Skip to content

Lomita · Zoning · NC

Lomita NC zoning: height, setbacks and lot size

In Lomita's NC zone, buildings can be up to 35 ft tall, the front setback is 0 ft and the minimum lot size is 5,000 sq ft (Lomita code, read October 2026).

Key points

  • Maximum building height: 35 ft
  • Minimum front setback: 0 ft
  • Minimum side setback: 0 ft
  • Minimum rear setback: 0 ft
  • Minimum lot size: 5,000 sq ft
  • Maximum floor area ratio (FAR): 1:1

NC is a zoning district in Lomita. Every value below was read from the Lomita Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in NC

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
§ 11-1.42.01 · code text
Table row “Building height, maximum”, column “NC”: 35'
Minimum front setback
0 ft
§ 11-1.42.01 · code text
Table row “Front and street side yard”, column “NC”: 0'-0"
Minimum side setback
0 ft
§ 11-1.42.01 · code text
Table row “Side yard”, column “NC”: 0'-0"
Minimum rear setback
0 ft
§ 11-1.42.01 · code text
Table row “Rear yard”, column “NC”: 0'-0"
Minimum lot size
5,000 sq ft
§ 11-1.42.01 · code text
Table row “Lot area, minimum”, column “NC”: 5,000 square feet
Maximum floor area ratio (FAR)
1:1
§ 11-1.42.01 · code text
Table row “Floor area ratio, maximum”, column “NC”: 1:1

Uses in NC

Uses the code's use tables allow in NC, or allow with a permit. Each links to its page with the code section.

When a different number applies

The code sets other values for particular lots, buildings or locations in NC:

  • Minimum side setback: 10 ft — Minimum side yard adjoining a residential zone § 11-1.42.01
  • Minimum rear setback: 10 ft — Minimum rear yard adjoining a residential zone § 11-1.42.01

Not on this page

We did not find a general stories, lot coverage, density limit for NC in the zoning tables we read. The code may still set one elsewhere — check the Lomita Municipal Code.

Other Lomita zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Lomita's NC zone?

35 ft — Lomita Municipal Code § 11-1.42.01.

What is the minimum front setback in Lomita's NC zone?

0 ft — Lomita Municipal Code § 11-1.42.01.

What is the minimum side setback in Lomita's NC zone?

0 ft — Lomita Municipal Code § 11-1.42.01.

What is the minimum rear setback in Lomita's NC zone?

0 ft — Lomita Municipal Code § 11-1.42.01.

What is the minimum lot size in Lomita's NC zone?

5,000 sq ft — Lomita Municipal Code § 11-1.42.01.

General information, not legal advice.

Ask about a Lomita property in NC

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.