Skip to content

Milpitas · Zoning · R1-10

Milpitas R1-10 zoning: height, setbacks and lot size

In Milpitas's R1-10 zone, generally buildings can be up to 30 ft tall, the front setback is 25 ft and the minimum lot size is 10,000 sf, with the conditions listed below (Milpitas code, read October 2026).

Key points

  • Maximum building height: 30 ft
  • Minimum front setback: 25 ft (40 ft where the property slope is 16% or more.)
  • Minimum side setback: one side 8 ft; total both sides 20 ft (On slopes of 16% or more but under 26%: 20 ft on one side and 45 ft total.)
  • Minimum lot size: 10,000 sf
  • Maximum density: 4 du/gross acre

R1-10 is a zoning district in Milpitas. Every value below was read from the Milpitas Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in R1-10

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
30 ft
§ B.4.030 · code text
Table row “Primary Building Height, max.”, column “R1-10”: 30 ft
Minimum front setback
25 ft
Applies: 40 ft where the property slope is 16% or more.
§ B.4.030 · code text
Table row “Front”, column “R1-10”: Min.: 25 4
Minimum side setback
one side 8 ft; total both sides 20 ft
Applies: On slopes of 16% or more but under 26%: 20 ft on one side and 45 ft total.
§ B.4.030 · code text
Table row “Interior side”, column “R1-10”: One side, min.: 8 Total both sides, min.: 20 8
Minimum lot size
10,000 sf
§ B.4.030 · code text
Table row “Lot Area, min”, column “R1-10”: 10,000 sf
Maximum density
4 du/gross acre
§ B.4.030 · code text
Table row “Density (du/gross acre) 2”, column “R1-10”: Min.: 3 Max.: 4

When a different number applies

The code sets other values for particular lots, buildings or locations in R1-10:

  • Minimum side setback: 40 ft — property slope equal to or greater than 26% § B.4.030
  • Minimum rear setback: 30 ft — 1 story; 40 ft where the property slope is 16% or more. § B.4.030
  • Minimum rear setback: 35 ft — 2 or more stories; 40 ft where the property slope is 16% or more. § B.4.030

Not on this page

We did not find a general stories, rear setback, lot coverage, FAR limit for R1-10 in the zoning tables we read. The code may still set one elsewhere — check the Milpitas Municipal Code.

Other Milpitas zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Milpitas's R1-10 zone?

30 ft — Milpitas Municipal Code § B.4.030.

What is the minimum front setback in Milpitas's R1-10 zone?

25 ft (40 ft where the property slope is 16% or more) — Milpitas Municipal Code § B.4.030.

What is the minimum side setback in Milpitas's R1-10 zone?

one side 8 ft; total both sides 20 ft (on slopes of 16% or more but under 26%: 20 ft on one side and 45 ft total) — Milpitas Municipal Code § B.4.030.

What is the minimum lot size in Milpitas's R1-10 zone?

10,000 sf — Milpitas Municipal Code § B.4.030.

What is the maximum density in Milpitas's R1-10 zone?

4 du/gross acre — Milpitas Municipal Code § B.4.030.

General information, not legal advice.

Ask about a Milpitas property in R1-10

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Milpitas