Earlier editions: 2026-07
Oakdale Municipal Code Ch. 41 Temporary Heating and Cooking Operations
Oakdale Municipal Code · 2026-10 edition · updated 2026-10-04 · Oakdale
Cite as: Oakdale Municipal Code Chapter 41 · Text as of 2026-10-04
TEMPORARY HEATING AND COOKING OPERATIONS
PORTABLE FUEL-FIRED HEATING APPLIANCES
Section 4103.1 of the 2025 California Fire Code is hereby amended to read as follows:
Portable unvented fuel-fired heating equipment which produces carbon monoxide (CO) shall be prohibited in any occupancy or building.
| Exception: Buildings or structures under construction as outlined in chapter 33 of the 2025 California Fire Code. |
|---|
| CHAPTER 50 |
|---|
| HAZARDOUS MATERIALS |
| GENERAL PROVISIONS |
Material Classification.
Section 5001.2 of the CFC, the definition of "Hazardous Materials," is hereby amended to read as follows:
Definition: Hazardous materials are those chemicals or substances which are physical hazards or health hazards as defined and classified in Chapter 50, or as defined in the California Health and Safety Code, Division 20, Chapter 6.95, commencing with Section 25500, whether the materials are in useable or waste condition.
NFPA 704 placards shall be required on all commercial buildings/structures with hazardous materials as required by the Fire Chief.
Deposits of Hazardous Materials; Cleanup, Abatement, or Mitigation Required; Liability for Costs.
Section 5003.3.1.4 of the 2025 California Fire Code is hereby amended to read as follows:
Responsibility for Cleanup. The person, firm or corporation responsible for an unauthorized discharge shall institute and complete all actions necessary to remedy the effects of such unauthorized discharge, whether sudden or gradual, at no cost to the jurisdiction. When deemed necessary by the City Manager and/or Fire Code Official and/or Chief, cleanup may be initiated by the Fire Department or by an authorized individual or firm. Costs associated with such cleanup shall be borne by the owner, operator or other person responsible for the unauthorized discharge. The remedy provided by this section shall be in addition to any other remedies provided by law.
For purposes of this section, costs incurred by the City of Oakdale and/or fire contract personnel shall include, but shall not necessarily be limited to, the following: actual labor costs of City of Oakdale personnel, and/or fire contract personnel including worker's compensation benefits, fringe benefits, administrative overhead; cost of equipment operation; cost of materials obtained directly by the City of Oakdale and/or fire contract personnel; and cost of any contract labor and materials. The authority to recover costs under this section shall not include actual fire suppression services that are normally or usually provided by the Fire Department.
| CHAPTER 55 |
|---|
| CTYOGENIC FLUIDS |
| STORAGE |
Location.
Section 5504.3.1.1.3 of the 2025 California Fire Code is hereby amended by adding the following:
Prohibited Storage Location. Storage of flammable cryogenic fluids in stationary containers outside of buildings is prohibited within the limits established by law (table 5504.3.1.1). All R-1, R-2 and R-3 zoning designations as identified in the municipal code.
| CHAPTER 56 |
|---|
| EXPLOSIVES AND FIREWORKS GENERAL |
Permit Required for Explosives.
Section 5601.2 of the 2025 California Fire Code is amended to read:
When permits are required to be issued by the City of Oakdale, the City Manager may grant the authority to the agency having enforcement jurisdiction. Permits shall be obtained:
To possess, store, sell, display or otherwise dispose of explosive materials at any location.
To transport explosive materials.
To use explosive materials.
To operate a terminal for handling explosive materials.
Notice of New Storage Sites.
Section 5603.8. of the 2025 California Fire Code is added to read:
When a new explosive material storage location, including a temporary job site, is established, the local law enforcement agency and Fire Department shall be notified immediately of the type, quantity and location of explosive materials at the site.
General.
Section 5604.1 of the 2025 California Fire Code is amended to read:
Explosive materials shall not be manufactured within the City limits of Oakdale.
Explosive Materials Prohibited and Limited Acts.
Section 5604.1.2 of the 2025 California Fire Code is added to read:
The storage of explosives and blasting agents is restricted to those areas of the City zoned as Heavy Industrial Zone (M-2).
