Title 14 — BUILDINGS AND CONSTRUCTION
Pasadena Municipal Code Ch. 14.04 Building Code and Related Codes
Pasadena Municipal Code · 2026-10 edition · updated 2026-10-04 · Pasadena
Cite as: Pasadena Municipal Code Chapter 14.04 · Text as of 2026-10-04
14.04.010 - Adoption and filing.¶
California Building Codes adopted. California Code of Regulation Title 24 Parts 1 through 12 consisting of the: 2025 California Administrative Code; 2025 California Building Code with Appendix Chapters G, H, I, J, N, P, and Q; 2025 California Residential Code with Appendix Chapters BB, BF, BG, CH, CI, and CJ; 2025 California Electrical Code with Annexes A, C, I; 2025 California Mechanical Code with Appendix Chapters B, C, F, G, H; 2025 California Plumbing Code with Appendix Chapters A, D, G, H, I, J, M, R; 2025 California Energy Code; 2025 California Wildland-Urban Interface Code, 2025 California Historical Building Code; 2025 California Fire Code including Chapters 1,3, Section 503 of Chapter 5, Sections 1101 and 1104 of Chapter 11, Appendix Chapter 4 and Appendices B, C, D, E, F, G, H, I, K, M, N, O, and P; 2025 California Existing Building Code; 2025 California Green Building Standards Code; 2025 California Referenced Standards Code, and amendments from specific State of California State Agencies. One copy of all of the above publications shall be on file for public inspection and is hereby adopted with the same force and effect as though set out herein in full.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.015 - Section 1.1.1 of the California Building Code is amended to read as follows.¶
1.1.1 Title. These regulations shall be known as the California Building Code, may be cited as such and will be referred to herein as "this code." The California Building Code is Part 2 of thirteen parts of the official compilation and publication of the adoption, amendment and repeal of building regulations to the California Code of Regulations, Title 24, also referred to as the California Building Standards Code. This part incorporates by adoption the 2024 International Building Code of the International Code Council with necessary California amendments.
For the City of Pasadena, these regulations shall be known as the Pasadena Building Code. The provisions contained in the California Building Code of the (compiled) California Building Standards Code as defined in section 18910, Health and Safety Code, may be cited as such and are referred to hereafter as "these regulations" or "these building standards" or "this code". These regulations shall also be collectively known as the "California Building Code" as amended by the Pasadena Municipal Code.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.020 - Section 105.1.3 of Chapter 1 Division II of the 2025 California Building…¶
[A]105.1.3 Zoning Permits
A zoning permit may be required for items exempted from building permit requirements under Chapter 1 Division II Section 105.2. Exempted work shall not violate any provisions of this Code, Federal, State, Local laws, or regulations.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.025 - Section 903.2 of the 2025 California Building Code titled "Where required"…¶
903.2 Where required.
All new construction of buildings and structures shall be provided with an approved automatic fire sprinkler system.
Exception: The following types of construction may be exempt from this section when approved by the fire code official.
Detached private garages, utility sheds, and similar structures 500 square feet or less, accessory to a R-3 occupancy, provided no portion of the structure is located more than 150 feet (45,720 mm) from an approved fire department access road.
Detached Carports, detached gazebos, pergolas, and similar shade structures open on all sides constructed of non-combustible material 500 square feet or less, accessory to a R-3 occupancy.
Other similar structures as deemed appropriate by the fire code official.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.030 - Section 903.1 of the 2025 California Building Code is amended by adding…¶
903.1.2 Partial automatic fire sprinkler system prohibited.
Whenever an automatic fire sprinkler system is installed for any portion of any building or structure, an automatic fire sprinkler system shall be installed for the entire building or structure.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.035 - Section 903.2.18 of the 2025 California Building Code titled "Group U…¶
903.2.18 Group U detached and attached private garages, carports, and similar structures accessory to Group R-3 occupancies.
Carports with habitable space above and attached garages, accessory to Group R-3 occupancies, shall be protected by residential fire sprinklers in accordance with this section. When an automatic fire sprinkler system is required in accordance with sections 903.1.2 and 903.2, carports without habitable space above, detached garages, and similar attached and detached structures, accessory to R-3 occupancies, shall be protected by residential fire sprinklers in accordance with this section. Residential fire sprinklers shall be connected to, and installed in accordance with, an automatic residential fire sprinkler system that complies with Section R309 of the California Residential Code or with NFPA 13D. Fire sprinklers shall be residential sprinklers or quick-response sprinklers, designed to provide a minimum density of 0.05 gpm/ft2 (2.04 mm/min) over the area of the garage, carport, and/or similar structure, but not to exceed two sprinklers for hydraulic calculation purposes. Garage doors shall not be considered obstructions with respect to sprinkler placement.
(Ord. No. 7461, § 5, 11-10-2025)
14.05.040 - Section 903.3.5 of the 2025 California Building Code titled "Water…¶
903.3.5 Water supplies.
Water supplies for automatic sprinkler systems shall comply with this section and the standards referenced in Section 903.3.1. The potable water supply shall be protected against backflow in accordance with Health and Safety Code 13114.7. For connections to public waterworks systems, the water supply test used for design of fire protection systems shall be adjusted to account for seasonal and daily pressure fluctuations based on information from the water supply authority and as approved by the fire code official. Hydraulic calculations shall include a 10% safety margin.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.045 - Section 903.3.5.2 of the 2025 California Building Code titled "Residential…¶
903.3.5.2 Residential combination services.
A single combination water supply shall not be allowed for NFPA 13R systems.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.050 - Section 1505.1 of the 2025 California Building Code is amended to read as follows.¶
[BF] 1505.1 General.
Fire classification of roof assemblies shall be in accordance with Section 1505. The minimum fire classification of roof assemblies installed on buildings shall comply with Table 1505.1 based on type of construction of the building. Class A and B roof assemblies and roof coverings required to be listed by this section shall be tested in accordance with ASTM E108 or UL 790. In addition, fire-retardant-treated wood roof coverings shall be tested in accordance with ASTM D 2898. The minimum roof coverings installed on buildings shall comply with Table 1505.1 based on the type of construction of the building. All roof assemblies and roof coverings shall be of not less than Class B. No wood roof covering material shall be installed on any structure located in the very high, high and moderate fire hazard severity zones as identified by the Pasadena Fire Department.
Exception 1: Skylights and sloped glazing that comply with Chapter 24 or Section 2610. Installation of skylights of plastic material shall meet the requirements of the very high and high fire hazard severity zones.
Exception 2: In the moderate fire hazard severity zone, the fire code official may, upon a showing of good cause and necessity, approve the use of fire resistive wood as part of Class A listed assemblies, and may require additional mitigation as warranted, for the repair or maintenance of existing structures.
[BF] TABLE 1505.1—MINIMUM ROOF ASSEMBLY CLASSIFICATION FOR TYPES OF CONSTRUCTION a,
| IA | IB | IIA | IIB | IIIA | IIIB | IV | VA | VB |
|---|---|---|---|---|---|---|---|---|
| B | B | B | B c | B | B c | B | B | B c |
For SI: 1 foot = 304.8 mm, 1 square foot = 0.0929 m 2 .
a. Unless otherwise required in accordance with the California Wildland-Urban Interface Code or due to the location of the building within a fire district in accordance with Appendix D.
c. Buildings that are not more than two stories above grade plane and having not more than 6,000 square feet of projected roof area and where there is a minimum 10-foot fire-separation distance from the leading edge of the roof to a lot line on all sides of the building, except for street fronts or public ways and is not located in a fire hazard severity zones, shall be permitted to have roofs of No. 1 cedar or redwood shakes and No. 1 shingles constructed in accordance with Section 1505.7.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.055 - Section 1505.6 of the 2025 Edition of the California Building Code is amended to read as follows.¶
[BF] 1505.6 Fire-retardant-treated wood shingles and shakes.
Fire-retardant-treated wood shingles and wood shakes shall not be installed in the very high, high and moderate fire hazard severity zones. Fire-retardant-treated wood shakes and shingles are wood shakes and shingles complying with UBC Standard 15-3 or 15-4 which are impregnated by the full-cell vacuum-pressure process with fire-retardant chemicals, and which have been qualified by UBC Standard 15-2 for use on Class A, B roofs.
Fire-retardant-treated wood shakes and shingles shall comply with ICC-ES EG107 and with the weathering requirements contained in Health and Safety Code Section 13132.7(j). Each bundle shall bear labels from an ICC accredited quality control agency identifying their roof-covering classification and indicating their compliance with ICC-ES EGI07 and with the weathering requirements contained in Health and Safety Code Section 13132.7(j).
