Skip to content

West Sacramento · Zoning · RE

West Sacramento RE zoning: height, setbacks and lot size

In West Sacramento's RE zone, buildings can be up to 30 ft tall, the front setback is 30 ft and the minimum lot size is 2.5 acres (West Sacramento code, read October 2026).

Key points

  • Maximum building height: 30 ft
  • Minimum front setback: 30 ft
  • Minimum side setback: 10 ft
  • Minimum rear setback: 20 ft
  • Minimum lot size: 2.5 acres
  • Maximum lot coverage: 25%

RE is a zoning district in West Sacramento. Every value below was read from the West Sacramento Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in RE

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
30 ft
§ 17.08.030 · code text
Table row “Maximum Height (feet)”, column “RE”: 30(B)
Minimum front setback
30 ft
§ 17.08.030 · code text
Table row “Front”, column “RE”: 30
Minimum side setback
10 ft
§ 17.08.030 · code text
Table row “Interior Side”, column “RE”: 10
Minimum rear setback
20 ft
§ 17.08.030 · code text
Table row “Rear”, column “RE”: 20
Minimum lot size
2.5 acres
§ 17.08.030 · code text
Table row “Minimum Lot Size (square feet, unless otherwise indicated)”, column “RE”: 2.5 acres (A)
Maximum lot coverage
25%
§ 17.08.030 · code text
Table row “Maximum Lot Coverage (% of lot)”, column “RE”: 25

Uses in RE

Uses the code's use tables allow in RE, or allow with a permit. Each links to its page with the code section.

Not on this page

We did not find a general stories, FAR, density limit for RE in the zoning tables we read. The code may still set one elsewhere — check the West Sacramento Municipal Code.

Other West Sacramento zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in West Sacramento's RE zone?

30 ft — West Sacramento Municipal Code § 17.08.030.

What is the minimum front setback in West Sacramento's RE zone?

30 ft — West Sacramento Municipal Code § 17.08.030.

What is the minimum side setback in West Sacramento's RE zone?

10 ft — West Sacramento Municipal Code § 17.08.030.

What is the minimum rear setback in West Sacramento's RE zone?

20 ft — West Sacramento Municipal Code § 17.08.030.

What is the minimum lot size in West Sacramento's RE zone?

2.5 acres — West Sacramento Municipal Code § 17.08.030.

General information, not legal advice.

Ask about a West Sacramento property in RE

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on West Sacramento