In Sunnyvale's R-0 zone, buildings can be up to 30 ft (2 stories) tall, the front setback is 15 ft and the minimum lot size is 6,000 sq ft (Sunnyvale code, read October 2026).

Key points

  • Maximum building height: 30 ft
  • Maximum number of stories: 2 stories
  • Minimum front setback: 15 ft
  • Minimum side setback: 20% of lot width, but not less than 10 ft. (total of both side yards added together)
  • Minimum rear setback: 20 ft
  • Minimum lot size: 6,000 sq ft
  • Maximum lot coverage: 50%
  • Maximum floor area ratio (FAR): 60%
  • Maximum density: 1 unit per 6,000 sq ft

R-0 is a zoning district in Sunnyvale. Every value below was read from the Sunnyvale Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in R-0

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
30 ft
§ 19.32.020 · code text
Table row “R-0”, column “Building Height (ft.)”: 30
Maximum number of stories
2 stories
§ 19.32.020 · code text
Table row “R-0”, column “Building Stories”: 2
Minimum front setback
15 ft
§ 19.34.030 · code text
Table row “R-0”, column “Front Yard Minimum 1, 2”: 15
Minimum side setback
20% of lot width, but not less than 10 ft.
Applies: total of both side yards added together
§ 19.34.030 · code text
Table row “R-0”, column “Side Yards Total 1, 3, 4”: 20% of lot width but not less than 10 ft. 8
Minimum rear setback
20 ft
§ 19.34.030 · code text
Table row “R-0”, column “Rear Yard 1, 6”: 20
Minimum lot size
6,000 sq ft
§ 19.30.020 · code text
Table row “R-0”, column “Lot Area Minimum (Square feet)”: 6,000
Maximum lot coverage
50%
§ 19.32.020 · code text
Table row “R-0”, column “Lot Coverage”: 50%
Maximum floor area ratio (FAR)
60%
§ 19.32.020 · code text
Table row “R-0”, column “Floor Area Ratio (FAR)”: 60%
Maximum density
1 unit per 6,000 sq ft
§ 19.30.020 · code text
Table row “R-0”, column “Lot Area Per Dwelling Unit (Square Feet)”: 6,000

When a different number applies

The code sets other values for particular lots, buildings or locations in R-0:

  • Minimum front setback: 25 ft — second story of any two-story residential development § 19.34.045
  • Minimum side setback: 4 ft — one side § 19.34.030

Other Sunnyvale zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Sunnyvale's R-0 zone?

30 ft — Sunnyvale Municipal Code § 19.32.020.

What is the maximum number of stories in Sunnyvale's R-0 zone?

2 stories — Sunnyvale Municipal Code § 19.32.020.

What is the minimum front setback in Sunnyvale's R-0 zone?

15 ft — Sunnyvale Municipal Code § 19.34.030.

What is the minimum side setback in Sunnyvale's R-0 zone?

20% of lot width, but not less than 10 ft. (total of both side yards added together) — Sunnyvale Municipal Code § 19.34.030.

What is the minimum rear setback in Sunnyvale's R-0 zone?

20 ft — Sunnyvale Municipal Code § 19.34.030.

General information, not legal advice.

Ask about a Sunnyvale property in R-0

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question