EXCEPTION:
Temporary storage for use in connection with approved blasting operations conducted in accordance with all applicable provisions of this article.
Wholesale and retail storage and display of ammunition and gunpowder shall be in accordance with Title 19 California Code of Regulations, Chapter 10.
Manufacturing of Fireworks.
Section 5605.1 of the 2025 California Fire Code is amended to read:
The manufacturing of fireworks is prohibited in the City of Oakdale.
Fireworks Displays, Permits and Appeal Process.
Section 5608.2 of the 2025 California Fire Code is added to read as follows:
Permits. The Fire Code Official and/or Chief may grant the permit as applied for, or with condition thereto, unless he/she finds that to do so would be contrary to the public health, safety, or welfare. The decision of the Fire Code Official and/or Chief shall be in writing and shall be mailed, postage prepaid, to the applicant.
Section 5608.2.1 of the 2025 California Fire Code is added to read as follows:
Appeals. The decision of the Fire Code Official and/or Chief, in acting on an application for permission to conduct a public display in accordance with the provisions of this section may be appealed to the City Manager. Notice of an appeal of the Fire Code Official and/or Chief's decision shall be filed by the applicant with the City Clerk within 10 days after the date of the decision. Upon failure to file such notice within the ten-day period, the action of the Fire Code Official and/or Chief shall be final and conclusive. The applicant may appeal the decision of the City Manager to the City Council by filing a notice of appeal to the City Clerk within 10 days after the date of the City Manager's decision. Upon failure to file such notice within the ten-day period, the action of the City Manager, or his/her designee, shall be final and conclusive.
Section 5608.3 of the 2025 California Fire Code is hereby added to read as follows:
Fee. A nonrefundable fee as established by resolution of the City Council from time to time shall accompany every application for permission to conduct a public display of fireworks.
Section 5608.4 of the 2025 California Fire Code is hereby added to read as follows:
Sales. It shall be unlawful to engage in the sale of "Safe and Sane" fireworks in the City of Oakdale without first having secured a permit to do so.
(1) The total number of sales permits issued in any given year shall be limited to one per each 2,500 population or portion thereof. The sales permits will be limited to a total of those issued in 1999 - 15. No additional permits will be issued until the population exceeds the limited amount.
(2) Sales permits for the sale of "Safe and Sane" fireworks in the City of Oakdale shall be issued only to local nonprofit organizations.
(A) A "nonprofit organization" shall mean any nonprofit association, club, or corporation organized for veteran, patriotic, welfare, religious, civic betterment, youth or charitable purposes, as defined by Section 501(c) of the Internal Revenue Code of the United States, or affiliated with a public school located within the city limits of Oakdale. Each new organization shall provide the City with a copy of their letters of incorporation as proof of their nonprofit status. Existing organizations shall submit verification of current corporation status from the State of California Secretary of State's Office. Those organizations that are an integral part of a recognized national organization having tax exempt status must provide IRS written verification of such status. All applications will be subject to additional verification with the State of California and IRS if nonprofit status comes into question.
(B) Public school organizations shall provide current written verification of affiliation from the school each year.
(C) A "local nonprofit organization" must have its principal and permanent meeting place in the City of Oakdale. The organization must have obtained nonprofit status and have been organized and established in the City of Oakdale for a minimum of one continuous year preceding the filing of the application for permit. The organization must also have a bona fide membership of at least 10 members who reside in the City of Oakdale, which will be verified each year. Applications shall be signed by two bona fide officers of the eligible organization, wherein the officer, on behalf of the organization and its agents, agrees to abide by state laws, administrative regulations, and all stipulations of this Code and the permit if permission to operate a fireworks stand is granted to the organization.
(D) If any of the above items fail to be met at the time of application, the organization's application shall be denied.
(3) Sales permits for retail sales of "Safe and Sane" fireworks in the City of Oakdale issued pursuant to provision of this Code are not transferable by the holder of the permit. The sales permits may be used only by the organization to which they are issued. Violations will result in the immediate loss of the organization's sales permit.
