Skip to content

Earlier editions: 20222019

Appendix A4

A4.602 Residential Occupancies Application Checklist — 2025 California Green Building Standards Code

California Green Building Standards Code (Title 24, Part 11) · 2025 edition · updated 2026-10-19 · California

CBSC: official editions, supplements and errata

Cite as: 2025 California Green Building Standards Code (Title 24, Part 11) § A4.602 · Effective January 1, 2026 · Official source: Building Standards Commission

FEATURE OR MEASURE LEVELS
APPLICANT TO SELECT ELECTIVE MEASURES
VERIFICATIONS
ENFORCING AGENCY TO SPECIFY
VERIFICATION METHOD
FEATURE OR MEASURE Mandatory Prerequisites and electives1 Prerequisites and electives1 Enforcing
Agency

All
Installer or
Designer

All
Third
party

All
FEATURE OR MEASURE Mandatory Tier 1 Tier 2 Tier 2 Tier 2 Tier 2
PLANNING AND DESIGN
Site Selection
A4.103.1 A site which complies with at least one of the following
characteristics is selected:
1. An infill site is selected.
2. A greyfield site is selected.
3. An EPA-recognized Brownfield site is selected.










A4.103.2 Facilitate community connectivity by one of the following
methods:
1. Locate project within a1/4-mile true walking distance of at least 4
basic services;
2. Locate project within1/2-mile true walking distance of at least 7
basic services;
3. Other methods increasing access to additional resources.










Site Preservation
A4.104.1An individual with oversight responsibility for the project
has participated in an educational program promoting
environmentally friendly design or development and has provided
training or instruction to appropriate entities.
Deconstruction and Reuse of Existing Materials
A4.105.2 Existing buildings are disassembled for reuse or recycling of
building materials. The proposed structure utilizes at least one of the
following materials which can be easily reused:
1. Light fixtures
2. Plumbing fixtures
3. Doors and trim
4. Masonry
5. Electrical devices
6. Appliances
7. Foundations or portions of foundations
Site Development
4.106.2A plan is developed and implemented to manage storm water
drainage during construction.
4.106.3Construction plans shall indicate how site grading or a
drainage system will manage all surface water flows to keep water
from entering buildings.
4.106.4.1Provide capability for electric vehicle charging for one- and
two-family dwellings; townhouses with attached private garages in
accordance with Section 4.106.4.1.
4.106.4.2 Provide capability for electric vehicle charging for
multifamily dwellings and hotels/motels in accordance with Sections
4.106.4.2.2 and 4.106.4.2.6.
4.106.4.3 Provide capability for electric vehicle charging for existing
parking lots or new parking lots for existing residential buildings,
hotels/motels in accordance with Section 4.106.4.3, as applicable.
4.106.4.4Provide bicycle parking facilities as noted below or meet a
local ordinance, whichever is more stringent. Number of bicycle
parking spaces may be reduced, as approved by the enforcing agency,
due to building site characteristics, including but not limited to,
isolation from other development.
1. Provide short-term bicycle parking, per Section 4.106.4.4.1.
2. Provide long-term bicycle parking for multifamily buildings per
Section 4.106.4.4.2.
3. Provide long-term bicycle parking for hotel and motel buildings,
per Section 4.106.4.4.3.










Explained in plain English

Guides that cite this section.

Get a plain-English answer with a citation back to this text.

Ask AI about this code
▸Contents — California Green Building Standards Code (Title 24, Part 11)

GoCodebook provides public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.