In Yucaipa's RM-24 zone, generally buildings can be up to 45 feet tall, the front setback is 25 feet min. and the minimum lot size is 2 gross acres, with the conditions listed below (Yucaipa code, read October 2026).

Key points

  • Maximum building height: 45 feet (mixed-use development may exceed this by 20%)
  • Minimum front setback: 25 feet min. (Single-story buildings; the average front setback must be at least 30 feet)
  • Minimum side setback: 10 feet (Single-story buildings)
  • Minimum rear setback: 15 feet (Single-story buildings)
  • Minimum lot size: 2 gross acres
  • Maximum lot coverage: 60%
  • Maximum density: 24 du/ac

RM-24 (High Density Multiple Residential) is a zoning district in Yucaipa. Every value below was read from the Yucaipa Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in RM-24

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
45 feet
Applies: mixed-use development may exceed this by 20%
§ 84.0335 · code text
Table row “Maximum Structure Height”, column “Standard”: 45 feet
Minimum front setback
25 feet min.
Applies: Single-story buildings; the average front setback must be at least 30 feet
§ 84.0335 · code text
Table row “Front Yard Setback (single story)”, column “Standard”: 25 feet min. 30 feet avg.
Minimum side setback
10 feet
Applies: Single-story buildings
§ 84.0335 · code text
Table row “Side Yard Setbacks (single story)”, column “Standard”: 10 feet
Minimum rear setback
15 feet
Applies: Single-story buildings
§ 84.0335 · code text
Table row “Rear Yard Setbacks (single story)”, column “Standard”: 15 feet
Minimum lot size
2 gross acres
§ 84.0335 · code text
Table row “Minimum Lot Size”, column “Standard”: 2 gross acres
Maximum lot coverage
60%
§ 84.0335 · code text
Table row “Maximum Lot Coverage”, column “Standard”: 60%
Maximum density
24 du/ac
§ 84.0335 · code text
Table row “Maximum Housing Density”, column “Standard”: 24 du/ac

When a different number applies

The code sets other values for particular lots, buildings or locations in RM-24:

  • Minimum front setback: 35 feet min. — Multi-story buildings; the average front setback must be at least 40 feet § 84.0335
  • Minimum side setback: 20 feet — Multi-story buildings § 84.0335
  • Minimum rear setback: 20 feet — Multi-story buildings § 84.0335

Not on this page

We did not find a general stories, FAR limit for RM-24 in the zoning tables we read. The code may still set one elsewhere — check the Yucaipa Municipal Code.

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Yucaipa's RM-24 zone?

45 feet (mixed-use development may exceed this by 20%) — Yucaipa Municipal Code § 84.0335.

What is the minimum front setback in Yucaipa's RM-24 zone?

25 feet min. (single-story buildings; the average front setback must be at least 30 feet) — Yucaipa Municipal Code § 84.0335.

What is the minimum side setback in Yucaipa's RM-24 zone?

10 feet (single-story buildings) — Yucaipa Municipal Code § 84.0335.

What is the minimum rear setback in Yucaipa's RM-24 zone?

15 feet (single-story buildings) — Yucaipa Municipal Code § 84.0335.

What is the minimum lot size in Yucaipa's RM-24 zone?

2 gross acres — Yucaipa Municipal Code § 84.0335.