Trinidad · Zoning · PR
Trinidad PR zoning: height, setbacks and lot size
In Trinidad's PR zone, generally buildings can be up to 25 ft tall and the front setback is 20 ft, with the conditions listed below (Trinidad code, read October 2026).
Key points
- Maximum building height: 25 ft (greater height may be permitted with a use permit)
- Minimum front setback: 20 ft
- Minimum side setback: 5 ft (none when adjacent to PR or C zones)
- Minimum rear setback: 5 ft (none when adjacent to PR or C zones)
PR is a zoning district in Trinidad. Every value below was read from the Trinidad Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.
Development standards in PR
The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.
| Maximum building height | 25 ft Applies: greater height may be permitted with a use permit § 17.48.050 · code textMaximum building height in the PR zone is 25 feet, except that greater height may be permitted subject to obtaining a use permit. |
|---|---|
| Minimum front setback | 20 ft § 17.48.040 · code textMinimum yards in the PR zone are front, 20 feet; rear and side yards, five feet, except none when adjacent to PR or C zones. |
| Minimum side setback | 5 ft Applies: none when adjacent to PR or C zones § 17.48.040 · code textMinimum yards in the PR zone are front, 20 feet; rear and side yards, five feet, except none when adjacent to PR or C zones. |
| Minimum rear setback | 5 ft Applies: none when adjacent to PR or C zones § 17.48.040 · code textMinimum yards in the PR zone are front, 20 feet; rear and side yards, five feet, except none when adjacent to PR or C zones. |
When a different number applies
The code sets other values for particular lots, buildings or locations in PR:
- Minimum side setback: None required — Adjacent to PR or C zones § 17.48.040
- Minimum rear setback: None required — Adjacent to PR or C zones § 17.48.040
Not on this page
We did not find a general stories, lot size, lot coverage, FAR, density limit for PR in the zoning tables we read. The code may still set one elsewhere — check the Trinidad Municipal Code.
Other Trinidad zoning districts
Who this affects
Frequently asked questions
What is the maximum building height in Trinidad's PR zone?
25 ft (greater height may be permitted with a use permit) — Trinidad Municipal Code § 17.48.050.
What is the minimum front setback in Trinidad's PR zone?
20 ft — Trinidad Municipal Code § 17.48.040.
What is the minimum side setback in Trinidad's PR zone?
5 ft (none when adjacent to PR or C zones) — Trinidad Municipal Code § 17.48.040.
What is the minimum rear setback in Trinidad's PR zone?
5 ft (none when adjacent to PR or C zones) — Trinidad Municipal Code § 17.48.040.