Redondo Beach · Zoning · I-2A
Redondo Beach I-2A zoning: height, setbacks and lot size
In Redondo Beach's I-2A zone, generally buildings can be up to 30 ft (2 stories) tall and the front setback is 15 ft, with the conditions listed below (Redondo Beach code, read October 2026).
Key points
- Maximum building height: 30 ft (subject to an exception the code lists right after this sentence (coastal zone only (Chapter 5 coastal zoning)))
- Maximum number of stories: 2 stories (Coastal zone only (Chapter 5 coastal zoning))
- Minimum front setback: 15 ft (Coastal zone only (Chapter 5 coastal zoning))
- Maximum floor area ratio (FAR): 1.0 (Coastal zone only (Chapter 5 coastal zoning))
I-2A (industrial zone) is a zoning district in Redondo Beach. Every value below was read from the Redondo Beach Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.
Development standards in I-2A
The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.
| Maximum building height | 30 ft Applies: subject to an exception the code lists right after this sentence (coastal zone only (Chapter 5 coastal zoning)) § 10-5.1016 · code textNo building or structure shall exceed a height of 30 feet, except as follows (See definition of "building height" in Section 10-5.402): |
|---|---|
| Maximum number of stories | 2 stories Applies: Coastal zone only (Chapter 5 coastal zoning) § 10-5.1016 · code textNo building shall exceed two stories. (See definition of "story" in Section 10-5.402.) |
| Minimum front setback | 15 ft Applies: Coastal zone only (Chapter 5 coastal zoning) § 10-5.1016 · code textThere shall be a minimum front setback of 15 feet the full width of the lot. |
| Maximum floor area ratio (FAR) | 1.0 Applies: Coastal zone only (Chapter 5 coastal zoning) § 10-5.1016 · code textThe floor area ratio (FAR) of all buildings on a lot shall not exceed 1.0 (see definition of floor area ratio in Section 10-5.402). |
Uses in I-2A
Uses the code's use tables allow in I-2A, or allow with a permit. Each links to its page with the code section.
- Child care center — Needs a conditional use permit
When a different number applies
The code sets other values for particular lots, buildings or locations in I-2A:
- Minimum side setback: 15 ft — street side of a corner or reverse corner lot (coastal zone only (Chapter 5 coastal zoning)) § 10-5.1016
Not on this page
We did not find a general side setback, rear setback, lot size, lot coverage, density limit for I-2A in the zoning tables we read. The code may still set one elsewhere — check the Redondo Beach Municipal Code.
Other Redondo Beach zoning districts
Who this affects
Frequently asked questions
What is the maximum building height in Redondo Beach's I-2A zone?
30 ft (subject to an exception the code lists right after this sentence (coastal zone only (Chapter 5 coastal zoning))) — Redondo Beach Municipal Code § 10-5.1016.
What is the maximum number of stories in Redondo Beach's I-2A zone?
2 stories (coastal zone only (Chapter 5 coastal zoning)) — Redondo Beach Municipal Code § 10-5.1016.
What is the minimum front setback in Redondo Beach's I-2A zone?
15 ft (coastal zone only (Chapter 5 coastal zoning)) — Redondo Beach Municipal Code § 10-5.1016.
What is the maximum floor area ratio (far) in Redondo Beach's I-2A zone?
1.0 (coastal zone only (Chapter 5 coastal zoning)) — Redondo Beach Municipal Code § 10-5.1016.
General information, not legal advice.
Ask about a Redondo Beach property in I-2A
Ask GoCodebook what you can build at a specific address and get an answer that cites the section.
Ask your question