Diamond Bar · Zoning · RH
Diamond Bar RH zoning: height, setbacks and lot size
In Diamond Bar's RH zone, generally buildings can be up to 35 ft tall, the front setback is 20 ft and the minimum lot size is 5,000 sq. ft., with the conditions listed below (Diamond Bar code, read October 2026).
Key points
- Maximum building height: 35 ft
- Minimum front setback: 20 ft
- Minimum side setback: 5 ft (Plus 1 ft. for each story over 2.)
- Minimum rear setback: 20 ft (From the property line or buildable pad on a descending slope, whichever is applicable.)
- Minimum lot size: 5,000 sq. ft. (Minimum area for parcels proposed in new subdivisions; exceptions and alternative ownership parcel sizes are described in footnote (1).)
- Maximum lot coverage: 30%
- Maximum density: 20 dwellings per gross acre
RH is a zoning district in Diamond Bar. Every value below was read from the Diamond Bar Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.
Development standards in RH
The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.
| Maximum building height | 35 ft See note 5 below the table in the code. § 22.08.040 · code textTable row “Height limit (5)”, column “RH”: 35 ft. Note 5: Maximum allowable height for structures. See section 22.16.060 (Height measurement and height limit exceptions). |
|---|---|
| Minimum front setback | 20 ft See note 3 below the table in the code. § 22.08.040 · code textTable row “Front (3)”, column “RH”: 20 ft. Note 3: Front setbacks listed are minimums. For single-family detached tract development, a minimum five-foot setback variation for adjacent residential units is required. |
| Minimum side setback | 5 ft Applies: Plus 1 ft. for each story over 2. See note 4 below the table in the code. § 22.08.040 · code textTable row “Sides (each) (4)”, column “RH”: 5 ft.; plus 1 ft. for each story over 2 Note 4: See section 22.68.030(b)(2) for nonconforming side setbacks and distance separations to dwelling units. |
| Minimum rear setback | 20 ft Applies: From the property line or buildable pad on a descending slope, whichever is applicable. § 22.08.040 · code textTable row “Rear”, column “RH”: 20 ft. from the property line or buildable pad on a descending slope whichever is applicable |
| Minimum lot size | 5,000 sq. ft. Applies: Minimum area for parcels proposed in new subdivisions; exceptions and alternative ownership parcel sizes are described in footnote (1). See note 1 below the table in the code. § 22.08.040 · code textTable row “Minimum lot area (1)”, column “RH”: 5,000 sq. ft. Note 1: Minimum area for parcels proposed in new subdivisions, except as otherwise provided by section 22.08.050 (Minimum lot area), and chapter 22.22 (Hillside Management). Condominium, townhome, or planned development projects may be subdivided with smaller parcel sizes for ownership purposes, with the minimum lot area requirement determined through the subdivision review process, provided that the over |
| Maximum lot coverage | 30% § 22.08.040 · code textTable row “Lot Coverage”, column “RH”: 30 percent |
| Maximum density | 20 dwellings per gross acre See note 2 below the table in the code. § 22.08.040 · code textTable row “Residential density (2)”, column “RH”: 20 dwellings per gross acre Note 2: Maximum number of dwellings allowed for each specified unit of land. The approval of a conditional use permit within areas subject to section 22.22.040 (Hillside management—Density) may result in fewer dwelling units being allowed than the maximum density shown. See also chapter 22.18 (Affordable Housing Incentives/Density Bonus Provisions) for possible density bonuses. |
Uses in RH
Uses the code's use tables allow in RH, or allow with a permit. Each links to its page with the code section.
- Single-family home — Allowed
- Duplex — Allowed
- Child care center — Needs a conditional use permit
- Private school — Needs a conditional use permit
Not on this page
We did not find a general stories, FAR limit for RH in the zoning tables we read. The code may still set one elsewhere — check the Diamond Bar Municipal Code.
Other Diamond Bar zoning districts
Who this affects
Frequently asked questions
What is the maximum building height in Diamond Bar's RH zone?
35 ft — Diamond Bar Municipal Code § 22.08.040.
What is the minimum front setback in Diamond Bar's RH zone?
20 ft — Diamond Bar Municipal Code § 22.08.040.
What is the minimum side setback in Diamond Bar's RH zone?
5 ft (plus 1 ft. for each story over 2) — Diamond Bar Municipal Code § 22.08.040.
What is the minimum rear setback in Diamond Bar's RH zone?
20 ft (from the property line or buildable pad on a descending slope, whichever is applicable) — Diamond Bar Municipal Code § 22.08.040.
What is the minimum lot size in Diamond Bar's RH zone?
5,000 sq. ft. (minimum area for parcels proposed in new subdivisions; exceptions and alternative ownership parcel sizes are described in footnote (1)) — Diamond Bar Municipal Code § 22.08.040.
General information, not legal advice.
Ask about a Diamond Bar property in RH
Ask GoCodebook what you can build at a specific address and get an answer that cites the section.
Ask your question