In Chino's MU 20 zone, generally buildings can be up to 45 feet (3 stories) tall, the front setback is 0 feet and the minimum lot size is 10,000 sq. ft., with the conditions listed below (Chino code, read October 2026).

Key points

  • Maximum building height: 45 feet
  • Maximum number of stories: 3 stories
  • Minimum front setback: 0 feet (Where the lot abuts a residential parcel, the setback is the same as that residential use requires.)
  • Minimum lot size: 10,000 sq. ft.
  • Maximum lot coverage: 80%
  • Maximum floor area ratio (FAR): 1.0
  • Maximum density: 20 DU/AC

MU 20 is a zoning district in Chino. Every value below was read from the Chino Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in MU 20

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
45 feet
§ 20.05.040 · code text
Table row “Feet”, column “MU 20”: 45 feet
Maximum number of stories
3 stories
§ 20.05.040 · code text
Table row “Stories”, column “MU 20”: 3
Minimum front setback
0 feet
Applies: Where the lot abuts a residential parcel, the setback is the same as that residential use requires.
§ 20.05.040 · code text
Table row “Front”, column “MU 20”: 0 feet
Minimum lot size
10,000 sq. ft.
§ 20.05.040 · code text
Table row “Lot Area, Minimum”, column “MU 20”: 10,000 sq. ft.
Maximum lot coverage
80%
§ 20.05.040 · code text
Table row “Maximum Lot Coverage”, column “MU 20”: 80%
Maximum floor area ratio (FAR)
1.0
§ 20.05.040 · code text
Table row “Floor Area Ratio (FAR)”, column “MU 20”: 1.0
Maximum density
20 DU/AC
§ 20.05.040 · code text
Table row “Density , Maximum”, column “MU 20”: 20 DU/AC

Not on this page

We did not find a general side setback, rear setback limit for MU 20 in the zoning tables we read. The code may still set one elsewhere — check the Chino Municipal Code.

Other Chino zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Chino's MU 20 zone?

45 feet — Chino Municipal Code § 20.05.040.

What is the maximum number of stories in Chino's MU 20 zone?

3 stories — Chino Municipal Code § 20.05.040.

What is the minimum front setback in Chino's MU 20 zone?

0 feet (where the lot abuts a residential parcel, the setback is the same as that residential use requires) — Chino Municipal Code § 20.05.040.

What is the minimum lot size in Chino's MU 20 zone?

10,000 sq. ft. — Chino Municipal Code § 20.05.040.

What is the maximum lot coverage in Chino's MU 20 zone?

80% — Chino Municipal Code § 20.05.040.

General information, not legal advice.

Ask about a Chino property in MU 20

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Chino