Whittier MU-3 zoning: height, setbacks and lot size

In Whittier's MU-3 zone, buildings can be up to 50 ft tall and the front setback is 0 ft (Whittier code, read October 2026).

Key points

  • Maximum building height: 50 ft
  • Minimum front setback: 0 ft
  • Minimum side setback: 0 ft (build-to line: the building must stand at this distance, no gap)
  • Minimum rear setback: 10 ft
  • Maximum floor area ratio (FAR): 1.00 FAR
  • Maximum density: 40 du/ac (mixed use with residential only; community benefits Tier 1 raises it to 50)

MU-3 is a zoning district in Whittier. Every value below was read from the Whittier Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in MU-3

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
50 ft
§ 18.35.030 · code text
Table row “Primary Structures”, column “MU-3”: 50 feet Tier 1 - 60 feet Tier 2 - 75 feet
Minimum front setback
0 ft
§ 18.35.030 · code text
Table row “Front”, column “MU-3”: 0 feet minimum
Minimum side setback
0 ft
Applies: build-to line: the building must stand at this distance, no gap
§ 18.35.030 · code text
Table row “Interior Side”, column “MU-3”: 0 feet minimum 0 feet maximum
Minimum rear setback
10 ft
§ 18.35.030 · code text
Table row “Rear”, column “MU-3”: 10 feet minimum
Maximum floor area ratio (FAR)
1.00 FAR
§ 18.35.030 · code text
Table row “Maximum”, column “MU-3”: 1.00 FAR Tier 1 - 2.00 FAR Tier 2 - 3.00 FAR (see Section 18.35.050 for Tiers)
Maximum density
40 du/ac
Applies: mixed use with residential only; community benefits Tier 1 raises it to 50
§ 18.35.030 · code text
Table row “Maximum”, column “MU-3”: 40 du/ac Tier 1 - 50 du/ac Tier 2 - 60 du/ac (see Section 18.35.050 for Tiers)

Uses in MU-3

Uses the code's use tables allow in MU-3, or allow with a permit. Each links to its page with the code section.

When a different number applies

The code sets other values for particular lots, buildings or locations in MU-3:

  • Maximum building height: 60 ft — community benefits Tier 1 § 18.35.030
  • Maximum building height: 75 ft — community benefits Tier 2 § 18.35.030
  • Maximum floor area ratio (FAR): 2.00 FAR — community benefits Tier 1 § 18.35.030
  • Maximum floor area ratio (FAR): 3.00 FAR — community benefits Tier 2 § 18.35.030
  • Maximum density: 60 du/ac — community benefits Tier 2; mixed use with residential only § 18.35.030

Not on this page

We did not find a general stories, lot size, lot coverage limit for MU-3 in the zoning tables we read. The code may still set one elsewhere — check the Whittier Municipal Code.

Other Whittier zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Whittier's MU-3 zone?

50 ft — Whittier Municipal Code § 18.35.030.

What is the minimum front setback in Whittier's MU-3 zone?

0 ft — Whittier Municipal Code § 18.35.030.

What is the minimum side setback in Whittier's MU-3 zone?

0 ft (build-to line: the building must stand at this distance, no gap) — Whittier Municipal Code § 18.35.030.

What is the minimum rear setback in Whittier's MU-3 zone?

10 ft — Whittier Municipal Code § 18.35.030.

What is the maximum floor area ratio (far) in Whittier's MU-3 zone?

1.00 FAR — Whittier Municipal Code § 18.35.030.

General information, not legal advice.