Highland · Zoning · R-2
Highland R-2 zoning: height, setbacks and lot size
In Highland's R-2 zone, buildings can be up to 35 ft (2-1/2 stories) tall, the front setback is 20 ft and the minimum lot size is 7,200 sq ft (Highland code, read October 2026).
Key points
- Maximum building height: 35 ft
- Maximum number of stories: 2-1/2 stories
- Minimum front setback: 20 ft
- Minimum side setback: 5 ft and 10 ft (Two-story or taller parts need at least 10 ft (table note h))
- Minimum rear setback: 20 ft
- Minimum lot size: 7,200 sq ft
- Maximum lot coverage: 40%
- Maximum density: 12.0 DUs per gross acre
R-2 is a zoning district in Highland. Every value below was read from the Highland Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.
Development standards in R-2
The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.
| Maximum building height | 35 ft § 16.16.040 · code textTable row “10. Maximum height for buildings and structures”, column “R-2”: 35 ft. or 2-1/2 stories, whichever is greater |
|---|---|
| Maximum number of stories | 2-1/2 stories § 16.16.040 · code textTable row “10. Maximum height for buildings and structures”, column “R-2”: 35 ft. or 2-1/2 stories, whichever is greater |
| Minimum front setback | 20 ft § 16.16.040 · code textTable row “5. Minimum front yard setback”, column “R-2”: 20 ft. |
| Minimum side setback | 5 ft and 10 ft Applies: Two-story or taller parts need at least 10 ft (table note h) § 16.16.040 · code textTable row “6. Minimum interior side yard setback h”, column “R-2”: 5 ft. and 10 ft. |
| Minimum rear setback | 20 ft § 16.16.040 · code textTable row “8. Minimum rear yard setback i”, column “R-2”: 20 ft. |
| Minimum lot size | 7,200 sq ft § 16.16.040 · code textTable row “2. Minimum building site (net area in sq. ft.)”, column “R-2”: 7,200 |
| Maximum lot coverage | 40% § 16.16.040 · code textTable row “9. Maximum lot coverage”, column “R-2”: 40% |
| Maximum density | 12.0 DUs per gross acre § 16.16.040 · code textTable row “1. Maximum density (DUs per gross acre)”, column “R-2”: 12.0 |
Uses in R-2
Uses the code's use tables allow in R-2, or allow with a permit. Each links to its page with the code section.
- Single-family home — Needs a staff review permit
- Apartment building — Needs a conditional use permit
- Church or place of worship — Needs a conditional use permit
Not on this page
We did not find a general FAR limit for R-2 in the zoning tables we read. The code may still set one elsewhere — check the Highland Municipal Code.
Other Highland zoning districts
Who this affects
Frequently asked questions
What is the maximum building height in Highland's R-2 zone?
35 ft — Highland Municipal Code § 16.16.040.
What is the maximum number of stories in Highland's R-2 zone?
2-1/2 stories — Highland Municipal Code § 16.16.040.
What is the minimum front setback in Highland's R-2 zone?
20 ft — Highland Municipal Code § 16.16.040.
What is the minimum side setback in Highland's R-2 zone?
5 ft and 10 ft (two-story or taller parts need at least 10 ft (table note h)) — Highland Municipal Code § 16.16.040.
What is the minimum rear setback in Highland's R-2 zone?
20 ft — Highland Municipal Code § 16.16.040.
General information, not legal advice.
Ask about a Highland property in R-2
Ask GoCodebook what you can build at a specific address and get an answer that cites the section.
Ask your question