Skip to content

Rocklin · Zoning · OA

Rocklin OA zoning: height, setbacks and lot size

In Rocklin's OA zone, buildings can be up to 35 ft tall, the front setback is 20 ft and the minimum lot size is 1 net acre (Rocklin code, read October 2026).

Key points

  • Maximum building height: 35 ft
  • Minimum front setback: 20 ft
  • Minimum side setback: 10 ft
  • Minimum rear setback: 10 ft
  • Minimum lot size: 1 net acre
  • Maximum lot coverage: 50%

OA (OA Zone) is a zoning district in Rocklin. Every value below was read from the Rocklin Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in OA

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
§ 17.58.020 · code text
The maximum height for buildings and structures in the OA zone shall be thirty-five feet.
Minimum front setback
20 ft
§ 17.58.060 · code text
There shall be a front setback of not less than twenty feet.
Minimum side setback
10 ft
§ 17.58.060 · code text
There shall be an interior side setback of not less than ten feet.
Minimum rear setback
10 ft
§ 17.58.060 · code text
There shall be a rear setback of not less than ten feet.
Minimum lot size
1 net acre
§ 17.58.030 · code text
The minimum area for each lot in the OA zone shall be one net acre.
Maximum lot coverage
50%
§ 17.58.040 · code text
The maximum lot coverage by all structures and buildings in the OA zone shall not exceed fifty percent of the lot area.

Not on this page

We did not find a general stories, FAR, density limit for OA in the zoning tables we read. The code may still set one elsewhere — check the Rocklin Municipal Code.

Other Rocklin zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Rocklin's OA zone?

35 ft — Rocklin Municipal Code § 17.58.020.

What is the minimum front setback in Rocklin's OA zone?

20 ft — Rocklin Municipal Code § 17.58.060.

What is the minimum side setback in Rocklin's OA zone?

10 ft — Rocklin Municipal Code § 17.58.060.

What is the minimum rear setback in Rocklin's OA zone?

10 ft — Rocklin Municipal Code § 17.58.060.

What is the minimum lot size in Rocklin's OA zone?

1 net acre — Rocklin Municipal Code § 17.58.030.

General information, not legal advice.

Ask about a Rocklin property in OA

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question