In Redding's RE-2 zone, buildings can be up to 35 ft tall and the front setback is 25 ft (Redding code, read October 2026).

Key points

  • Maximum building height: 35 ft
  • Minimum front setback: 25 ft
  • Minimum side setback: 30 ft aggregate; no side less than 10 ft
  • Minimum rear setback: 15 ft
  • Maximum lot coverage: 40%
  • Maximum density: 2 units per acre

RE-2 (Residential Estate) is a zoning district in Redding. Every value below was read from the Redding Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in RE-2

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
§ 18.31.030 · code text
Table row “Maximum Height (feet)”, column “"RE-1" "RE-2"”: 35
Minimum front setback
25 ft
§ 18.31.030 · code text
Table row “Front”, column “"RE-1" "RE-2"”: 25
Minimum side setback
30 ft aggregate; no side less than 10 ft
§ 18.31.030 · code text
Table row “Side”, column “"RE-1" "RE-2"”: Aggregate 30'; no side less than 10'
Minimum rear setback
15 ft
§ 18.31.030 · code text
Table row “Rear”, column “"RE-1" "RE-2"”: 15
Maximum lot coverage
40%
§ 18.31.030 · code text
Table row “Maximum Lot Coverage”, column “"RE-1" "RE-2"”: 40%
Maximum density
2 units per acre
§ 18.31.030 · code text
Table row “RE-2”, column “Maximum Density: Units per gross developable acre”: 2

Not on this page

We did not find a general stories, lot size, FAR limit for RE-2 in the zoning tables we read. The code may still set one elsewhere — check the Redding Municipal Code.

Other Redding zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Redding's RE-2 zone?

35 ft — Redding Municipal Code § 18.31.030.

What is the minimum front setback in Redding's RE-2 zone?

25 ft — Redding Municipal Code § 18.31.030.

What is the minimum side setback in Redding's RE-2 zone?

30 ft aggregate; no side less than 10 ft — Redding Municipal Code § 18.31.030.

What is the minimum rear setback in Redding's RE-2 zone?

15 ft — Redding Municipal Code § 18.31.030.

What is the maximum lot coverage in Redding's RE-2 zone?

40% — Redding Municipal Code § 18.31.030.

General information, not legal advice.

Ask about a Redding property in RE-2

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Redding