Skip to content

Placentia · Zoning · R-G

Placentia R-G zoning: height, setbacks and lot size

In Placentia's R-G zone, generally buildings can be up to 35 ft tall, the front setback is 20 ft and the minimum lot size is 8,000 sq ft, with the conditions listed below (Placentia code, read October 2026).

Key points

  • Maximum building height: 35 ft (30 ft when adjacent to R-A or R-1 property; 35 ft allowed with 2 ft extra setback per additional foot of height)
  • Minimum front setback: 20 ft
  • Minimum side setback: 10 ft (Interior side lot line; buildings with living units and most accessory structures.)
  • Minimum lot size: 8,000 sq ft (Interior lot)
  • Maximum lot coverage: 60% (Counts buildings, parking areas, driveways and covered patios.)

R-G (Medium Density Multiple-Family District) is a zoning district in Placentia. Every value below was read from the Placentia Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in R-G

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
Applies: 30 ft when adjacent to R-A or R-1 property; 35 ft allowed with 2 ft extra setback per additional foot of height
§ 23.18.040 · code text
Maximum allowable height in the “R-G” district shall be thirty-five (35) feet, except when located adjacent to properties zoned R-A or R-1, where the maximum height shall be thirty (30) feet, however a thirty-five (35) foot maximum height shall be permitted when two (2) feet of additional setback is provided for every one (1) foot of additional height.
Minimum front setback
20 ft
§ 23.18.070 · code text
Minimum front yard in the “R” district shall be twenty (20) feet, fully landscaped with no encroachment except for driveways, from any street right-of-way.
Minimum side setback
10 ft
Applies: Interior side lot line; buildings with living units and most accessory structures.
§ 23.18.080 · code text
Buildings containing living units and accessory structures not specified in subsection (B) below, ten (10) feet,
Minimum lot size
8,000 sq ft
Applies: Interior lot
§ 23.18.050 · code text
Interior lot, eight thousand (8,000) square feet;
Maximum lot coverage
60%
Applies: Counts buildings, parking areas, driveways and covered patios.
§ 23.18.060 · code text
Maximum allowable lot coverage in the “R-G” district shall be as follows: Not more than sixty (60) percent of the total lot area shall be devoted to main and accessory building area, parking area, driveways and covered patios.

Uses in R-G

Uses the code's use tables allow in R-G, or allow with a permit. Each links to its page with the code section.

When a different number applies

The code sets other values for particular lots, buildings or locations in R-G:

  • Maximum building height: 30 ft — Adjacent to R-A or R-1 zoned property. 35 ft allowed with 2 ft of extra setback per extra foot of height. § 23.18.040
  • Minimum side setback: 20 ft — Street side of corner lot § 23.18.080
  • Minimum side setback: None required — Garages and carports on an interior side lot line, unless required by the planning commission or city council under Chapter 23.75 § 23.18.080
  • Minimum rear setback: 10 ft — Buildings containing dwelling units and accessory buildings not specified in subsection (2) § 23.18.090
  • Minimum rear setback: None required — Garages and carports, unless required by the planning commission or city council under Chapter 23.75 § 23.18.090
  • Minimum lot size: 9,000 sq ft — Corner lot § 23.18.050
  • Minimum lot size: 40,000 sq ft — Private schools and churches; net area § 23.18.050

Not on this page

We did not find a general stories, rear setback, FAR, density limit for R-G in the zoning tables we read. The code may still set one elsewhere — check the Placentia Municipal Code.

Other Placentia zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Placentia's R-G zone?

35 ft (30 ft when adjacent to R-A or R-1 property; 35 ft allowed with 2 ft extra setback per additional foot of height) — Placentia Municipal Code § 23.18.040.

What is the minimum front setback in Placentia's R-G zone?

20 ft — Placentia Municipal Code § 23.18.070.

What is the minimum side setback in Placentia's R-G zone?

10 ft (interior side lot line; buildings with living units and most accessory structures) — Placentia Municipal Code § 23.18.080.

What is the minimum lot size in Placentia's R-G zone?

8,000 sq ft (interior lot) — Placentia Municipal Code § 23.18.050.

What is the maximum lot coverage in Placentia's R-G zone?

60% (counts buildings, parking areas, driveways and covered patios) — Placentia Municipal Code § 23.18.060.

General information, not legal advice.

Ask about a Placentia property in R-G

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Placentia