About this appendix: This appendix addresses the considerations that need to be taken into account by building officials regarding the placement and installation of nonsewered sanitation systems in buildings. This appendix would permit the installation of a of these systems and provide an exception to the general requirement in the California Plumbing Code and this code that sanitation devices be connected to the building drainage system.
CG101—GENERAL
CG101.1 Applicability.¶
The provisions of this chapter shall apply to the installation of nonsewered sanitation systems.
CG101.2 System requirements.¶
Nonsewered sanitation systems shall comply with ANSI/CAN/IAPMO/ISO CG106.1.
CG102—DEFINITIONS
CG102.1 General.¶
For purposes of this chapter, the following definitions shall apply:
CONDITIONED SPACE. An area, room or space normally occupied and being heated or cooled for human habitation by any equipment.
NONSEWERED SANITATION SYSTEM. A prefabricated integrated sewage treatment unit that is not connected to a public sewer or private sewage disposal system.
CG103—INSTALLATION
CG103.1 General.¶
The installation of nonsewered sanitation systems shall be in accordance with the manufacturer’s installation instructions and with Sections CG103.2 through CG103.7.
CG103.2 Operating conditions.¶
A nonsewered sanitation system in either a conditioned or unconditioned space shall be installed where the ambient temperature, ambient humidity and altitude ( atmospheric pressure ) are in accordance with the manufacturer’s installation instructions or product listing.
CG103.3 Clearances for servicing and maintenance.¶
A nonsewered sanitation system shall be located to permit access and sufficient clearance for service and maintenance. Unless otherwise specified by the manufacturer’s installation instructions, not less than 30 inches (762 mm) in depth, width and height of working space shall be provided at any access panel.
CG103.4 Backflow prevention.¶
A domestic water supply connection to a nonsewered sanitation system shall be protected in accordance with Section P2902.
CG103.5 Effluent storage.¶
Any container or vessel for the storage of effluent discharged from a nonsewered sanitation system and not integral to such system shall be installed in accordance with Section P2910.9.
CG103.6 Systems employing combustion.¶
A nonsewered sanitation system employing combustion shall comply with the California Mechanical Code .
CG103.7 Connection to plumbing system not required.¶
A nonsewered sanitation system is not required to be connected to the sanitary drainage system of the building or premises.
CG104—MANUAL REQUIRED
CG104.1 Operation and maintenance manual.¶
Nonsewered sanitation systems shall have an operation and maintenance manual provided by the manufacturer.
CG105—SYSTEM OUTPUT
CG105.1 General.¶
The use or disposal of all substances exiting the nonsewered sanitation system shall be determined by the authority having jurisdiction.
CG106—REFERENCED STANDARDS
CG106.1 General.¶
See Table CG106.1 for standards that are referenced in various sections of this appendix. Standards are listed by the standard identification with the effective date, the standard title and the section or sections of this appendix that reference the standard.
TABLE CG106.1—REFERENCED STANDARDS
| STANDARD ACRONYM |
STANDARD NAME | SECTIONS HEREIN REFERENCED |
|---|---|---|
| ANSI/ |
Non-sewered sanitation systems — Prefabricated integrated treatment units — General safety and performance requirements for design and testing |
CG101.2 |
APPENDIX CH – PRIVATE SEWAGE DISPOSAL
(Matrix Adoption Tables are nonregulatory, intended only as an aid to the code user. See Chapter 1 for state agency authority and building applications.)
| Adopting agency | BSC | BSC-CG | SFM | HCD 1 | HCD 2 | HCD 1/AC | DSA AC | DSA SS | DSA SS/CC | OSHPD 1 | OSHPD 1R | OSHPD 2 | OSHPD 3 | OSHPD 4 | OSHPD 5 | BSCC | DPH | AGR | DWR | CEC | CA | SL | SLC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Adopt entire chapter | |||||||||||||||||||||||
| Adopt entire chapter as amended (amended sections listed below) | |||||||||||||||||||||||
| Adopt only those sections that are listed below | |||||||||||||||||||||||
| Chapter / Section | |||||||||||||||||||||||
Continue researching
Related topics
State and federal sources. Edit the document title or filters, then run your search.
Get a plain-English answer with a citation back to this text.
Ask AI about this code