Health and Safety Code Section 13132.7(j). No wood roof covering materials shall be sold or applied in this state unless both of the following conditions are met:
(1) The materials have been approved and listed by the State Fire Marshal as complying with the requirements of this section.
(2) The materials have passed at least five years of the 10-year natural weathering test. The 10-year natural weathering test required by this subdivision shall be conducted in accordance with standard 15-2 of the 1994 Edition of the Uniform Building Code at a testing facility recognized by the State Fire Marshal.
Exception: In the moderate fire hazard severity zone, the fire code official may, upon a showing of good cause and necessity, approve the use of fire-resistive wood as part of Class A listed assemblies, and may require additional mitigation as warranted, for the repair or maintenance of existing structures.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.060 - Section 1507 of the 2025 California Building Code is amended by adding…¶
1507.1.3 Roof Sheathing.
When finish roofing material is removed to the existing open space sheathing, a minimum of 3/8-inch thick plywood sheathing shall be installed. The new sheathing shall comply with the requirements of the California Building Code. The sheathing shall be installed such that the edges align over rafters and individual spaced sheathing boards. The sheathing shall be attached to the existing spaced sheathing with 6d common nails at 6 inches (147mm) on center at supported edges and 6d common nails at 12 inches (294mm) on center at intermediate supports.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.065 - Sections 1613.8 and 1613.8.1 are added to Chapter 16 of the 2025 Edition of…¶
1613.8 Amendments to ASCE 7. The provisions of Section 1613.8 shall be permitted as an amendment to the relevant provisions of ASCE 7.
1613.8.1 Values for vertical combinations. Modify ASCE 7 Section 12.2.3.1 Exception 3 as follows:
- Detached one- and two-family dwellings up to two stories in height of light frame construction.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.070 - Section 1613.8.2 is added to Chapter 16 of the 2025 Edition of the…¶
1613.8.2 Wood diaphragms. Modify ASCE 7 Section 12.11.2.2.3 as follows:
12.11.2.2.3 Wood Diaphragms. The anchorage of concrete or masonry structural walls to wood diaphragms shall be in accordance with AWC SDPWS 4.1.5.1 and this section. Continuous ties required by this section shall be in addition to the diaphragm sheathing. Anchorage shall not be accomplished by use of toenails or nails subject to withdrawal, nor shall wood ledgers or framing be used in cross-grain bending or cross-grain tension. The diaphragm sheathing shall not be considered effective for providing the ties or struts required by this section.
For structures assigned to Seismic Design Category D, E or F, wood diaphragms supporting concrete or masonry walls shall comply with the following:
The spacing of continuous ties shall not exceed 40 feet. Added chords of diaphragms may be used to form subdiaphragms to transmit the anchorage forces to the main continuous crossties.
The maximum diaphragm shear used to determine the depth of the subdiaphragm shall not exceed 75% of the maximum diaphragm shear.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.075 - Section 1613.8.3 is added to Chapter 16 of the 2025 Edition of the…¶
1613.8.3 Structural separation. Modify ASCE 7 Section 12.12.3 Equation 12.12-1 as follows:
[Figure]
Where δDE1 and δDE2 are the Design Earthquake Displacements of the adjacent structures at their adjacent edges. Where a structure adjoins a property line not common to a public way, the structure shall be set back from the property line by at least the displacement δDE of that structure.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.080 - Section 1613.9 is added to Chapter 16 of the 2025 Edition of the California…¶
1613.9 Seismic design provisions for hillside buildings.
1613.9.1 Purpose. The purpose of this section is to establish minimum regulations for the design and construction of new buildings and additions to existing buildings when constructing such buildings on or into slopes steeper than one unit vertical in three units horizontal (33.3%). These regulations establish minimum standards for seismic force resistance to reduce the risk of injury or loss of life in the event of earthquakes.
1613.9.2 Scope. The provisions of this section shall apply to the design of the lateral-force-resisting system for hillside buildings at and below the base level diaphragm. The design of the lateral-force-resisting system above the base level diaphragm shall be in accordance with the provisions for seismic and wind design as required elsewhere in this division.
Exception: Non-habitable accessory buildings and decks not supporting or supported from the main building are exempt from these regulations.
1613.9.3 Definitions. For the purposes of this section certain terms are defined as follows:
BASE LEVEL DIAPHRAGM is the floor at, or closest to, the top of the highest level of the foundation.
DIAPHRAGM ANCHORS are assemblies that connect a diaphragm to the adjacent foundation at the uphill diaphragm edge.
DOWNHILL DIRECTION is the descending direction of the slope approximately perpendicular to the slope contours.
FOUNDATION is concrete or masonry which supports a building, including footings, stem walls, retaining walls, and grade beams.
FOUNDATION EXTENDING IN THE DOWNHILL DIRECTION is a foundation running downhill and approximately perpendicular to the uphill foundation.
HILLSIDE BUILDING is any building or portion thereof constructed on or into a slope steeper than one unit vertical in three units horizontal (33.3%). If only a portion of the building is supported on or into the slope, these regulations apply to the entire building.
PRIMARY ANCHORS are diaphragm anchors designed for and providing a direct connection as described in Sections 1613.9.5 and 1613.9.7.3 between the diaphragm and the uphill foundation.
SECONDARY ANCHORS are diaphragm anchors designed for and providing a redundant diaphragm to foundation connection, as described in Sections 1613.9.6 and. 1613.9.7.4.
UPHILL DIAPHRAGM EDGE is the edge of the diaphragm adjacent and closest to the highest ground level at the perimeter of the diaphragm.
UPHILL FOUNDATION is the foundation parallel and closest to the uphill diaphragm edge.
1613.9.4 Analysis and design.
1613.9.4.1 General. Every hillside building within the scope of this section shall be analyzed, designed, and constructed in accordance with the provisions of this division. When the code-prescribed wind design produces greater effects, the wind design shall govern, but detailing requirements and limitations prescribed in this and referenced sections shall be followed.
1613.9.4.2 Base level diaphragm-downhill direction. The following provisions shall apply to the seismic analysis and design of the connections for the base level diaphragm in the downhill direction.
1613.9.4.2.1 Base for lateral force design defined. For seismic forces acting in the downhill direction, the base of the building shall be the floor at or closest to the top of the highest level of the foundation.
1613.9.4.2.2 Base shear. In developing the base shear for seismic design, the response modification coefficient (R) shall not exceed 5 for bearing wall and building frame systems. The total base shear shall include the forces tributary to the base level diaphragm including forces from the base level diaphragm.
1613.9.5 Base shear resistance-primary anchors.
1613.9.5.1 General. The base shear in the downhill direction shall be resisted through primary anchors from diaphragm struts provided in the base level diaphragm to the foundation.
1613.9.5.2 Location of primary anchors. A primary anchor and diaphragm strut shall be provided in line with each foundation extending in the downhill direction. Primary anchors and diaphragm struts shall also be provided where interior vertical lateral-force-resisting elements occur above and in contact with the base level diaphragm. The spacing of primary anchors and diaphragm struts or collectors shall in no case exceed 30 feet (9144 mm).
1613.9.5.3 Design of primary anchors and diaphragm struts. Primary anchors and diaphragm struts shall be designed in accordance with the requirements of Section 1613.6.8.
1613.9.5.4 Limitations. The following lateral-force-resisting elements shall not be designed to resist seismic forces below the base level diaphragm in the downhill direction:
Wood structural panel wall sheathing,
Cement plaster and lath,
Gypsum wallboard, and
Tension only braced frames.
Braced frames designed in accordance with the requirements of Section 2206.2.1.2 may be used to transfer forces from the primary anchors and diaphragm struts to the foundation provided lateral forces do not induce flexural stresses in any member of the frame or in the diaphragm struts. Deflections of frames shall account for the variation in slope of diagonal members when the frame is not rectangular.
1613.9.6 Base shear resistance-secondary anchors.
1613.9.6.1 General. In addition to the primary anchors required by Section 1613.9.5 the base shear in the downhill direction shall be resisted through secondary anchors in the uphill foundation connected to diaphragm struts in the base level diaphragm.
Exception: Secondary anchors are not required where foundations extending in the downhill direction spaced at not more than 30 feet (9144 mm) on center extend up to and are directly connected to the base level diaphragm for at least 70% of the diaphragm depth.
