Skip to content

Fairfax · Zoning · O-A

Fairfax O-A zoning: height, setbacks and lot size

In Fairfax's O-A zone, generally buildings can be up to 35 ft tall and the front setback is 6 ft, with the conditions listed below (Fairfax code, read October 2026).

Key points

  • Maximum building height: 35 ft
  • Minimum front setback: 6 ft (Building site slope not more than 10 percent; front and rear yards combined must be at least 25 feet.)
  • Minimum side setback: 5 ft (Building site slope not more than 10 percent; two side yards combined must be at least 15 feet.)
  • Minimum rear setback: 6 ft (Building site slope not more than 10 percent; front and rear yards combined must be at least 25 feet.)

O-A (OPEN AREA ZONE) is a zoning district in Fairfax. Every value below was read from the Fairfax Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in O-A

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
§ 17.128.060 · code text
Height regulations in the O-A zone are as follows: Except as otherwise permitted by variance, no structure shall be higher than 35 feet above natural grade.
Minimum front setback
6 ft
Applies: Building site slope not more than 10 percent; front and rear yards combined must be at least 25 feet.
§ 17.128.070 · code text
(1) A front and rear yard having a combined depth of not less than twenty-five feet but neither having a depth of less than six feet;
Minimum side setback
5 ft
Applies: Building site slope not more than 10 percent; two side yards combined must be at least 15 feet.
§ 17.128.070 · code text
(2) Two side yards having a combined width of not less than 15 feet, but neither yard having a width of less than five feet.
Minimum rear setback
6 ft
Applies: Building site slope not more than 10 percent; front and rear yards combined must be at least 25 feet.
§ 17.128.070 · code text
(1) A front and rear yard having a combined depth of not less than twenty-five feet but neither having a depth of less than six feet;

When a different number applies

The code sets other values for particular lots, buildings or locations in O-A:

  • Minimum rear setback: 12 ft — Building site slope more than 10 percent; front and rear yards combined must be at least 35 feet. § 17.128.070

Not on this page

We did not find a general stories, lot size, lot coverage, FAR, density limit for O-A in the zoning tables we read. The code may still set one elsewhere — check the Fairfax Municipal Code.

Other Fairfax zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Fairfax's O-A zone?

35 ft — Fairfax Municipal Code § 17.128.060.

What is the minimum front setback in Fairfax's O-A zone?

6 ft (building site slope not more than 10 percent; front and rear yards combined must be at least 25 feet) — Fairfax Municipal Code § 17.128.070.

What is the minimum side setback in Fairfax's O-A zone?

5 ft (building site slope not more than 10 percent; two side yards combined must be at least 15 feet) — Fairfax Municipal Code § 17.128.070.

What is the minimum rear setback in Fairfax's O-A zone?

6 ft (building site slope not more than 10 percent; front and rear yards combined must be at least 25 feet) — Fairfax Municipal Code § 17.128.070.

General information, not legal advice.

Ask about a Fairfax property in O-A

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Fairfax