In Santee's R-30 zone, buildings can be up to 55 ft (5 stories) tall and the front setback is 10 ft (Santee code, read October 2026).

Key points

  • Maximum building height: 55 ft
  • Maximum number of stories: 5 stories
  • Minimum front setback: 10 ft
  • Minimum side setback: 10 ft (interior side yard; 15 ft when abutting a single-family zone and buildings exceed 35 feet)
  • Minimum rear setback: 10 ft
  • Maximum lot coverage: 75%
  • Maximum density: 30 to 36 units per gross acre (the code sets a range: at least 30, at most 36)

R-30 is a zoning district in Santee. Every value below was read from the Santee Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in R-30

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
55 ft
§ 13.10.040 · code text
Table row “7. Maximum Height (in feet)”, column “R-30”: 55 (five stories)
Maximum number of stories
5 stories
§ 13.10.040 · code text
Table row “7. Maximum Height (in feet)”, column “R-30”: 55 (five stories)
Minimum front setback
10 ft
§ 13.10.040 · code text
Table row “Front 5, 6”, column “R-30”: 10
Minimum side setback
10 ft
Applies: interior side yard; 15 ft when abutting a single-family zone and buildings exceed 35 feet
§ 13.10.040 · code text
Table row “Interior side yard”, column “R-30”: 10 or 15 2
Minimum rear setback
10 ft
§ 13.10.040 · code text
Table row “Rear”, column “R-30”: 10 or 15 2
Maximum lot coverage
75%
§ 13.10.040 · code text
Table row “5. Maximum Lot Coverage”, column “R-30”: 75%
Maximum density
30 to 36 units per gross acre
Applies: the code sets a range: at least 30, at most 36
§ 13.10.040 · code text
Table row “2. Density Ranges (in du/gross acre)”, column “R-30”: 30-36

Uses in R-30

Uses the code's use tables allow in R-30, or allow with a permit. Each links to its page with the code section.

When a different number applies

The code sets other values for particular lots, buildings or locations in R-30:

  • Minimum side setback: 15 ft — when abutting a Single-family Residential Zone and buildings exceed 35 feet (two stories) § 13.10.040
  • Minimum rear setback: 15 ft — when abutting a Single-family Residential Zone and buildings exceed 35 feet (two stories) § 13.10.040

Not on this page

We did not find a general lot size, FAR limit for R-30 in the zoning tables we read. The code may still set one elsewhere — check the Santee Municipal Code.

Other Santee zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Santee's R-30 zone?

55 ft — Santee Municipal Code § 13.10.040.

What is the maximum number of stories in Santee's R-30 zone?

5 stories — Santee Municipal Code § 13.10.040.

What is the minimum front setback in Santee's R-30 zone?

10 ft — Santee Municipal Code § 13.10.040.

What is the minimum side setback in Santee's R-30 zone?

10 ft (interior side yard; 15 ft when abutting a single-family zone and buildings exceed 35 feet) — Santee Municipal Code § 13.10.040.

What is the minimum rear setback in Santee's R-30 zone?

10 ft — Santee Municipal Code § 13.10.040.

General information, not legal advice.

Ask about a Santee property in R-30

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.