In Stockton's PF zone, buildings can be up to 75 ft tall and the front setback is 10 ft (Stockton code, read October 2026).

Key points

  • Maximum building height: 75 ft
  • Minimum front setback: 10 ft
  • Minimum side setback: 0 ft (not adjacent to a residential zone)
  • Minimum rear setback: 0 ft (not adjacent to a residential zone)
  • Maximum floor area ratio (FAR): 0.5 (Other Areas)

PF is a zoning district in Stockton. Every value below was read from the Stockton Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in PF

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
75 ft
§ 16.24.160 · code text
Table row “Maximum Height (ft)”, column “PF”: 75
Minimum front setback
10 ft
§ 16.24.160 · code text
Table row “Front”, column “PF”: 10
Minimum side setback
0 ft
Applies: not adjacent to a residential zone
§ 16.24.160 · code text
Table row “Interior Side”, column “PF”: 0, 10 adjacent to Residential Zone
Minimum rear setback
0 ft
Applies: not adjacent to a residential zone
§ 16.24.160 · code text
Table row “Rear”, column “PF”: 0, 10 adjacent to Residential Zone
Maximum floor area ratio (FAR)
0.5
Applies: Other Areas
§ 16.24.160 · code text
Table row “Maximum Floor Area Ratio (FAR)”, column “PF”: Downtown Core: 5.0 Other Areas: 0.5

Uses in PF

Uses the code's use tables allow in PF, or allow with a permit. Each links to its page with the code section.

When a different number applies

The code sets other values for particular lots, buildings or locations in PF:

  • Minimum side setback: 10 ft — Adjacent to Residential Zone § 16.24.160
  • Minimum rear setback: 10 ft — Adjacent to Residential Zone § 16.24.160
  • Maximum floor area ratio (FAR): 5.0 — Downtown Core § 16.24.160

Not on this page

We did not find a general stories, lot size, lot coverage, density limit for PF in the zoning tables we read. The code may still set one elsewhere — check the Stockton Municipal Code.

Other Stockton zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Stockton's PF zone?

75 ft — Stockton Municipal Code § 16.24.160.

What is the minimum front setback in Stockton's PF zone?

10 ft — Stockton Municipal Code § 16.24.160.

What is the minimum side setback in Stockton's PF zone?

0 ft (not adjacent to a residential zone) — Stockton Municipal Code § 16.24.160.

What is the minimum rear setback in Stockton's PF zone?

0 ft (not adjacent to a residential zone) — Stockton Municipal Code § 16.24.160.

What is the maximum floor area ratio (far) in Stockton's PF zone?

0.5 (other Areas) — Stockton Municipal Code § 16.24.160.