Skip to content

San Jacinto · Zoning · RM

San Jacinto RM zoning: height, setbacks and lot size

In San Jacinto's RM zone, generally buildings can be up to 35 ft tall, the front setback is 15 ft and the minimum lot size is 4,000 sq. ft., with the conditions listed below (San Jacinto code, read October 2026).

Key points

  • Maximum building height: 35 ft (Primary Structure)
  • Minimum front setback: 15 ft (House)
  • Minimum side setback: 5 ft
  • Minimum rear setback: 10 ft
  • Minimum lot size: 4,000 sq. ft.
  • Maximum density: 14.0 units per gross acre

RM is a zoning district in San Jacinto. Every value below was read from the San Jacinto Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in RM

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
Applies: Primary Structure
§ 17.215.030 · code text
Table row “Primary Structure”, column “RM”: 35 ft.
Minimum front setback
15 ft
Applies: House
§ 17.215.030 · code text
Table row “Front”, column “RM”: 15 ft. -House 20 ft. - Garage
Minimum side setback
5 ft
§ 17.215.030 · code text
Table row “Interior Side”, column “RM”: 5 ft.
Minimum rear setback
10 ft
§ 17.215.030 · code text
Table row “Rear”, column “RM”: 10 ft.
Minimum lot size
4,000 sq. ft.
§ 17.215.030 · code text
Table row “Parcel Area”, column “RM”: 4,000 sq. ft.
Maximum density
14.0 units per gross acre
§ 17.215.030 · code text
Table row “Maximum”, column “RM”: 14.0

Uses in RM

Uses the code's use tables allow in RM, or allow with a permit. Each links to its page with the code section.

When a different number applies

The code sets other values for particular lots, buildings or locations in RM:

  • Minimum front setback: 20 ft — Garage § 17.215.030
  • Minimum front setback: 20 ft — Multi-family projects, single-story building; taller buildings need more (see below) § 17.420.050
  • Minimum front setback: 25 ft — Multi-family projects, two-story building or taller § 17.420.050
  • Minimum side setback: 10 ft — Multi-family projects, single-story building; taller buildings need more (see below) § 17.420.050
  • Minimum side setback: 15 ft — Multi-family projects, two-story building § 17.420.050
  • Minimum side setback: 25 ft — Multi-family projects, three-story building or taller § 17.420.050
  • Minimum rear setback: 15 ft — Multi-family projects, two-story building § 17.420.050
  • Minimum rear setback: 25 ft — Multi-family projects, three-story building or taller § 17.420.050

Not on this page

We did not find a general stories, lot coverage, FAR limit for RM in the zoning tables we read. The code may still set one elsewhere — check the San Jacinto Municipal Code.

Other San Jacinto zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in San Jacinto's RM zone?

35 ft (primary Structure) — San Jacinto Municipal Code § 17.215.030.

What is the minimum front setback in San Jacinto's RM zone?

15 ft (house) — San Jacinto Municipal Code § 17.215.030.

What is the minimum side setback in San Jacinto's RM zone?

5 ft — San Jacinto Municipal Code § 17.215.030.

What is the minimum rear setback in San Jacinto's RM zone?

10 ft — San Jacinto Municipal Code § 17.215.030.

What is the minimum lot size in San Jacinto's RM zone?

4,000 sq. ft. — San Jacinto Municipal Code § 17.215.030.

General information, not legal advice.

Ask about a San Jacinto property in RM

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on San Jacinto