Skip to content

Hercules · Zoning · CP

Hercules CP zoning: height, setbacks and lot size

In Hercules's CP zone, buildings can be up to 50 feet tall and the front setback is 20 ft (Hercules code, read October 2026).

Key points

  • Maximum building height: 50 feet
  • Minimum front setback: 20 ft
  • Minimum side setback: 20 ft
  • Minimum rear setback: 20 ft
  • Maximum floor area ratio (FAR): 0.10 to 1.00 (The code sets a range: at least 0.10, at most 1.00; parking structures with up to 3.00 FAR for the parking area are also allowed)

CP (Commercial Public Mixed-Use District) is a zoning district in Hercules. Every value below was read from the Hercules Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in CP

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
50 feet
§ 13-11.500 · code text
Table row “Building Height”, column “CP”: 50 feet
Minimum front setback
20 ft
See note 2 below the table in the code.
§ 13-11.500 · code text
Table row “Front (ft)”, column “CP”: 20 (2)
Note 2: Lesser setbacks may be accepted as part of an approved planned development plan.
Minimum side setback
20 ft
See note 2 below the table in the code.
§ 13-11.500 · code text
Table row “Side (ft)”, column “CP”: 20 (2)
Note 2: Lesser setbacks may be accepted as part of an approved planned development plan.
Minimum rear setback
20 ft
See note 2 below the table in the code.
§ 13-11.500 · code text
Table row “Rear (ft)”, column “CP”: 20 (2)
Note 2: Lesser setbacks may be accepted as part of an approved planned development plan.
Maximum floor area ratio (FAR)
0.10 to 1.00
Applies: The code sets a range: at least 0.10, at most 1.00; parking structures with up to 3.00 FAR for the parking area are also allowed
See note 1 below the table in the code.
§ 13-11.500 · code text
Table row “Range”, column “CP”: 0.10 to 1.00 (1)
Note 1: In addition, parking structure(s) with up to a 3.00 FAR for the parking area is allowed.

Not on this page

We did not find a general stories, lot size, lot coverage, density limit for CP in the zoning tables we read. The code may still set one elsewhere — check the Hercules Municipal Code.

Other Hercules zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Hercules's CP zone?

50 feet — Hercules Municipal Code § 13-11.500.

What is the minimum front setback in Hercules's CP zone?

20 ft — Hercules Municipal Code § 13-11.500.

What is the minimum side setback in Hercules's CP zone?

20 ft — Hercules Municipal Code § 13-11.500.

What is the minimum rear setback in Hercules's CP zone?

20 ft — Hercules Municipal Code § 13-11.500.

What is the maximum floor area ratio (far) in Hercules's CP zone?

0.10 to 1.00 (the code sets a range: at least 0.10, at most 1.00; parking structures with up to 3.00 FAR for the parking area are also allowed) — Hercules Municipal Code § 13-11.500.

General information, not legal advice.

Ask about a Hercules property in CP

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Hercules