(4) All applications for sales permits shall be in writing to the Fire Code Official and/or Chief on forms supplied by the Fire Department. Applications may only be filed during normal business hours from April 1 of each year up to and including April 30 of the same year, at which time the filing period for that year will close. A separate sales permit shall be required for each proposed location of a fireworks stand. Each organization may file an application for one sales permit for which there is only one tax ID number.
(5) Applications shall set forth the proposed location of the fireworks stand including the nine-digit parcel number (APN) of the Stanislaus County Assessor, a site map, and other information as may be required by the Fire Code Official and/or Chief.
(6) Applicants for sales permits shall be notified by May 15 of each year by the Fire Code Official and/or Chief of approval or disapproval of such application. Sales permits will be issued after final inspection of the stand reveals compliance with all state and local regulations. Organizations shall not open for sales prior to the final inspection of their stand.
(7) Every application shall be accompanied by proof of insurance as specified in Section 3-1.128. Other items required at the time of application will be the organization's verification of eligibility as stated in 2(A) above, list of bona fide members, and current written permission signed by the property owner of record (with respect to lessee permission, approval shall be in the sole discretion of the Fire Code Official and/or Chief) to sell fireworks at that location. Organizations representing public schools, as stated in 2(B) above, require written verification from the school of their affiliation.
(8) Any local nonprofit organization as defined herein may make application for a sale permit but pre-approved (continuously permitted since 1999) organizations will have first option for a permit.
(A) When additional sales permits are authorized and all current pre-approved organizations have applied for such permits, a lottery will be held to fill any vacancies.
(B) This lottery will be held on the first day following the last day of the filing period specified in Paragraph (4) and will include the names of all new local nonprofit organizations that have filed a complete application within the said filing period. If first day following the last day of the filing period falls on a weekend, the lottery will be held on the next business day.
(C) One organization will be drawn for each available vacancy. If the organization whose name is drawn declines the permit, another name will be drawn until each vacancy is filled.
(D) Any organization having an approved application that fails to open their stand for that sales year will automatically forfeit their permit and a new organization will be chosen the following year provided a permit is available.
Sales, Storage, Use and Handling of Fireworks.
Section 5608.5 of the 2025 California Fire Code is hereby added to read as follows:
5608.5 General. Sales, storage, use, and handling of fireworks shall be in accordance with this section.
- Sales. Retail sale or display with the intent to sell fireworks is limited to State of California Fire Marshal approved and labeled "Safe and Sane" fireworks within the City of Oakdale by State of California licensed retailers, provided a permit to sell those fireworks has been approved and obtained from the Fire Code Official and/or Chief. Fireworks may be sold or offered for sale from 12:00 noon to 10:00 p.m. on June 28; 9:00 a.m. to 10:00 p.m. on June 29 through July 5; and 9:00 a.m. to 12:00 noon on July 6.
The storage of fireworks within the City of Oakdale is limited to State of California Fire Marshal-approved and labeled "Safe and Sane" fireworks by State of California licensed wholesalers and retailers.
(1) Wholesale Storage. Wholesalers may store "Safe and Sane" fireworks within the City of Oakdale solely during the period of June 1 through July 31 of each year. Storage facilities shall comply with H1 occupancy classification requirements as defined by the Uniform Building Code.
(2) Retailers Storage. Retailers may store "Safe and Sane" fireworks within the City of Oakdale solely during the period of June 22 through July 15 of each year. "Safe and Sane" fireworks that are not being sold or displayed with the intent to sell shall be stored solely in the following manner:
(A) Within the permitted fireworks stand with a responsible adult on the premises at all times.
(B) In a completely enclosed and locked utility type trailer constructed of 1/4-inch plywood or other approved noncombustible material.
(C) In a completely detached garage on residential property with a minimum ten-foot clearance from other structures or property lines, there shall be no open-flame or spark-producing equipment, or Class 1 flammable liquids stored or used within in the garage.
(D) Fireworks shall not be stored within 40 feet of any building classified or used as a public or private school, day-care facility, residential care facility, hospital, place of detention, public oil/gas station, or public garage, or any place of public assembly that can accommodate 50 or more persons.
(E) In an approved and permitted fireworks warehouse.
(3) Temporary Fireworks Stands.
(1) All retail sales of "Safe and Sane" fireworks shall be permitted only from within a temporary fireworks stand and sales from any other building or structure is hereby prohibited.
