies: Interior side yard
§ 16.15.040 · code text
Table row “(4) Interior Side”, column “Minimum Required”: 10 ft.
Minimum lot size
4 acres
Applies: Minimum project area for a development
§ 16.15.040 · code text
Table row “A. Minimum Lot Size Development Minimum Project Area”, column “Minimum Required”: 4 acres
Maximum floor area ratio (FAR)
2.25
§ 16.15.040 · code text
Table row “E. Maximum FAR”, column “Minimum Required”: FAR 2.25
Maximum density
93 du/ac
§ 16.15.040 · code text
Residential density in the UHDH zone shall be built at a minimum of thirty (30) du/ac, with a maximum of ninety-three (93) du/ac.

When a different number applies

The code sets other values for particular lots, buildings or locations in UHDH:

  • Maximum building height: 80 ft — to architectural features § 16.15.040

Not on this page

We did not find a general stories, front setback, rear setback, lot coverage limit for UHDH in the zoning tables we read. The code may still set one elsewhere — check the Chino Hills Municipal Code.

Other Chino Hills zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Chino Hills's UHDH zone?

70 ft (to the roofline) — Chino Hills Municipal Code § 16.15.040.

What is the minimum side setback in Chino Hills's UHDH zone?

10 ft (interior side yard) — Chino Hills Municipal Code § 16.15.040.

What is the minimum lot size in Chino Hills's UHDH zone?

4 acres (minimum project area for a development) — Chino Hills Municipal Code § 16.15.040.

What is the maximum floor area ratio (far) in Chino Hills's UHDH zone?

2.25 — Chino Hills Municipal Code § 16.15.040.

What is the maximum density in Chino Hills's UHDH zone?

93 du/ac — Chino Hills Municipal Code § 16.15.040.

General information, not legal advice.

Ask about a Chino Hills property in UHDH

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Chino Hills