1613.9.6.2 Secondary anchor capacity and spacing. Secondary anchors at the base level diaphragm shall be designed for a minimum force equal to the base shear, including forces tributary to the base level diaphragm, but not less than 600 pounds per lineal foot (8.76 kN/m) based on Allowable Stress Design (ASD) levels. The secondary anchors shall be uniformly distributed along the uphill diaphragm edge and shall be spaced a maximum of 4 feet (1219 mm) on center.
1613.9.6.3 Design. Secondary anchors and diaphragm struts shall be designed in accordance with Section 1613.9.8.
1613.9.7 Diaphragms below the base level-downhill direction. The following provisions shall apply to the lateral analysis and design of the connections for all diaphragms below the base level diaphragm in the downhill direction.
1613.9.7.1 Diaphragm defined. Every floor level below the base level diaphragm shall be designed as a diaphragm.
1613.9.7.2 Design force. Each diaphragm below the base level diaphragm shall be designed for all tributary loads at that level using a minimum seismic force factor not less than the base shear coefficient.
1613.9.7.3 Design force resistance-primary anchors. The design force described in Section 1613.9.7.2 shall be resisted through primary anchors from diaphragm struts provided in each diaphragm to the foundation. Primary anchors shall be provided and designed in accordance with the requirements and limitations of Section 1613.9.5.
1613.9.7.4 Design force resistance-secondary anchors.
1613.9.7.4.1 General. In addition to the primary anchors required in Section 1613.9.7.3 the design force in the downhill direction shall be resisted through secondary anchors in the uphill foundation connected to diaphragm struts in each diaphragm below the base level.
Exception: Secondary anchors are not required where foundations extending in the downhill direction, spaced at not more than 30 feet (9144 mm) on center, extend up to and are directly connected to each diaphragm below the base level for at least 70% of the diaphragm depth.
1613.9.7.4.2 Secondary anchor capacity. Secondary anchors at each diaphragm below the base level diaphragm shall be designed for a minimum force equal to the design force but not less than 300 pounds per lineal foot (4.38 kN/m) based on Allowable Stress Design (ASD) levels. The secondary anchors shall be uniformly distributed along the uphill diaphragm edge and shall be spaced a maximum of 4 feet (1219 mm) on center.
1613.9.7.4.3 Design. Secondary anchors and diaphragm struts shall be designed in accordance with Section 1613.9.8.
1613.9.8 Primary and secondary anchorage and diaphragm strut design. Primary and secondary anchors and diaphragm struts shall be designed in accordance with the following provisions:
Fasteners. All bolted fasteners used to develop connections to wood members shall be provided with square plate washers at all bolt heads and nuts. Washers shall be minimum 0.229 inch by 3 inches by 3 inches (5.82 mm by 76 mm by 76 mm) in size. Nuts shall be tightened to finger tight plus one half (1/2) wrench turn prior to covering the framing.
Fastening. The diaphragm to foundation anchorage shall not be accomplished by the use of toenailing, nails subject to withdrawal, or wood in cross-grain bending or cross-grain tension.
Size of Wood Members. Wood diaphragm struts collectors, and other wood members connected to primary anchors shall not be less than 3 inch (76 mm) nominal width. The effects of eccentricity on wood members shall be evaluated as required per Item 9.
Design. Primary and secondary anchorage, including diaphragm struts, splices, and collectors shall be designed for 125% of the tributary force.
Allowable Stress Increase. The one-third allowable stress increase permitted under Section 1605.2 shall not be taken when the working (allowable) stress design method is used.
Steel Element of Structural Wall Anchorage System. The strength design forces for steel elements of the structural wall anchorage system, with the exception of anchor bolts and reinforcing steel, shall be increased by 1.4 times the forces otherwise required.
Primary Anchors. The load path for primary anchors and diaphragm struts shall be fully developed into the diaphragm and into the foundation. The foundation must be shown to be adequate to resist the concentrated loads from the primary anchors.
Secondary Anchors. The load path for secondary anchors and diaphragm struts shall be fully developed in the diaphragm but need not be developed beyond the connection to the foundation.
Symmetry. All lateral force foundation anchorage and diaphragm strut connections shall be symmetrical. Eccentric connections may be permitted when demonstrated by calculation or tests that all components of force have been provided for in the structural analysis or tests.
Wood Ledgers. Wood ledgers shall not be used to resist cross-grain bending or cross-grain tension.
1613.9.9 Lateral-force-resisting elements normal to the downhill direction.
1613.9.9.1 General. In the direction normal to the downhill direction, lateral-force-resisting elements shall be designed in accordance with the requirements of this section.
1613.9.9.2 Base shear. In developing the base shear for seismic design, the response modification coefficient (R) shall not exceed 5 for bearing wall and building frame systems.
1613.9.9.3 Vertical distribution of seismic forces. For seismic forces acting normal to the downhill direction the distribution of seismic forces over the height of the building using Section 12.8.3 of ASCE 7 shall be determined using the height measured from the top of the lowest level of the building foundation.
1613.9.9.4 Drift limitations. The story drift below the base level diaphragm shall not exceed 0.007 times the story height at strength design force level. The total drift from the base level diaphragm to the top of the foundation shall not exceed 3/4 inch (19 mm). Where the story height or the height from the base level diaphragm to the top of the foundation varies because of a stepped footing or story offset, the height shall be measured from the average height of the top of the foundation. The story drift shall not be reduced by the effect of horizontal diaphragm stiffness.
1613.9.9.5 Distribution of lateral forces.
1613.9.9.5.1 General. The design lateral force shall be distributed to lateral-force-resisting elements of varying heights in accordance with the stiffness of each individual element.
1613.9.9.5.2 Wood structural panel sheathed walls. The stiffness of a stepped wood structural panel shear wall may be determined by dividing the wall into adjacent rectangular elements, subject to the same top of wall deflection. Deflections of shear walls may be estimated by AWC SDPWS Section 4.3.2. Sheathing and fastening requirements for the stiffest section shall be used for the entire wall. Each section of wall shall be anchored for shear and uplift at each step. The minimum horizontal length of a step shall be 8 feet (2438 mm) and the maximum vertical height of a step shall be 2 feet 8 inches (813 mm).
1613.9.9.5.3 Reinforced concrete or masonry shear walls. Reinforced concrete or masonry shear walls shall have forces distributed in proportion to the rigidity of each section of the wall.
1613.9.9.6 Limitations. The following lateral force-resisting-elements shall not be designed to resist lateral forces below the base level diaphragm in the direction normal to the downhill direction:
Cement plaster and lath,
Gypsum wallboard, and
Tension-only braced frames.
Braced frames designed in accordance with the requirements of Section 2202.2.1.2 of this Code may be designed as lateral-force-resisting elements in the direction normal to the downhill direction, provided lateral forces do not induce flexural stresses in any member of the frame. Deflections of frames shall account for the variation in slope of diagonal members when the frame is not rectangular.
1613.9.10 Specific design provisions.
1613.9.10.1 Footings and grade beams. All footings and grade beams shall comply with the following:
Grade beams shall extend at least 12 inches (305 mm) below the lowest adjacent grade and provide a minimum 24 inch (610 mm) distance horizontally from the bottom outside face of the grade beam to the face of the descending slope.
Continuous footings shall be reinforced with at least two No. 4 reinforcing bars at the top and two No. 4 reinforcing bars at the bottom.
All main footing and grade beam reinforcement steel shall be bent into the intersecting footing and fully developed around each corner and intersection.
All concrete stem walls shall extend from the foundation and reinforced as required for concrete or masonry walls.
1613.9.10.2 Protection against decay and termites. All wood to earth separation shall comply with the following:
- Where a footing or grade beam extends across a descending slope, the stem wall, grade beam, or footing shall extend up to a minimum 18 inches (457 mm) above the highest adjacent grade.
Exception: At paved garage and doorway entrances to the building, the stem wall need only extend to the finished concrete slab, provided the wood framing is protected with a moisture proof barrier.
- Wood ledgers supporting a vertical load of more than 100 pounds per lineal foot (1.46 kN/m) based on Allowable Stress Design (ASD) levels and located within 48 inches (1219 mm) of adjacent grade are prohibited. Galvanized steel ledgers and anchor bolts, with or without wood nailers, or treated or decay resistant sill plates supported on a concrete or masonry seat, may be used.
1613.9.10.3 Sill plates. All sill plates and anchorage shall comply with the following:
All wood framed walls, including nonbearing walls, when resting on a footing, foundation, or grade beam stem wall, shall be supported on wood sill plates bearing on a level surface.