(2) City Business License, Fire Department Permit and State License shall be displayed in the fireworks stand during hours of operation.
(3) Temporary fireworks stand shall not be set up before application for permit has been approved nor earlier than June 14.
(4) The fireworks stands shall be located at least 20 feet from other structures.
(5) Zoning of property, in which the fireworks stand will be located, shall be in limited to C-1, and C-2 Zones.
(6) Fireworks shall not be stored, sold, offered for sale, or discharged within 100 feet of a location where gasoline, LPG, other Class 1 flammable liquids or flammable gasses are stored or dispensed.
(7) All unsold stock and accompanying litter shall be removed from the location by 5:00 p.m. on the sixth day of July.
(8) The fireworks stand shall be removed from the temporary location by 12:00 noon on the 12th day of July, and all accompanying litter shall be cleared from said location by said time and date.
(9) A penalty of $100 per day will be assessed to the permittee of any fireworks stand not removed by 12:00 noon on the 12th day of July.
(4) Safety Precautions.
(1) No person under the age of 18 shall sell, or handle for sale, any classification of fireworks.
(2) No person under the age of 18 shall purchase or be allowed to purchase any classification of fireworks.
(3) Smoking, open-flame, and spark-producing equipment shall be prohibited for a distance of 20 feet around any fireworks stand.
(4) Dry grass, weeds, trash, and other combustible material shall be removed for a distance of 20 feet around any fireworks stand.
(5) Fireworks shall not be discharged within 50 feet of a fireworks stand.
(5) Stand Construction.
(1) Merchandise may be displayed in approved glass-enclosed counters or showcases; or
(2) Merchandise may be displayed in stands constructed in the following manner:
(A) Walls and roof shall be of plywood at least one-fourth-inch thick or of an approved noncombustible material.
(B) The stand shall be provided with a roof.
(C) Walls shall extend to a minimum height of six feet eight inches on at least three sides. These three sides shall be without openings, except for an exit door.
(D) An exit door with a minimum size of 24 inches in width and six feet in height shall be provided in each stand. Exits shall be maintained clear and unobstructed at all times.
(E) The front wall of the stand shall provide a physical barrier not less than 18 inches in height between the public and the merchandise on display.
(F) Approved "NO SMOKING" signs shall be prominently displayed in and on the stand.
(G) Approved "NO SALES TO PERSONS UNDER THE AGE OF 18" signs shall be prominently displayed in the stand.
(H) An approved fire extinguisher having a minimum U.L. classification of 2A shall be located in the stand, near the exit and readily accessible.
(I) Sellers of fireworks shall comply with all rules and regulations of Title 19 of the California Code of Regulations and with the rules and regulations of the Fire Code Official and/or Chief.
(J) Stands will be limited to 24 feet by eight feet or 192 square feet in size. Pre-existing stands as identified by the fireworks suppliers shall retain the right to operate their oversized stands, without change, until said stand or organization forfeits or loses their operating permit. A copy of said list shall remain on file with the Fire Code Official and/or Chief.
(6) Operation of Fireworks Stand Only by Permittee.
(1) It is unlawful for the permittee organization to allow any person or entity other than the permittee organization to operate the fireworks stand for which the permit is issued, whether by agreement, assignment or otherwise, or to otherwise participate in the profits of the operation of such fireworks stand. Violations will result in the immediate loss of the organization's permit.
(2) It is unlawful for a nonprofit organization to allow any person other than the individuals who are members of the permittee organization, their spouses or adult children, or volunteers to whom no compensation is paid, to sell or otherwise participate in the sale of fireworks at such fireworks stand.
(3) It is unlawful for a nonprofit organization to pay any consideration to any person for selling or otherwise participating in the sale of fireworks at such fireworks stand, except the hiring of a night watchman or security officer.
Revocation of Permit and Seizure of Fireworks.
