Skip to content

Norco · Zoning · R-1

Norco R-1 zoning: height, setbacks and lot size

In Norco's R-1 zone, generally buildings can be up to 35 ft tall and the minimum lot size is 10,000 sq ft, with the conditions listed below (Norco code, read October 2026).

Key points

  • Maximum building height: 35 ft (Maximum is two and one-half stories or 35 feet, whichever is less)
  • Minimum side setback: 5 ft (Interior side yard for lots of 10,000 square feet or less)
  • Minimum rear setback: 15 ft
  • Minimum lot size: 10,000 sq ft (Lots hereafter created; the zone suffix sets the minimum, never less than 10,000 sq ft.)
  • Maximum lot coverage: 50%

R-1 (Residential Single-Family) is a zoning district in Norco. Every value below was read from the Norco Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in R-1

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
Applies: Maximum is two and one-half stories or 35 feet, whichever is less
§ 18.15.18 · code text
The maximum height of any main building shall be two and one-half stories or 35 feet, whichever is less.
Minimum side setback
5 ft
Applies: Interior side yard for lots of 10,000 square feet or less
§ 18.15.12 · code text
(i) All lots of 10,000 square feet or less; a minimum of five feet.
Minimum rear setback
15 ft
§ 18.15.12 · code text
(3) Rear Yard: Minimum of 15 feet.
Minimum lot size
10,000 sq ft
Applies: Lots hereafter created; the zone suffix sets the minimum, never less than 10,000 sq ft.
§ 18.15.10 · code text
All lots in this zone shall contain a minimum lot area as prescribed by the suffix applicable thereto; provided, that there shall be at least 10,000 square feet in all lots hereafter created, and no lot in this zone shall be reduced below this minimum.
Maximum lot coverage
50%
§ 18.15.20 · code text
The maximum lot coverage of all structures shall be not more than 50 percent of the total lot area.

When a different number applies

The code sets other values for particular lots, buildings or locations in R-1:

  • Minimum side setback: One side at least 5 ft, other at least 12 ft; the two total at least 20 ft — Interior side yards on lots over 10,000 sq ft. § 18.15.12
  • Minimum side setback: 20% of lot width, max 15 ft — Corner side yard on the street side § 18.15.12

Not on this page

We did not find a general stories, front setback, FAR, density limit for R-1 in the zoning tables we read. The code may still set one elsewhere — check the Norco Municipal Code.

Other Norco zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Norco's R-1 zone?

35 ft (maximum is two and one-half stories or 35 feet, whichever is less) — Norco Municipal Code § 18.15.18.

What is the minimum side setback in Norco's R-1 zone?

5 ft (interior side yard for lots of 10,000 square feet or less) — Norco Municipal Code § 18.15.12.

What is the minimum rear setback in Norco's R-1 zone?

15 ft — Norco Municipal Code § 18.15.12.

What is the minimum lot size in Norco's R-1 zone?

10,000 sq ft (lots hereafter created; the zone suffix sets the minimum, never less than 10,000 sq ft) — Norco Municipal Code § 18.15.10.

What is the maximum lot coverage in Norco's R-1 zone?

50% — Norco Municipal Code § 18.15.20.

General information, not legal advice.

Ask about a Norco property in R-1

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question