Power-driven fasteners shall not be used to anchor sill plates except at interior nonbearing walls not designed as shear walls.
1613.9.10.4 Column base plate anchorage. The base of isolated wood posts (not framed into a stud wall) supporting a vertical load of 4,000 pounds (17.8 kN) based on Allowable Stress Design (ASD) levels or more and the base plate for a steel column shall comply with the following:
When the post or column is supported on a pedestal extending above the top of a footing or grade beam, the pedestal shall be designed and reinforced as required for concrete or masonry columns. The pedestal shall be reinforced with a minimum of four No. 4 bars extending to the bottom of the footing or grade beam. The top of exterior pedestals shall be sloped for positive drainage.
The base plate anchor bolts or the embedded portion of the post base, and the vertical reinforcing bars for the pedestal, shall be confined with two No. 4 or three No. 3 ties within the top 5 inches (127 mm) of the concrete or masonry pedestal. The base plate anchor bolts shall be embedded a minimum of 20 bolt diameters into the concrete or masonry pedestal. The base plate anchor bolts and post bases shall be galvanized and each anchor bolt shall have at least 2 galvanized nuts above the base plate.
1613.9.10.5 Steel beam to column supports. All steel beam to column supports shall be positively braced in each direction. Steel beams shall have stiffener plates installed on each side of the beam web at the column. The stiffener plates shall be welded to each beam flange and the beam web. Each brace connection or structural member shall consist of at least two ⅝ inch (15.9 mm) diameter machine bolts.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.085 - Section 1613.10 is added to Chapter 16 of the 2025 Edition of the…¶
1613.10 Suspended ceilings. Minimum design and installation standards for suspended ceilings shall be determined in accordance with the requirements of Section 2506.2.1 of this Code and this section.
1613.10.1 Scope. This part contains special requirements for suspended ceilings and lighting systems. Provisions of Section 13.5.6 of ASCE 7 shall apply except as modified herein.
1613.10.2 General. The suspended ceilings and lighting systems shall be limited to 6 feet (1828 mm) below the structural deck unless the lateral bracing is designed by a licensed engineer or architect.
1613.10.3 Sprinkler heads. All sprinkler heads (drops) except fire-resistance-rated floor/ceiling or roof/ceiling assemblies, shall be designed to allow for free movement of the sprinkler pipes with oversize rings, sleeves or adaptors through the ceiling tile. Sprinkler heads and other penetrations shall have a 2 inch (50mm) oversize ring, sleeve, or adapter through the ceiling tile to allow for free movement of at least 1 inch (25mm) in all horizontal directions. Alternatively, a swing joint that can accommodate 1 inch (25 mm) of ceiling movement in all horizontal directions is permitted to be provided at the top of the sprinkler head extension.
Sprinkler heads penetrating fire-resistance-rated floor/ceiling or roof/ceiling assemblies shall comply with Section 714 of this Code.
1613.10.4 Special requirements for means of egress. Suspended ceiling assemblies located along means of egress serving an occupant load of 30 or more and at lobbies accessory to Group A Occupancies shall comply with the following provisions.
1613.10.4.1 General. Ceiling suspension systems shall be connected and braced with vertical hangers attached directly to the structural deck along the means of egress serving an occupant load of 30 or more and at lobbies accessory to Group A Occupancies. Spacing of vertical hangers shall not exceed 2 feet (610 mm) on center along the entire length of the suspended ceiling assembly located along the means of egress or at the lobby.
1613.10.4.2 Assembly device. All lay-in panels shall be secured to the suspension ceiling assembly with two hold-down clips minimum for each tile within a 4-foot (1219 mm) radius of the exit lights and exit signs.
1613.10.4.3 Emergency systems. Independent supports and braces shall be provided for light fixtures required for exit illumination. Power supply for exit illumination shall comply with the requirements of Section 1008.3 of this Code.
1613.10.4.4 Supports for appendage. Separate support from the structural deck shall be provided for all appendages such as light fixtures, air diffusers, exit signs, and similar elements.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.090 - Section 1704.6 of the 2025 Edition of the California Building Code is amended to read as follows.¶
1704.6 Structural Observations.
Where required by the provisions of Section 1704.6.1, the owner or the owner's authorized agent shall employ a registered design professional to perform structural observations. The structural observer shall visually observe representative locations of structural systems, details and load paths for general conformance to the approved construction documents. Structural observation does not include or waive the responsibility for the inspections in Section 110 or the special inspections in Section 1705 or other sections of this code. Prior to the commencement of observations, the structural observer shall submit to the building official a written statement identifying the frequency and extent of structural observations. At the conclusion of the work included in the permit, the structural observer shall submit to the building official a written statement that the site visits have been made and identify any reported deficiencies that, to the best of the structural observer's knowledge, have not been resolved.
The structural observer shall be one of the following individuals:
The registered design professional responsible for the structural design, or
A registered design professional designated by the registered design professional responsible for the structural design.
The owner or owner's authorized agent shall coordinate and call a preconstruction meeting between the structural observer, contractors, affected subcontractors and special inspectors. The structural observer shall preside over the meeting. The purpose of the meeting shall be to identify the major structural elements and connections that affect the vertical and lateral load resisting systems of the structure and to review scheduling of the required observations. A record of the meeting shall be included in the report submitted to the building official.
Observed deficiencies shall be reported in writing to the owner or owner's authorized agent, special inspector, contractor and the building official. Upon the form prescribed by the building official, the structural observer shall submit to the building official a written statement at each significant construction stage stating that the site visits have been made and identifying any reported deficiencies which, to the best of the structural observer's knowledge, have not been resolved. A final report by the structural observer which states that all observed deficiencies have been resolved is required before acceptance of the work by the building official.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.095 - Section 1704.6.1 of the 2025 Edition of the California Building Code is…¶
1704.6.1 Structural observations for structures.
Structural observations shall be provided for those structures where one or more of the following conditions exist:
The structure is classified as Risk Category III or IV.
The structure is a high-rise building.
The structure is assigned to Seismic Design Category E, and is greater than two stories above grade plane.
Such observation is required by the registered design professional responsible for the structural design.
Such observation is specifically required by the building official.
A lateral design is required for the structure or portion thereof.
Exception: One-story wood framed Group R-3 and Group U Occupancies less than 2,000 square feet in area, provided the adjacent grade is not steeper than 1 unit vertical in 10 units horizontal (10% sloped), assigned to Seismic Design Category D.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.100 - Section 1705.3 of the 2025 Edition of the California Building Code is amended to read as follows.¶
1705.3 Concrete construction.
Special inspections and tests of concrete construction shall be performed in accordance with this section and Table 1705.3.
Exceptions: Special inspections and tests shall not be required for: [OSHPD 1R, 2 & 5] Exceptions 1 through 4 are not permitted by OSHPD.
Isolated spread concrete footings of buildings three stories or less above grade plane that are fully supported on earth or rock, where the structural design of the footing is based on a specified compressive strength, f′ c , no greater than 2,500 pounds per square inch (psi) (17.2 MPa) regardless of the compressive strength specified in the construction documents or used in the footing construction.
Continuous concrete footings supporting walls of buildings three stories or less above grade plane that are fully supported on earth or rock where:
2.1.
The footings support walls of light-frame construction.
2.2.
The footings are designed in accordance with Table 1809.7.
2.3.
The structural design of the footing is based on a specified compressive strength, f′ c , not more than 2,500 pounds per square inch (psi) (17.2 MPa), regardless of the compressive strength specified in the approved construction documents or used in the footing construction.
Nonstructural concrete slabs supported directly on the ground, including prestressed slabs on grade, where the effective prestress in the concrete is less than 150 psi (1.03 MPa).
Reserved.