Section 5608.6 of the 2025 California Fire is hereby added to read as follows:
The Fire Code Official and/or Chief, or his/her designee, may revoke, immediately and without notice or hearing, the "Safe and Sane" fireworks sales permit of any location or organization when any of the provisions of Sections 5608.2-5608.5 are violated. The Fire Code Official and/or Chief shall inform the permittee that permittee may seek review of the Fire Code Official and/or Chief's decision, by the City Manager, on the next business day. At the earliest opportunity on the next business day after revocation, the Fire Code Official and/or Chief shall provide the City Manager with written notice that a fireworks sales permit has been revoked, including the name of the permittee and a brief statement of the grounds for revocation. If requested by the permittee, the City Manager, or his/her designee, shall meet with the permittee and the Fire Code Official and/or Chief, or his/her designee, that day to review the Fire Code Official and/or Chief's decision. The decision of the City Manager shall be final.
Revocation of Permit and Seizure of Fireworks.
Section 5608.6.1 of the 2025 California Fire Code is hereby added to read as follows:
Revocation of any sales permit will be effective for that calendar year.
Fireworks Displays Insurance Required.
Section 5608.7 of the 2025 California Fire Code is hereby added to read as follows:
The permittee shall furnish a certificate of insurance for each policy required, executed by the company issuing such policy. Such policies shall contain a provision which holds the City as an additional insured and declaring said insurance to be primary and that no other insurance carried by an insured party shall be called upon for contribution. Notwithstanding any other provision of this section, the failure of the permittee to carry such insurance during the time covered by such permit shall automatically revoke the permit as of the date of expiration of such insurance policy or policies. A payment of $50 shall be made to the City before any such revoked permit may be reinstated.
The permittee/licensee shall carry general liability insurance with a minimum limit of liability per occurrence of $1,000,000 for bodily injury and $100,000 for property damage, or $1,000,000 combined single-limit. The certificate of insurance shall include the following coverages and indicate the policy aggregate limit applying to: premises and operations, broad form contractual, and products and completed operation.
The permittee/licensee shall agree to hold the City of Oakdale, its agents, officers, employees, and volunteers harmless from and save, defend, and indemnify them against any and all claims, losses, liabilities, and from every cause, including but not limited to injury to person or property or wrongful death, with the indemnity to include reasonable attorney fees and all costs and expenses arising directly or indirectly out of any act or omission of permittee arising out of any activity authorized by the permit.
The permittee/licensee shall provide at its own expense and maintain at all times the specified insurance policies with insurance companies approved by the State of California and shall provide evidence of such insurance to the City. The policies or certificates thereof shall provide that, 30 days prior to cancellation or material change in the policy, notices of same shall be given to the Finance Director of the City by registered mail, return receipt requested.
Possession, Sales, Use or Discharge of Dangerous Fireworks.
Section 5608.8 of the 2025 California Fire Code is hereby added to read as follows:
(a) For purposes of this section, dangerous fireworks are those fireworks specified as such in the State Fireworks Law, Section 12505 of the California Health and Safety Code, and such other fireworks as may be determined to be dangerous by the State Fire Marshal.
(b) It shall be unlawful for any person to possess, sell, use or discharge dangerous fireworks, or a dangerous firework kit, unless a permit authorizing such possession, sale, use or discharge has been issued by the Fire Code Official and/or Chief to the person, using, selling, discharging or found in possession of said fireworks or kits, and unless such person is in possession of a valid pyrotechnic operator's license issued by the Office of the State Fire Marshal. The Fire Code Official and/or Chief may establish reasonable rules and regulations for governing issuance of a firework permit and may issue the same subject to payment of a fee as established by the City Council from time to time.
(c) The Fire Code Official and/or Chief, or designee, shall seize, take, remove or cause to be removed, at the expense of the owner, all stocks of dangerous fireworks offered or exposed for sale, stored or held in violation of this chapter.
| CHAPTER 57 |
|---|
| FLAMMABLE AND COMBUSTIBLE LIQUIDS STORAGE |
Restricted locations of flammable and Combustible Liquids in Tanks.
Section 5704.2.9.6.1 of the 2025 California Fire Code is hereby amended to read:
Storage of Class I and II liquids in aboveground tanks outside of buildings is prohibited in all zones except General Commercial (C-2), Limited Industrial (L-M), Light Industrial (M-1), and Heavy Industrial (M-2), with the exception of protected tanks designed, installed and maintained in accordance with the 2025 California Fire Code. The provisions of this section shall not apply to facilities for the production, generation, or transmission of electric energy that provide power to entities furnishing retail electrical services to the general public within the City of Oakdale.
