In Highland's R-2 zone, buildings can be up to 35 ft (2-1/2 stories) tall, the front setback is 20 ft and the minimum lot size is 7,200 sq ft (Highland code, read October 2026).

Key points

  • Maximum building height: 35 ft
  • Maximum number of stories: 2-1/2 stories
  • Minimum front setback: 20 ft
  • Minimum side setback: 5 ft and 10 ft (Two-story or taller parts need at least 10 ft (table note h))
  • Minimum rear setback: 20 ft
  • Minimum lot size: 7,200 sq ft
  • Maximum lot coverage: 40%
  • Maximum density: 12.0 DUs per gross acre

R-2 is a zoning district in Highland. Every value below was read from the Highland Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in R-2

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
§ 16.16.040 · code text
Table row “10. Maximum height for buildings and structures”, column “R-2”: 35 ft. or 2-1/2 stories, whichever is greater
Maximum number of stories
2-1/2 stories
§ 16.16.040 · code text
Table row “10. Maximum height for buildings and structures”, column “R-2”: 35 ft. or 2-1/2 stories, whichever is greater
Minimum front setback
20 ft
§ 16.16.040 · code text
Table row “5. Minimum front yard setback”, column “R-2”: 20 ft.
Minimum side setback
5 ft and 10 ft
Applies: Two-story or taller parts need at least 10 ft (table note h)
§ 16.16.040 · code text
Table row “6. Minimum interior side yard setback h”, column “R-2”: 5 ft. and 10 ft.
Minimum rear setback
20 ft
§ 16.16.040 · code text
Table row “8. Minimum rear yard setback i”, column “R-2”: 20 ft.
Minimum lot size
7,200 sq ft
§ 16.16.040 · code text
Table row “2. Minimum building site (net area in sq. ft.)”, column “R-2”: 7,200
Maximum lot coverage
40%
§ 16.16.040 · code text
Table row “9. Maximum lot coverage”, column “R-2”: 40%
Maximum density
12.0 DUs per gross acre
§ 16.16.040 · code text
Table row “1. Maximum density (DUs per gross acre)”, column “R-2”: 12.0

Uses in R-2

Uses the code's use tables allow in R-2, or allow with a permit. Each links to its page with the code section.

Not on this page

We did not find a general FAR limit for R-2 in the zoning tables we read. The code may still set one elsewhere — check the Highland Municipal Code.

Other Highland zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Highland's R-2 zone?

35 ft — Highland Municipal Code § 16.16.040.

What is the maximum number of stories in Highland's R-2 zone?

2-1/2 stories — Highland Municipal Code § 16.16.040.

What is the minimum front setback in Highland's R-2 zone?

20 ft — Highland Municipal Code § 16.16.040.

What is the minimum side setback in Highland's R-2 zone?

5 ft and 10 ft (two-story or taller parts need at least 10 ft (table note h)) — Highland Municipal Code § 16.16.040.

What is the minimum rear setback in Highland's R-2 zone?

20 ft — Highland Municipal Code § 16.16.040.