Concrete patios, driveways and sidewalks, on grade.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.105 - Section 1807.1.4 of the 2025 Edition of the California Building Code is…¶
1807.1.4 Permanent wood foundation systems
[OSHPD 1R, 2 & 5] Not permitted by OSHPD. Permanent wood foundation systems shall be designed and installed in accordance with AWC PWF. Lumber and plywood shall be preservative treated in accordance with AWPA U1 (Commodity Specification A, Special Requirement 4.2) and shall be identified in accordance with Section 2303.1.9.1. Permanent wood foundation systems shall not be used for structures assigned to Seismic Design Category D, E or F.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.110 - Section 1807.1.6 of the 2025 Edition of the California Building Code is…¶
1807.1.6 Prescriptive design of concrete and masonry foundation walls.
[OSHPD 1R, 2 & 5] Not permitted by OSHPD. Concrete and masonry foundation walls that are laterally supported at the top and bottom shall be permitted to be designed and constructed in accordance with this section. Prescriptive design of foundation walls shall not be used for structures assigned to Seismic Design Category D, E or F.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.115 - Section 1807.2 of the 2025 Edition of the California Building Code is…¶
1807.2 Retaining walls.
Retaining walls shall be designed in accordance with Section 1807.2.1 through 1807.2.4. Retaining walls assigned to Seismic Design Category D, E or F shall not be partially or wholly constructed of wood.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.120 - Section 1807.3.1 of the 2025 Edition of the California Building Code is…¶
1807.3.1 Limitations. The design procedures outlined in this section are subject to the following limitations:
The frictional resistance for structural walls and slabs on silts and clays shall be limited to one-half of the normal force imposed on the soil by the weight of the footing or slab.
Posts embedded in earth shall not be used to provide lateral support for structural or nonstructural materials such as plaster, masonry or concrete unless bracing is provided that develops the limited deflection required.
Wood poles shall be treated in accordance with AWPA U1 for sawn timber posts (Commodity Specification A, Use Category 4B) and for round timber posts (Commodity Specification B, Use Category 4B). Wood poles and posts embedded in direct contact with soil shall not be used for structures assigned to Seismic Design Category D, E or F.
Exception: Wood poles and posts embedded in direct contact with soil may be used to support nonhabitable, nonoccupiable structures such as fences when approved by the building official.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.125 - Section 1809.3 of the 2025 Edition of the California Building Code is amended to read as follows.¶
1809.3 Stepped footings. The top surface of footings shall be level. The bottom surface of footings shall be permitted to have a slope not exceeding one unit vertical in 10 units horizontal (10-percent slope). Footings shall be stepped where it is necessary to change the elevation of the top surface of the footing or where the surface of the ground slopes more than one unit vertical in 10 units horizontal (10-percent slope).
[OSHPD 1R, 2 & 5] Individual steps in continuous footings shall not exceed 18 inches (457 mm) in height and the slope of a series of such steps shall not exceed 1 unit vertical to 2 units horizontal (50-percent slope) unless otherwise recommended by a geotechnical report. The steps shall be detailed on the drawings. The local effects due to the discontinuity of the steps shall be considered in the design of the foundation.
For structures assigned to Seismic Design Category D, E or F, the stepping requirement shall also apply to the top surface of continuous footings supporting walls. Footings shall be reinforced with four No. 4 deformed reinforcing bars. Two bars shall be placed at the top and bottom of the footings as shown in Figure 1809.3.
[Figure: FIGURE 1809.3 STEPPED FOOTING]
FIGURE 1809.3 STEPPED FOOTING
(Ord. No. 7461, § 5, 11-10-2025)
14.04.130 - Section 1809.7 and Table 1809.7 of the 2025 Edition of the California…¶
1809.7 Prescriptive footings for light-frame construction.
[OSHPD 1R, 2 & 5] Not permitted by OSHPD. Where a specific design is not provided, concrete or masonry-unit footings supporting walls of light-frame construction shall be permitted to be designed in accordance with Table 1809.7. Light-frame construction using prescriptive footings in Table 1809.7 shall not exceed one story above grade plane for structures assigned to Seismic Design Category D, E or F.
TABLE 1809.7 PRESCRIPTIVE FOOTINGS SUPPORTING WALLS OF LIGHT-FRAME CONSTRUCTION a, b, c, d, e
| NUMBER OF FLOORS SUPPORTED BY THE FOOTING f | WIDTH OF FOOTING (inches) | THICKNESS OF FOOTING (inches) |
|---|---|---|
| 1 | 12 | 6 |
| 2 | 15 | 6 |
| 3 | 18 | 8 |
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm
a. Depth of footings shall be in accordance with Section 1809.4.
b. The ground under the floor shall be permitted to be excavated to the elevation of the top of the footing.
c. Not adopted.
d. See Section 1905 for additional requirements for concrete footings of structures assigned to Seismic Design Category C, D, E or F.
e. For thickness of foundation walls, see Section 1807.1.6.
f. Footings shall be permitted to support a roof addition to the stipulated number of floors. Footings supporting roof only shall be as required for supporting one floor.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.135 - Section 1809.12 of the 2025 Edition of the California Building Code is amended to read as follows.¶
1809.12 Timber footings.
[OSHPD 1R, 2 & 5] Not permitted by OSHPD. Timber footings shall be permitted for buildings of Type V construction and as otherwise approved by the Building Official. Such footings shall be treated in accordance with AWPA U1 (Commodity Specification A, Use Category 4B). Treated timbers are not required where placed entirely below permanent water level, or where used as capping for wood piles that project above the water level over submerged or marsh lands. The compressive stresses perpendicular to grain in untreated timber footings supported on treated piles shall not exceed 70 percent of the allowable stresses for the species and grade of timber as specified in the ANSI/AWC NDS. Timber footings shall not be used in structures assigned to Seismic Design Category D, E or F.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.140 - Section 1810.3.2.4 of the 2025 Edition of the California Building Code is…¶
1810.3.2.4 Timber.
[OSHPD 1R, 2 & 5] Not permitted by OSHPD. Timber deep foundation elements shall be designed as piles or poles in accordance with ANSI/AWC NDS. Round timber elements shall conform to ASTM D 25. Sawn timber elements shall conform to DOC PS-20. Timber deep foundation elements shall not be used in structures assigned to Seismic Design Category D, E or F.
1810.3.2.4.1 Preservative treatment.
Timber deep foundation elements used to support permanent structures shall be treated in accordance with this section unless it is established that the tops of the untreated timber elements will be below the lowest ground-water level assumed to exist during the life of the structure. Preservative and minimum final retention shall be in accordance with AWPA U1 (Commodity Specification E, Use Category 4C) for round timber elements and AWPA U1 (Commodity Specification A, Use Category 4B) for sawn timber elements. Preservative-treated timber elements shall be subject to a quality control program administered by an approved agency. Element cutoffs shall be treated in accordance with AWPA M4.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.145 - Section 1905.6.2 of the 2025 Edition of the California Building Code is…¶
1905.6.2 Seismic design categories C, D, E, and F.
Structural plain concrete basement, foundation or other walls below the base as defined in ASCE/SEI 7 are permitted in detached one-and-two-family dwellings three stories or less in height constructed with stud-bearing walls. In dwellings assigned to Seismic Design Category D or E, the height of the wall shall not exceed 8 feet (2438 mm), the thickness shall be not less than 71/2 inches (190 mm), and the wall shall retain not more than 4 feet (1219 mm) of unbalanced fill. Walls shall have reinforcement in accordance with Section 14.6.1 of ACI 318.
Isolated footings of plain concrete supporting pedestals or columns are permitted, provided that the projection of the footing beyond the face of the supported member does not exceed the footing thickness.
Exception: In detached one-and-two-family dwellings three stories or less in height, the projection of the footing beyond the face of the supported member is permitted to exceed the footing thickness.
- Plain concrete footings supporting wall are permitted, provided that the footings have not fewer than two continuous longitudinal reinforcing bars. Bars shall not be smaller than No. 4 and shall have a total area of not less than 0.002 times the gross cross-sectional area of the footing. For footings that exceed 8 inches (203 mm) in thickness, not fewer than one bar shall be provided at the top and bottom of the footing. Continuity of reinforcement shall be provided at corners and intersections.
Exceptions:
a. Where assigned to Seismic Design Category C, detached one-and-two-family dwellings three stories or less in height constructed with stud-bearing walls are permitted to have plain concrete footings without longitudinal reinforcement.
b. For foundation systems consisting of a plain concrete footing and a plain concrete stemwall, not fewer than one bar shall be provided at the top of the stemwall and at the bottom of the footing.,
c. Footings cast monolithically with a slab-on-grade shall have not fewer than one No. 4 bar at the top and bottom of the footing or one No. 5 bar or two No. 4 bars in the middle third of the footing depth.
Structures assigned to Seismic Design Category C, D, E, or F shall not have elements of structural plain concrete except where concrete used for fill with a minimum cement content of two (2) sacks of Portland cement or cementitious material per cubic yard.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.150 - Subsections 1905.8 through 1905.10 are added to Chapter 19 of the 2025…¶
1905.8 ACI 318, Section 18.7.5. Modify ACI 318, Section 18.7.5, by adding Section 18.7.5.8 and 18.7.5.9 as follows:
18.7.5.8 Where the calculated point of contraflexure is not within the middle half of the member clear height, provide transverse reinforcement as specified in ACI 318 Sections 18.7.5.1, Items (a) through (c), over the full height of the member.