Maintenance of Protected Aboveground Tanks.
Section 5704.2.9.6.1.2 of the 2025 California Fire Code is hereby added to read as follows at the end of the paragraph:
Protected aboveground tanks and connected piping shall be maintained in a safe operating condition. Protected aboveground tanks shall be maintained in accordance with their listings. Damage to protected aboveground tanks shall be repaired using material having equal or greater strength and fire resistance or the protected aboveground tank shall be replaced or taken out of service.
Manufacture of Ethanol and Biodiesel at Residential Occupancies.
Section 5704.3.4.2 number 7 of the 2025 California Fire Code is hereby amended by adding:
7.1: The manufacture and storage of biodiesel is prohibited in residential occupancies…¶
7.2: The manufacture and storage of ethanol is prohibited in residential occupancies…¶
Flammable and Combustible Liquids Dispensing, Use, Mixing and Handling.
Operating Heating, Lighting, and Cooking Appliances Prohibited.
Section 5705.3.3 of the 2025 California Fire Code is hereby amended to read as follows:
Heating, lighting or cooking appliances which utilize Class I,II or III liquids shall not be operated within a building or structure within the city limits.
Flammable and Combustible Liquids Special Operations.
Locations where aboveground tanks are prohibited.
Section 5706.2.4.4 of the 2025 California Fire Code is hereby amended to read:
Storage of Class I and II liquids in aboveground tanks is prohibited in all zones except General Commercial (C-2), Limited Industrial (L-M), Light Industrial (M-1), and Heavy Industrial (M-2), with the exception of protected tanks designed, installed and maintained in accordance with the 2019 California Fire Code. The provisions of this section shall not apply to facilities for the production, generation, or transmission of electric energy that provide power to entities furnishing retail electrical services to the general public within the City of Oakdale.
Location of Bulk Plants for Storage of Flammable and Combustible Liquids.
Section 5706.4.1 of the 2025 California Fire Code is hereby amended to by adding the following at the end of the paragraph:
The construction of new bulk plants for storage of flammable or combustible liquids is restricted to areas of the City of Oakdale zoned Limited Industrial (L-M). All existing nonconforming bulk plants for storage of flammable or combustible liquids, which substantially comply with the requirements of this Code, may be continued in use.
Location - Transfer Operations.
Section 5706.5 of the 2025 California Fire Code is hereby adopted by reference, in addition to the following:
Bulk Transfer and Process Transfer Operations. Bulk transfer and process transfer operations shall be in approved locations. Tank cars shall be unloaded only on private sidings or railroad siding facilities equipped for transferring flammable or combustible liquids. Tank vehicle and tank car transfer facilities shall be separated from buildings, aboveground tanks, combustible materials, property lines, streets, alleys or public ways by a distance of twenty (25) feet (7620 mm) for Class I liquids and fifteen (15) feet (4572 mm) for Class II and III liquids measured from the nearest position of any loading or unloading valve.
Tank vehicles and tank cars shall be unloaded as soon as possible after arrival at point of delivery and shall not be used as storage tanks. Unless otherwise approved, a tank car shall not be allowed to remain on a siding at the point of delivery for more than twenty-four (24) hours while connected for transfer operations.
Section 5706.5.1.1 of the 2025 California Fire Code is hereby amended by adding the following:
Tank Vehicles delivering to or receiving from flammable and combustible liquid tanks shall stand entirely on private property. Dispensing into any Tank Truck cargo tank with service station dispensing facilities is prohibited.
| CHAPTER 61 |
|---|
| LIQUEFIED PETROLEUM GASES GENERAL |
Permits and Plans for Liquefied Petroleum Gases.
Section 6101.2 of the 2025 California Fire Code is hereby amended to read as follows:
Permits shall be required as set forth in Sections 105.6 and 105.7.
EXCEPTION:
Containers not exceeding a five-gallon water capacity, used for "barbecue" cooking, when used and stored outside of buildings.
Approved containers not exceeding 16.4 ounces when displayed for sale in mercantile occupancies.
