Skip to content

Kern County · Zoning · C-2

Kern County C-2 zoning: height, setbacks and lot size

In Kern County's C-2 zone, generally buildings can be up to 75 ft (6 stories) tall, the front setback is 40 ft and the minimum lot size is 7,500 sq ft, with the conditions listed below (Kern County code, read October 2026).

Key points

  • Maximum building height: 75 ft (Higher is allowed with 1 ft of setback from each street, alley and lot line per 3 ft above 6 stories or 75 ft)
  • Maximum number of stories: 6 stories (Higher is allowed with 1 ft of setback from each street, alley and lot line per 3 ft above 6 stories or 75 ft)
  • Minimum front setback: 40 ft (from the legal centerline of any existing or proposed public or private local street and access easements)
  • Minimum side setback: None required
  • Minimum rear setback: 20 ft
  • Minimum lot size: 7,500 sq ft

C-2 (General Commercial) is a zoning district in Kern County. Every value below was read from the Kern County Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in C-2

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
75 ft
Applies: Higher is allowed with 1 ft of setback from each street, alley and lot line per 3 ft above 6 stories or 75 ft
§ 19.32.080 · code text
Buildings and structures shall not exceed six (6) stories or seventy-five (75) feet, unless the building is set back from each street, alley, and lot line at least one (1) foot for each three (3) feet of height above six (6) stories or seventy-five (75) feet.
Maximum number of stories
6 stories
Applies: Higher is allowed with 1 ft of setback from each street, alley and lot line per 3 ft above 6 stories or 75 ft
§ 19.32.080 · code text
Buildings and structures shall not exceed six (6) stories or seventy-five (75) feet, unless the building is set back from each street, alley, and lot line at least one (1) foot for each three (3) feet of height above six (6) stories or seventy-five (75) feet.
Minimum front setback
40 ft
Applies: from the legal centerline of any existing or proposed public or private local street and access easements
§ 19.32.070 · code text
Forty (40) feet from the legal centerline of any existing or proposed public or private local street and access easements;
Minimum side setback
None required
§ 19.32.070 · code text
None required.
Minimum rear setback
20 ft
§ 19.32.070 · code text
There shall be a rear yard of not less than twenty (20) feet, except that no rear yard shall be required in the event that a public alley exists.
Minimum lot size
7,500 sq ft
§ 19.32.050 · code text
Except as otherwise provided in Chapter 19.58 of this title, no lot created within the C-2 district shall contain less than seven thousand five hundred (7,500) net square feet, excepting in the case of the conveyance to or from a governmental agency, public entity, public utility, community water company or mutual water company for public purposes, public utility purposes, or for rights-of-way or well sites.

When a different number applies

The code sets other values for particular lots, buildings or locations in C-2:

  • Maximum building height: 135 ft — absolute maximum; applies regardless of the additional setback allowance § 19.32.080
  • Maximum number of stories: 10 stories — absolute maximum; applies regardless of the additional setback allowance § 19.32.080
  • Minimum front setback: 45 ft — from the legal centerline of any existing or proposed secondary highway § 19.32.070
  • Minimum front setback: 55 ft — from the legal centerline of any existing or proposed major highway § 19.32.070
  • Minimum rear setback: None required — when a public alley exists § 19.32.070
  • Maximum density: 1 unit per 1,500 sq ft — when dwellings are permitted with a conditional use permit § 19.32.060

Not on this page

We did not find a general lot coverage, FAR, density limit for C-2 in the zoning tables we read. The code may still set one elsewhere — check the Kern County Municipal Code.

Other Kern County zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Kern County's C-2 zone?

75 ft (higher is allowed with 1 ft of setback from each street, alley and lot line per 3 ft above 6 stories or 75 ft) — Kern County Municipal Code § 19.32.080.

What is the maximum number of stories in Kern County's C-2 zone?

6 stories (higher is allowed with 1 ft of setback from each street, alley and lot line per 3 ft above 6 stories or 75 ft) — Kern County Municipal Code § 19.32.080.

What is the minimum front setback in Kern County's C-2 zone?

40 ft (from the legal centerline of any existing or proposed public or private local street and access easements) — Kern County Municipal Code § 19.32.070.

What is the minimum side setback in Kern County's C-2 zone?

None required — Kern County Municipal Code § 19.32.070.

What is the minimum rear setback in Kern County's C-2 zone?

20 ft — Kern County Municipal Code § 19.32.070.