Skip to content

Santa Barbara County · Building on your lot

Outdoor lighting in Santa Barbara County

Santa Barbara County's own rules on outdoor lighting, with the code text for every value.

Each rule below links to the section of the Santa Barbara County Municipal Code it was read from, with the code text one click away (checked October 2026). General information, not legal advice.

What Santa Barbara County's code says

Santa Barbara County code What Santa Barbara County's code adds
Light at the property line
  • Light at property lines may be at most 0.1 foot-candles.
    Applies: New or replaced outdoor lighting; higher limits apply between multi-family, commercial and industrial zones.
    § 35.30.120 · code text
    The light level at property lines shall not exceed 0.1 foot-candles, except as provided below.
  • Light at the shared property line may be at most 0.2 foot-candles.
    Applies: Multi-family zoned property next to a multi-family, commercial or industrial zone.
    § 35.30.120 · code text
    Where a property is located within a Multi-family Zone and the neighboring property is located within a Multi-family, Commercial, or Industrial Zone, the maximum lighting level at the shared property line shall be 0.2 foot-candles.
Shielding
  • Outdoor fixtures must be fully shielded or full cut off.
    § 35.30.120 · code text
    All outdoor light fixtures shall be fully shielded or full cut off, except as provided below.
  • Shielding is not required.
    Applies: Decorative string lights.
    § 35.30.120 · code text
    Decorative string lights are not required to be shielded.
  • Shielding is not required if no light goes above the edge of the overhang.
    Applies: Lights at building entrances under an overhang or building element.
    § 35.30.120 · code text
    Lights at building entrances located under an overhang or building element are not required to be shielded provided that none of the light emitted by the fixture projects above the horizontal of the edge of the overhang or building element.
  • Partly shielded fixtures up to 850 lumens are allowed if the bulb is hidden by frosted glass or similar.
    § 35.30.120 · code text
    Partially shielded light fixtures may be allowed provided the light source is obscured by translucent glass or other means, the light fixture does not exceed 850 lumens, and the lighting complies with all other provisions of this Section.
  • Outdoor lights must be hooded, with no open beam aimed at homes or sensitive habitat areas.
    § 35-139 · code text
    All exterior lighting shall be hooded and no unobstructed beam of exterior lighting shall be directed toward any area zoned or developed residential, or toward any environmentally sensitive habitat area.

Who this affects

HomeownersContractorsDesigners

Frequently asked questions

What are the outdoor lighting rules for homes in Santa Barbara County?

Santa Barbara County's code: Outdoor fixtures must be fully shielded or full cut off. (§ 35.30.120); Light at property lines may be at most 0.1 foot-candles. (New or replaced outdoor lighting; higher limits apply between multi-family, commercial and industrial zones.) (§ 35.30.120).

General information, not legal advice.