18.7.5.9 At any section where the design strength, φP n , of the column is less than the sum of the shears V e computed in accordance with ACI 318 Sections 18.7.6.1 and 18.6.5.1 for all the beams framing into the column above the level under consideration, transverse reinforcement as specified in ACI 318 Sections 18.7.5.1 through 18.7.5.3 shall be provided. For beams framing into opposite sides of the column, the moment components are permitted to be assumed to be of opposite sign. For the determination of the design strength, φP n , of the column, these moments are permitted to be assumed to result from the deformation of the frame in any one principal axis.
1905.9 ACI 318, Section 18.10.4. Modify ACI 318, Section 18.10.4, by adding Section 18.10.4.7 as follows:
18.10.4.7 Walls and portions of walls with P u > 0.35P o shall not be considered to contribute to the calculated shear strength of the structure for resisting earthquake-induced forces. Such walls shall conform to the requirements of ACI 318 Section 18.14.
1905.10 ACI318, Section 18.12.6. Modify ACI 318, by adding Section 18.12.6.2 as follows:
18.12.6.2 Collector and boundary elements in topping slabs placed over precast floor and roof elements shall not be less than 3 inches (76 mm) or 6 d b in thickness, where d b is the diameter of the largest reinforcement in the topping slab.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.155 - Section 2304.10.2 of the 2025 Edition of the California Building Code is…¶
2304.10.2 Fastener requirements. Connections for wood members shall be designed in accordance with the appropriate methodology in Section 2302.1. The number and size of fasteners connecting wood members shall not be less than that set forth in Table 2304.10.2. Staple fasteners in Table 2304.10.2 shall not be used to resist or transfer seismic forces in structures assigned to Seismic Design Category D, E or F.
Exception: Staples may be used to resist or transfer seismic forces when the allowable shear values are substantiated by cyclic testing and approved by the building official.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.160 - Section 2304.10.3.1 of the 2025 Edition of the California Building Code is…¶
2304.10.3.1 Quality of Nails. In Seismic Design Category D, E or F, mechanically driven nails used in wood structural panel shear walls shall meet the same dimensions as that required for hand-driven nails, including diameter, minimum length and minimum head diameter. Clipped head or box nails are not permitted in new construction. The allowable design value for clipped head nails in existing construction may be taken at no more than the nail-head-area ratio of that of the same size hand-driven nails.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.165 - Section 2304.12.2.8 of the 2025 Edition of the California Building Code is…¶
2304.12.2.8 Wood used in retaining walls and cribs. Wood installed in retaining or crib walls shall be preservative treated in accordance with AWPA U1 for soil and fresh water use. Wood shall not be used in retaining or crib walls for structures assigned to Seismic Design Category D, E or F.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.170 - Section 2305.4 is added to the 2025 Edition of the California Building Code to read as follows.¶
2305.4 Hold-down connectors. In Seismic Design Category D, E or F, hold-down connectors shall be designed to resist shear wall overturning moments using approved cyclic load values or 75 percent of the allowable seismic load values that do not consider cyclic loading of the product. Connector bolts into wood framing shall require steel plate washers on the post on the opposite side of the anchorage device. Plate size shall be a minimum of 0.229 inch by 3 inches by 3 inches (5.82 mm by 76 mm by 76 mm) in size. Hold-down connectors shall be tightened to finger tight plus one half (1/2) wrench turn just prior to covering the wall framing.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.175 - Section 2306.2 is added to the 2025 Edition of the California Building Code to read as follows.¶
2306.2 Wood-frame diaphragms. Wood-frame diaphragms shall be designed and constructed in accordance with AWC SDPWS. Where panels are fastened to framing members with staples, requirements and limitations of AWC SDPWS shall be met and the allowable shear values set forth in Table 2306.2(1) or 2306.2(2) shall only be permitted for structures assigned to Seismic Design Category A, B, or C.
Exception: Allowable shear values where panels are fastened to framing members with staples may be used if such values are substantiated by cyclic testing and approved by the building official.
The allowable shear values in Tables 2306.2(1) and 2306.2(2) are permitted to be increased 40 percent for wind design.
Wood structural panels used to resist seismic diaphragm forces in structures assigned to Seismic Design Category D, E or F shall be applied directly to the framing members.
Exception: Wood structural panels are permitted to be fastened over solid lumber planking or laminated decking, provided the panel joints and lumber planking or laminated decking joints do not coincide.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.180 - Section 2306.3 is added to the 2025 Edition of the California Building Code to read as follows.¶
2306.3 Wood-frame shear walls. Wood-frame shear walls shall be designed and constructed in accordance with AWC SDPWS. For structures assigned to Seismic Design Category D, E, or F, application of Table 4.3A of ANSI/AWC SDPWS shall include the following:
Wood structural panel thickness for shear walls shall not be less than 3/8 inch thick and studs shall not be spaced at more than 16 inches on center.
The maximum nominal unit shear capacities for 3/8 inch wood structural panels resisting seismic forces in structures assigned to Seismic Design Category D, E or F is 400 pounds per linear foot (plf).
Exception: Other nominal unit shear capacities may be permitted if such values are substantiated by cyclic testing and approved by the building official.
- Nails shall be placed not less than 1/2 inch in from the panel edges and not less than 3/8 inch from the edge of the connecting members for shear greater than 350 plf using ASD or 500 plf using LRFD. Nails shall be placed not less than 3/8 inch from panel edges and not less than 1/4 inch from the edge of the connecting members for shears of 350 plf or less using ASD or 500 plf or less using LRFD.
For structures assigned to Seismic Design Category D, E or F, application of Table 4.3B of ANSI/AWC SDPWS shall not be allowed.
For structures assigned to Seismic Design Category D, E or F, application of Table 4.3C of ANSI/AWC SDPWS shall not be used below the top level in a multi-level building.
Where panels are fastened to framing members with staples, requirements and limitations of AWC SDPWS shall be met and the allowable shear values set forth in Table 2306.3(1), 2306.3(2) or 2306.3(3) shall only be permitted for structures assigned to Seismic Design Category A, B, or C.
Exception: Allowable shear values where panels are fastened to framing members with staples may be used if such values are substantiated by cyclic testing and approved by the building official.
The allowable shear values in Tables 2306.3(1) and 2306.3(2) are permitted to be increased 40 percent for wind design. Panels complying with ANSI/APA PRP-210 shall be permitted to use design values for Plywood Siding in the AWC SDPWS.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.185 - Section 2307.2 is added to the 2025 Edition of the California Building Code to read as follows.¶
2307.2 Wood-frame shear walls. Wood-frame shear walls shall be designed and constructed in accordance with Section 2306.3 as applicable.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.190 - Table 2308.10.1 is added to the 2025 Edition of the California Building Code to read as follows.¶
[Figure]
(Ord. No. 7461, § 5, 11-10-2025)
4.04.195 - Sections 2308.10.5.1 and 2308.10.5.2 and Figures 2308.10.5.1 and 2308.10.5.2…¶
2308.10.5.1 Alternate braced wall (ABW). An ABW shall be constructed in accordance with this section and Figure 2308.10.5.1. In one-story buildings, each panel shall have a length of not less than 2 feet 8 inches (813 mm) and a height of not more than 10 feet (3048 mm). Each panel shall be sheathed on one face with 3/8-inch (3.2 mm) minimum-thickness wood structural panel sheathing nailed with 8d common or galvanized box nails in accordance with Table 2304.10.2 and blocked at wood structural panel edges. For structures assigned to Seismic Design Category D or E, each panel shall be sheathed on one face with 15/32-inch-minimum-thickness (11.9 mm) wood structural panel sheathing nailed with 8d common nails spaced 3 inches on panel edges, 3 inches at intermediate supports. Two anchor bolts installed in accordance with Section 2308.7.1 shall be provided in each panel. Anchor bolts shall be placed at each panel outside quarter points. Each panel end stud shall have a hold-down device fastened to the foundation, capable of providing an approved uplift capacity of not less than 1,800 pounds (8006 N). The hold-down device shall be installed in accordance with the manufacturer's recommendations. The ABW shall be supported directly on a foundation or on floor framing supported directly on a foundation that is continuous across the entire length of the braced wall line. This foundation shall be reinforced with not less than one No. 4 bar top and bottom. Where the continuous foundation is required to have a depth greater than 12 inches (305 mm), a minimum 12-inch by 12-inch (305 mm by 305 mm) continuous footing is permitted at door openings in the braced wall line. This continuous footing shall be reinforced with not less than one No. 4 bar top and bottom. This reinforcement shall be lapped 15 inches (381 mm) with the reinforcement required in the continuous foundation located directly under the braced wall line.