Factory-installed containers for recreational vehicles not exceeding ten-gallon water capacity.
Factory-installed tanks that are permanently attached to recreational vehicles.
Distributors shall not fill an LP-gas container for which a permit is required unless the Fire Code Official has issued a permit for installation for that location.
Installation of Equipment.
Section 6103.1.1 of the 2025 California Fire Code is herby added to read as follows:
Prohibited. LP-gas installations pertinent to systems are not permitted in any residential (R) zones regardless of water capacity.
Liquid Petroleum Gases Location of LP-Containers.
Outside Storage and use of Liquefied Petroleum-Gases.
Section 6104.1 of the 2025 California Fire Code is amended as follows:
The outside storage of liquefied petroleum gas (LP-gas) shall conform to the provisions of the City of Oakdale Zoning Ordinances. The outside storage and use of liquefied petroleum gases is restricted as specified in this section.
Storage and dispensing of LP-gas for resale purposes, into approved containers and vehicles, is restricted to those areas of the City of Oakdale zoned as Neighborhood Commercial (C-1), General Commercial (C-2), Limited Industrial (L-M), Light Industrial (M-1), and Heavy Industrial (M-2), and, in addition thereto, to other commercially zoned properties used as automotive service stations. Only qualified persons shall perform dispensing.
Dispensing of LP-gas for private use is restricted to those zones identified in Subsection 1, and when approved by the Building Official and/or Fire Code Official and/or Chief, may be permitted in those areas of the City of Oakdale zoned Neighborhood Commercial (C-1), General Commercial (C-2), Limited Industrial (L-M), Light Industrial (M-1), and Heavy Industrial (M-2). Only qualified persons shall perform dispensing.
For cooking, lighting, or heating in a building, only on a property that does not have natural gas service existing on a boundary line of said property or when prohibition of such storage would cause undue hardship.
For temporary use on construction sites, when authorized by the Building Official and/or Fire Code Official and/or Chief.
For use as an alternative fuel supply for an emergency standby generator, when authorized by the Building Official and/or Fire Code Official and/or Chief.
For use with certain mobile vending and certain commercial barbecue equipment and other specific uses when authorized by the Building Official and/or Fire Code Official and/or Chief.
For use by artisans in pursuit of their trade, when authorized by the Building Official and/or Fire Code Official and/or Chief.
Storage of portable containers awaiting exchange may be permitted in commercially zoned areas of the City of Oakdale, including those zoned General Commercial (C-2), when approved by the Building Official and/or Fire Code Official and/or Chief and stored in accordance with Section 3809. Such storage shall be located a minimum of 20 feet from any fuel dispenser.
The aggregate capacity for any one installation shall not exceed 2,000 gallons, except that in particular installations this capacity limit may be altered by the Building Official and/or Fire Code Official and/or Chief, after consideration of special features such as topographical conditions, nature of occupancy, proximity of building, capacity of proposed tanks, degree of private fire protection to be provided, and facilities of the local Fire Department.
Separation from means of egress. Containers stored inside or outside buildings frequented by the public shall be located not less than 10 feet from any exit door or building opening, when only one exit is provided from the building or area, and not less than five feet from any exit door or building opening, when two or more exits are provided from the building or area.
| APPENDIX D |
|---|
| FIRE APPARATUS ACCESS ROADS |
Scope.
Appendix D Section D101.1 is amended by adding:
This appendix shall only be enforced on private roadways, property and streets not public roadways.
Fire Apparatus Access and Gates.
Appendix D Section D103.5(1) of the CFC is amended by adding:
Where a fire apparatus road consists of a divided roadway, the gate width shall not be less than 15 feet.
Appendix D Section D103.5(6) of the CFC is amended by adding:
Manual opening access gates may not be locked with a chain and padlock unless a Knox padlock is installed in the chain. Dual keyed access for the Police Department shall be required.
Appendix D Section D103.5(5) of the CFC is amended by adding:
Electric gates shall be operable by means of a Knox key switch accessible by both police and fire. Electric gates at housing complexes, gated communities or rental storage facilities shall also be dual equipped with Opticom strobe light system or as required by the Fire Chief. All Gate shall automatically open upon power failure.