Seaside · Zoning · CVSR
Seaside CVSR zoning: height, setbacks and lot size
In Seaside's CVSR zone, generally buildings can be up to 24 ft tall and the minimum lot size is 0.5 acres, with the conditions listed below (Seaside code, read October 2026).
Key points
- Maximum building height: 24 ft (lower heights may be required to protect public views; see the special standards for each subarea)
- Minimum lot size: 0.5 acres
- Maximum lot coverage: 50%
- Maximum floor area ratio (FAR): 0.5
CVSR is a zoning district in Seaside. Every value below was read from the Seaside Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.
Development standards in CVSR
The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.
| Maximum building height | 24 ft Applies: lower heights may be required to protect public views; see the special standards for each subarea § 18.02.060 · code textTable row “Maximum structure height (except where lower heights are necessary to protect public views) (4, 7)”, column “CVSR”: 24 ft. |
|---|---|
| Minimum lot size | 0.5 acres § 18.02.060 · code textTable row “Minium lot area”, column “CVSR”: 0.5 acres |
| Maximum lot coverage | 50% § 18.02.060 · code textTable row “Maximum building site coverage”, column “CVSR”: 50% |
| Maximum floor area ratio (FAR) | 0.5 § 18.02.060 · code textTable row “Floor area ratio (FAR)”, column “CVSR”: 0.5:1 |
Not on this page
We did not find a general stories, front setback, side setback, rear setback, density limit for CVSR in the zoning tables we read. The code may still set one elsewhere — check the Seaside Municipal Code.
Other Seaside zoning districts
Who this affects
Frequently asked questions
What is the maximum building height in Seaside's CVSR zone?
24 ft (lower heights may be required to protect public views; see the special standards for each subarea) — Seaside Municipal Code § 18.02.060.
What is the minimum lot size in Seaside's CVSR zone?
0.5 acres — Seaside Municipal Code § 18.02.060.
What is the maximum lot coverage in Seaside's CVSR zone?
50% — Seaside Municipal Code § 18.02.060.
What is the maximum floor area ratio (far) in Seaside's CVSR zone?
0.5 — Seaside Municipal Code § 18.02.060.
General information, not legal advice.
Ask about a Seaside property in CVSR
Ask GoCodebook what you can build at a specific address and get an answer that cites the section.
Ask your question