Skip to content

Cupertino · Zoning · R-3

Cupertino R-3 zoning: height, setbacks and lot size

In Cupertino's R-3 zone, generally buildings can be up to 30 ft (2 stories) tall and the front setback is 20 ft, with the conditions listed below (Cupertino code, read October 2026).

Key points

  • Maximum building height: 30 ft (Projects with up to four units)
  • Maximum number of stories: 2 stories (Projects with up to four units)
  • Minimum front setback: 20 ft (Projects with up to four units; first floor)
  • Minimum side setback: 6 ft (Projects with up to four units, first floor)
  • Minimum rear setback: 20 ft or 20% of lot depth, whichever is greater (main building may be 10 ft from the rear line if usable rear area is 20 times the lot width)
  • Maximum lot coverage: 50% (Projects with up to four units; of net lot area, unless inconsistent with Govt. Section 65913.11)

R-3 (Multiple-Family Residential) is a zoning district in Cupertino. Every value below was read from the Cupertino Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in R-3

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
30 ft
Applies: Projects with up to four units
§ 19.36.070 · code text
Table row “B. Maximum Height”, column “Projects with up to four units”: Limited to two stories (not to exceed 30 feet)
Maximum number of stories
2 stories
Applies: Projects with up to four units
§ 19.36.070 · code text
Table row “B. Maximum Height”, column “Projects with up to four units”: Limited to two stories (not to exceed 30 feet)
Minimum front setback
20 ft
Applies: Projects with up to four units; first floor
§ 19.36.070 · code text
Table row “1. Front-yard”, column “First Floor”: 20 feet
Minimum side setback
6 ft
Applies: Projects with up to four units, first floor
§ 19.36.070 · code text
Table row “i. Interior side”, column “First Floor”: 6 feet
Minimum rear setback
20 ft or 20% of lot depth, whichever is greater
Applies: main building may be 10 ft from the rear line if usable rear area is 20 times the lot width
§ 19.36.070 · code text
Table row “3. Rear-yard”, column “First Floor”: 20 feet or 20% of the lot depth, whichever is greater. Main building may encroach as close as 10 feet to rear lot line if a usable rear-yard setback area of not less than twenty times the width of the lot is maintained.
Maximum lot coverage
50%
Applies: Projects with up to four units; of net lot area, unless inconsistent with Govt. Section 65913.11
§ 19.36.070 · code text
Table row “A. Maximum Lot Coverage”, column “Projects with up to four units”: 50% of net lot area, unless inconsistent with Govt. Section 65913.11

When a different number applies

The code sets other values for particular lots, buildings or locations in R-3:

  • Minimum front setback: 35 ft — Projects with five or more units, first floor, when located on property abutting an arterial or major collector; measured from face of street curb § 19.36.070
  • Minimum front setback: 35 ft — Projects with five or more units, upper floors, floors 2 and 3, when located on property abutting an arterial or major collector; measured from face of street curb § 19.36.070
  • Minimum side setback: 10 ft — Projects with up to four units, second floor or portions of building 24 feet or higher § 19.36.070
  • Minimum side setback: 10 ft — Projects with five or more units, first floor § 19.36.070
  • Minimum side setback: 12 ft — Projects with five or more units, upper floors § 19.36.070
  • Minimum rear setback: 10 ft — Main building may stand this close if the usable rear-yard area is at least 20 times the lot width § 19.36.070
  • Minimum rear setback: 10 ft additional — Projects with five or more units, upper floors, additional setback for floors more than one story higher than any adjacent primary residential structures § 19.36.070
  • Maximum lot coverage: 55% — Projects with five or more units; of net lot area, unless inconsistent with Govt. Section 65913.11 § 19.36.070

Not on this page

We did not find a general lot size, FAR, density limit for R-3 in the zoning tables we read. The code may still set one elsewhere — check the Cupertino Municipal Code.

Other Cupertino zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Cupertino's R-3 zone?

30 ft (projects with up to four units) — Cupertino Municipal Code § 19.36.070.

What is the maximum number of stories in Cupertino's R-3 zone?

2 stories (projects with up to four units) — Cupertino Municipal Code § 19.36.070.

What is the minimum front setback in Cupertino's R-3 zone?

20 ft (projects with up to four units; first floor) — Cupertino Municipal Code § 19.36.070.

What is the minimum side setback in Cupertino's R-3 zone?

6 ft (projects with up to four units, first floor) — Cupertino Municipal Code § 19.36.070.

What is the minimum rear setback in Cupertino's R-3 zone?

20 ft or 20% of lot depth, whichever is greater (main building may be 10 ft from the rear line if usable rear area is 20 times the lot width) — Cupertino Municipal Code § 19.36.070.

General information, not legal advice.

Ask about a Cupertino property in R-3

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Cupertino