Where the ABW is installed at the first story of two-story buildings, the wood structural panel sheathing shall be provided on both faces, three anchor bolts shall be placed at one-quarter points and tie-down device uplift capacity shall be not less than 3,000 pounds (13 344 N).
[Figure]
2308.10.5.2 Portal frame with hold-downs (PFH). A PFH shall be constructed in accordance with this section and Figure 2308.10.5.2. The adjacent door or window opening shall have a full-length header.
In one-story buildings, each panel shall have a length of not less than 16 inches (406 mm) and a height of not more than 10 feet (3048 mm). Each panel shall be sheathed on one face with a single layer of 3/8-inch (9.5 mm) minimum-thickness wood structural panel sheathing nailed with 8d common or galvanized box nails in accordance with Figure 2308.10.5.2. For structures assigned to Seismic Design Category D or E. each panel shall be sheathed on one face with 15/32-inch-minimum-thickness (11.9 mm) wood structural panel sheathing nailed with 8d common nails spaced 3 inches on panel edges, 3 inches at intermediate supports and in accordance with Figure 2308.10.5.2. The wood structural panel sheathing shall extend up over the solid sawn or glued-laminated header and shall be nailed in accordance with Figure 2308.10.5.2. A built-up header consisting of at least two 2-inch by 12-inch (51 mm by 305 mm) boards, fastened in accordance with Item 24 of Table 2304.10.2 shall be permitted to be used. A spacer, if used, shall be placed on the side of the built-up beam opposite the wood structural panel sheathing. The header shall extend between the inside faces of the first full-length outer studs of each panel. The clear span of the header between the inner studs of each panel shall be not less than 6 feet (1829 mm) and not more than 18 feet (5486 mm) in length. A strap with an uplift capacity of not less than 1,000 pounds (4,400 N) shall fasten the header to the inner studs opposite the sheathing. One anchor bolt not less than ⅝ inch (15.9 mm) diameter and installed in accordance with Section 2308.7.1 shall be provided in the center of each sill plate. The studs at each end of the panel shall have a hold-down device fastened to the foundation with an uplift capacity of not less than 3,500 pounds (15 570 N).
Where a panel is located on one side of the opening, the header shall extend between the inside face of the first full-length stud of the panel and the bearing studs at the other end of the opening. A strap with an uplift capacity of not less than 1,000 pounds (4400 N) shall fasten the header to the bearing studs. The bearing studs shall also have a hold-down device fastened to the foundation with an uplift capacity of not less than 1,000 pounds (4400 N). The hold-down devices shall be an embedded strap type, installed in accordance with the manufacturer's recommendations. The PFH panels shall be supported directly on a foundation that is continuous across the entire length of the braced wall line. This foundation shall be reinforced with not less than one No. 4 bar top and bottom. Where the continuous foundation is required to have a depth greater than 12 inches (305 mm), a minimum 12-inch by 12-inch (305 mm by 305 mm) continuous footing is permitted at door openings in the braced wall line. This continuous footing shall be reinforced with not less than one No. 4 bar top and bottom. This reinforcement shall be lapped not less than 15 inches (381 mm) with the reinforcement required in the continuous foundation located directly under the braced wall line.
Where a PFH is installed at the first story of two-story buildings, each panel shall have a length of not less than 24 inches (610 mm).
[Figure]
(Ord. No. 7461, § 5, 11-10-2025)
14.04.200 - Section 2308.10.8.1 is added to the 2025 Edition of the California Building…¶
2308.10.8.1 Foundation requirements. Braced wall lines shall be supported by continuous foundations.
Exception: For structures with a maximum plan dimension not more than 50 feet (15 240 mm), continuous foundations are required at exterior walls only for structures assigned to Seismic Design Category A, B, or C.
For structures in Seismic Design Categories D and E, exterior braced wall panels shall be in the same plane vertically with the foundation or the portion of the structure containing the offset shall be designed in accordance with accepted engineering practice and Section 2308.3.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.205 - Section 2308.10.9 of the 2025 Edition of the California Building Code is…¶
2308.10.9 Attachment of sheathing. Fastening of braced wall panel sheathing shall not be less than that prescribed in Tables 2308.10.1 or 2304.10.2. Wall sheathing shall not be attached to framing members by adhesives. Staple fasteners in Table 2304.10.2 shall not be used to resist or transfer seismic forces in structures assigned to Seismic Design Category D, E or F.
Exception: Staples may be used to resist or transfer seismic forces when the allowable shear values are substantiated by cyclic testing and approved by the building official.
All braced wall panels shall extend to the roof sheathing and shall be attached to parallel roof rafters or blocking above with framing clips (18 gauge minimum) spaced at maximum 24 inches (6096 mm) on center with four 8d nails per leg (total eight 8d nails per clip minimum). Braced wall panels shall be laterally braced at each top corner and at intervals not to exceed 24 inches (6096 mm) intervals along the top plate of discontinuous vertical framing.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.210 - Section 3103.1.3 of the 2025 Edition of the California Building Code is…¶
3103.1.3 Permit required.
Temporary structures that cover an area greater than 120 square feet (11.16 m 2 ), including connecting areas or spaces with a common means of egress or entrance that are used or intended to be used for the gathering together of 10 or more persons, shall not be erected, operated or maintained for any purpose without obtaining a permit from the building official.
Temporary tent and membrane structures for special events. A permit is required to operate an air-supported temporary membrane structure, a temporary special event tent having an area in excess of 400 square feet (37 m 2 ). The aggregate area of multiple tents placed side by side without a fire break clearance of not less than 12 feet (3658 mm) shall not exceed 400 square feet (37 m 2 ) total. A minimum clearance of 12 feet (3658 mm) to structures and other tents shall be provided.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.215 - Section 3109.1.1 to the 2025 Edition of the California Building Code is added to read as follows.¶
In addition to the requirements of Section 3109 in the California Building Code, a swimming pool, pool, spa or any body of water over 18 inches deep shall have an enclosure consisting of a fence, wall, portions of a building or other approved durable material, that isolates all bodies of water from the private building or structure. The enclosure shall be installed around the perimeter of the bodies of water, or at the perimeter of the property.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.220 - Exception 6 of Section 3114.1 to Chapter 31 of the 2025 Edition of the…¶
- Single-unit stand-alone intermodal shipping containers used as temporary storage or construction trailer on active construction sites. Construction support facilities for uses and activities not directly associated with the actual processes of construction, including but not limited to, offices, meeting rooms, plan rooms, other administrative or support functions shall not be exempt from Section 3114.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.225 - Section J103.2 of the 2025 Edition of the California Building Code is amended to read as follows.¶
- An excavation that does not exceed 50 cubic yards (38.3 m 3 ) and complies with (a) or (b) as follows:
(a) Is less than 2 feet (0.6 m) in depth.
(b) Does not create a cut slope greater than 5 feet (1.5 m) measured vertically upward from the cut surface to the surface of the natural grade and is not steeper than 2 units horizontal to 1 unit vertical (50 percent slope).
(Ord. No. 7461, § 5, 11-10-2025)
14.04.300 - Section R101.1 of the California Residential Code is amended to read as follows.¶
R101.1 Title. For the city of Pasadena, these regulations shall be known as the Pasadena Residential Code. The provisions contained in the California Residential Code of the (compiled) California Building Standards Code as defined in section 18910, Health and Safety Code, may be cited as such and are referred to hereafter as 'these regulations' or 'these building standards' or 'this code.' These regulations shall also be collectively known as the 'California Residential Code' as amended by the Pasadena Municipal Code.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.305 - Section R105.1.1 of Chapter 1 Division II of the 2025 California…¶
[A]R105.1.1 Zoning Permits
A zoning permit may be required for items exempted from building permit requirements under Chapter 1 Division II Section 105.2. Exempted work shall not violate any provisions of this Code, Federal, State, Local laws, or regulations.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.310 - Section R301.1.3.2 of the 2025 Edition of the California Residential Code…¶
R301.1.3.2 Woodframe structures. The building official shall require construction documents to be approved and stamped by a California licensed architect or engineer for all dwellings of woodframe construction more than two stories and basement in height located in Seismic Design Category A, B or C. Notwithstanding other sections of law; the law establishing these provisions is found in Business and Professions Code Sections 5537 and 6737.1.
