La Quinta · Zoning · CP

La Quinta CP zoning: height, setbacks and lot size

In La Quinta's CP zone, buildings can be up to 35 ft (2 stories) tall, the side setback limit is 0 ft and the rear setback limit is 0 ft (La Quinta code, read October 2026).

Key points

  • Maximum building height: 35 ft
  • Maximum number of stories: 2 stories
  • Minimum side setback: 0 ft (Interior property lines within nonresidential districts only; larger setbacks apply next to residential districts.)
  • Minimum rear setback: 0 ft (Interior property lines within nonresidential districts only; larger setbacks apply next to residential districts.)
  • Maximum floor area ratio (FAR): 0.50

CP is a zoning district in La Quinta. Every value below was read from the La Quinta Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in CP

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
§ 9.90.040 · code text
Table row “Maximum building height (ft.) 1, 6, 7”, column “CP”: 35
Maximum number of stories
2 stories
§ 9.90.040 · code text
Table row “Maximum number of stories”, column “CP”: 2
Minimum side setback
0 ft
Applies: Interior property lines within nonresidential districts only; larger setbacks apply next to residential districts.
§ 9.90.040 · code text
Table row “Minimum setback from interior property lines within nonresidential districts”, column “CP”: 0
Minimum rear setback
0 ft
Applies: Interior property lines within nonresidential districts only; larger setbacks apply next to residential districts.
§ 9.90.040 · code text
Table row “Minimum setback from interior property lines within nonresidential districts”, column “CP”: 0
Maximum floor area ratio (FAR)
0.50
§ 9.90.040 · code text
Table row “Maximum floor area ratio (FAR) 2”, column “CP”: .50

Uses in CP

Uses the code's use tables allow in CP, or allow with a permit. Each links to its page with the code section.

Not on this page

We did not find a general front setback, lot size, lot coverage, density limit for CP in the zoning tables we read. The code may still set one elsewhere — check the La Quinta Municipal Code.

Other La Quinta zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in La Quinta's CP zone?

35 ft — La Quinta Municipal Code § 9.90.040.

What is the maximum number of stories in La Quinta's CP zone?

2 stories — La Quinta Municipal Code § 9.90.040.

What is the minimum side setback in La Quinta's CP zone?

0 ft (interior property lines within nonresidential districts only; larger setbacks apply next to residential districts) — La Quinta Municipal Code § 9.90.040.

What is the minimum rear setback in La Quinta's CP zone?

0 ft (interior property lines within nonresidential districts only; larger setbacks apply next to residential districts) — La Quinta Municipal Code § 9.90.040.

What is the maximum floor area ratio (far) in La Quinta's CP zone?

0.50 — La Quinta Municipal Code § 9.90.040.