In Newark's RH zone, generally buildings can be up to 100 ft tall, the front setback is 15 ft and the minimum lot size is 6,000 sq ft, with the conditions listed below (Newark code, read October 2026).

Key points

  • Maximum building height: 100 ft (Heights over 35 ft need a minor use permit, except in the Old Town Specific Plan area.)
  • Minimum front setback: 15 ft
  • Minimum side setback: 5 ft
  • Minimum rear setback: 10 ft
  • Minimum lot size: 6,000 sq ft
  • Maximum lot coverage: 55%
  • Maximum density: 60 units/net acre

RH is a zoning district in Newark. Every value below was read from the Newark Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in RH

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
100 ft
Applies: Heights over 35 ft need a minor use permit, except in the Old Town Specific Plan area.
§ 17.07.030 · code text
Table row “Maximum Height (ft)”, column “RH”: 100, 35 within 20 ft of an RS or RL District(C)
Minimum front setback
15 ft
§ 17.07.030 · code text
Table row “Front”, column “RH”: 15
Minimum side setback
5 ft
§ 17.07.030 · code text
Table row “Interior Side”, column “RH”: 5(B)
Minimum rear setback
10 ft
§ 17.07.030 · code text
Table row “Rear”, column “RH”: 10
Minimum lot size
6,000 sq ft
§ 17.07.030 · code text
Table row “Minimum Lot Size (sq ft)”, column “RH”: 6,000
Maximum lot coverage
55%
§ 17.07.030 · code text
Table row “Maximum Lot Coverage (% of lot)”, column “RH”: 55
Maximum density
60 units/net acre
§ 17.07.030 · code text
Table row “Maximum”, column “RH”: 60

Uses in RH

Uses the code's use tables allow in RH, or allow with a permit. Each links to its page with the code section.

When a different number applies

The code sets other values for particular lots, buildings or locations in RH:

  • Maximum building height: 35 ft — within 20 ft of an RS or RL District § 17.07.030

Not on this page

We did not find a general stories, FAR limit for RH in the zoning tables we read. The code may still set one elsewhere — check the Newark Municipal Code.

Other Newark zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Newark's RH zone?

100 ft (heights over 35 ft need a minor use permit, except in the Old Town Specific Plan area) — Newark Municipal Code § 17.07.030.

What is the minimum front setback in Newark's RH zone?

15 ft — Newark Municipal Code § 17.07.030.

What is the minimum side setback in Newark's RH zone?

5 ft — Newark Municipal Code § 17.07.030.

What is the minimum rear setback in Newark's RH zone?

10 ft — Newark Municipal Code § 17.07.030.

What is the minimum lot size in Newark's RH zone?

6,000 sq ft — Newark Municipal Code § 17.07.030.

General information, not legal advice.