110.5 Natural Gas Central Furnaces, Cooking Equipment, Pool and Spa Heaters,… — 2025 California Energy Code
California Energy Code (Title 24, Part 6) · 2025 edition · updated 2026-10-19 · California
Cite as: 2025 California Energy Code (Title 24, Part 6) § 110.5 · Effective January 1, 2026 · Official source: Building Standards Commission
Any natural gas system or equipment listed below may be installed only if it does not have a continuously burning pilot light:
(a) Fan-type central furnaces.
(b) Household cooking appliances.
Exception to Section 110.5(b): Household cooking appliances without an electrical supply voltage connection and in which each pilot consumes less than 150 Btu/hr.
(c) Pool heaters.
(d) Spa heaters.
(e) Indoor and outdoor fireplaces.
Note: Authority: Sections 25213, 25218, 25218.5, 25402 and 25402.1, Public Resources Code . Reference: Sections 25007, 25008, 25218.5, 25310, 25402, 25402.1, 25402.4, 25402.8, and 25943, Public Resources Code.
Continue researching
Related topics
State and federal sources. Edit the document title or filters, then run your search.
Get a plain-English answer with a citation back to this text.
Ask AI about this code