The building official shall require construction documents to be approved and stamped by a California licensed architect or engineer for all dwellings of woodframe construction more than one story in height or with a basement located in Seismic Design Category D 0 , D 1 , or D 2 .
(Ord. No. 7461, § 5, 11-10-2025)
14.04.315 - Section R301.1.5 is added to the 2025 California Residential Code to read as follows.¶
R301.1.5 Seismic design provisions for buildings constructed on or into slopes steeper than one unit vertical in three units horizontal (33.3 percent slope). The design and construction of new buildings and additions to existing buildings when constructed on or into slopes steeper than one unit vertical in three units horizontal (33.3 percent slope) shall comply with Section 1613.6 of the California Building Code.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.320 - Items 1, 3, and 5 of Section R301.2.2.6 of the 2025 Edition of the…¶
Shear wall or braced wall offsets out of plane. Conditions where exterior shear wall lines or braced wall panels are not in one plane vertically from the foundation to the uppermost story in which they are required.
Shear wall or braced wall offsets in plane. Conditions where the end of a braced wall panel occurs over an opening in the wall below.
Floor level offset. Conditions where portions of a floor level are vertically offset.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.325 - Section R301.2.2.11 is added to the 2025 Edition of the California…¶
R301.2.2.11 Anchorage of mechanical, electrical, or plumbing components and equipment. Mechanical, electrical, or plumbing components and equipment shall be anchored to the structure. Anchorage of the components and equipment shall be designed to resist loads in accordance with the California Building Code and ASCE 7, except where the component is positively attached to the structure and flexible connections are provided between the component and associated ductwork, piping, and conduit; and either
The component weighs 400 lb (1,780 N) or less and has a center of mass located 4 ft (1.25 m) or less above the supporting structure; or
The component weighs 20 lb (89N) or less or, in the case of a distributed system, 5 lb/ft (73 N/m) or less.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.330 - Section R309.1 of the 2025 Edition of the California Residential Code is…¶
R309.1 Townhouse automatic sprinkler systems.
An automatic sprinkler system shall be installed in townhouses. All new construction of buildings and structures shall be provided with an approved automatic fire sprinkler system.
Exception: An automatic sprinkler system shall not be required where additions or alterations are made to existing townhouses that do not have an automatic sprinkler system installed.
R309.1.1 Design and installation.
Automatic sprinkler systems for townhouses shall be designed and installed in accordance with Section R309 or NFPA 13D.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.335 - Section R309.2 of the 2025 Edition of the California Residential Code is…¶
R309.2 One- and two-family dwellings automatic sprinkler systems.
An automatic sprinkler system shall be installed in one- and two-family dwellings. All new construction of buildings and structures shall be provided with an approved automatic fire sprinkler system.
Exceptions:
- An automatic sprinkler system shall not be required for alterations to existing buildings that are not already provided with a sprinkler system.
Whenever additions result in an additional level above or below grade, or a total increase of more than 1000 square feet (92.9 m 2) or more, or an increase of more than fifty percent (50%) of the existing floor area including mezzanines and additional stories, whichever is less, regardless of ownership. Additions shall be cumulative with each application for a building permit from January 1, 2008 to present day. R-3 occupancies shall not be required to comply with this section solely due to the addition of an additional level, unless the criteria for an increase of existing floor area is also exceeded or if the addition exceeds a combined total floor area of 3,600 square feet and fire flow requirements are not met.
- Accessory Dwelling Unit, provided that all of the following are met:
2.1.
The unit meets the definition of an Accessory Dwelling Unit as defined in the Government Code Section 65852.2.
2.2.
The existing primary residence does not have automatic fire sprinklers.
2.3.
The accessory detached dwelling unit does not exceed 1,200 square feet in size.
2.4.
The unit is on the same lot as the primary residence.
2.5.
All portions of exterior walls are within 150 feet from fire access road as measured by an approved route approved by the Fire Official.
2.6.
All portions of exterior walls within 400 feet of a fire hydrant as measured by an approved route approved by the Fire Official.
Detached private garages, utility sheds, and similar structures 500 square feet or less, accessory to a R-3 occupancy, provided no portion of the structure is located more than 150 feet (45,720 mm) from an approved fire department access road.
Detached Carports, detached gazebos, pergolas, and similar shade structures open on all sides constructed of non-combustible material 500 square feet or less, accessory to a R-3 occupancy.
Other similar structures as deemed appropriate by the fire code official.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.340 - Section R309.3.1 of the 2025 Edition of the California Residential Code is…¶
R309.3.1 General.
The design and installation of automatic sprinkler systems shall be in accordance with NFPA 13D or Section R309.3, which shall be considered to be equivalent to NFPA 13D. Partial automatic sprinkler systems shall not be permitted to be installed only in buildings not required to be equipped with an automatic sprinkler system. Section R309.3 shall apply to standalone and multipurpose wet-pipe sprinkler systems that do not include the use of antifreeze. A multipurpose automatic sprinkler system shall provide domestic water to both fire sprinklers and plumbing fixtures. A stand-alone automatic sprinkler system shall be separate and independent from the water distribution system.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.345 - Section R309.3.5 of the 2025 Edition of the California Residential Code is…¶
R309.3.5 Water supply.
The water supply shall provide not less than the required design flow rate for sprinklers in accordance with Section R309.3.4.2 at a pressure not less than that used to comply with Section R309.3.6. Where a water supply serves both domestic and fire sprinkler systems, 5 gpm (19 L/min) shall be added to the sprinkler system demand at the point where the systems are connected, to determine the size of common piping and the size of the total water supply requirements where no provision is made to prevent flow into the domestic water system upon operation of a sprinkler. For multipurpose piping systems, the 5 gpm (19 L/min) demand shall be added at the domestic connection nearest the design area. This demand may be split between two domestic connections at 2.5 gpm (10 L/min) each. Hydraulic calculations shall include a 10% safety margin.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.350 - Section R401.1 of the 2025 Edition of the California Residential Code is…¶
R401.1 Application. The provisions of this chapter shall control the design and construction of the foundation and foundation spaces for buildings. In addition to the provisions of this chapter, the design and construction of foundations in flood hazard areas as established by Table R301.2 shall meet the provisions of Section R306. Wood foundations shall be designed and installed in accordance with AWC PWF.
Exception: The provisions of this chapter shall be permitted to be used for wood foundations only in the following situations:
In buildings that have no more than two floors and a roof.
When interior basement and foundation walls are constructed at intervals not exceeding 50 feet (15 240 mm).
Wood foundations in Seismic Design Category D 0 , D 1 , or D 2 shall not be permitted.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.355 - Sections R403.1.3.6, R403.1.5 of the 2025 Edition of the California…¶
R403.1.3.6 Isolated concrete footings. In detached one- and two-family dwellings located in Seismic Design Category A, B, or C, that are three stories or less in height, and constructed with stud bearing walls, isolated plain concrete footings supporting columns or pedestals are permitted.
R403.1.5 Slope. The top surface of footings shall be level. The bottom surface of footings shall not have a slope exceeding 1 unit vertical in 10 units horizontal (10-percent slope). Footings shall be stepped where it is necessary to change the elevation of the top surface of the footings or where the slope of the bottom surface of the footings will exceed one unit vertical in 10 units horizontal (10-percent slope).
For structures assigned to Seismic Design Categories D 0 , D 1 , or D 2 , stepped footings shall be reinforced with four No. 4 rebar. Two bars shall be place at the top and bottom of the footings as shown in Figure R403.1.5.
FIGURE R403.1.5 STEPPED FOOTING [Figure: FIGURE R403.1.5 STEPPED FOOTING]
(Ord. No. 7461, § 5, 11-10-2025)
14.04.360 - Section R404.2 of the 2025 Edition of the California Residential Code is…¶
R404.2 Wood foundation walls. Wood foundation walls shall be constructed in accordance with the provisions of Sections R404.2.1 through R404.2.6 and with the details shown in Figures R403.1(2) and R403.1(3). Wood foundation walls shall not be used for structures located in Seismic Design Category D 0 , D 1 , or D 2 .
(Ord. No. 7461, § 5, 11-10-2025)
14.04.365 - Section R501.2 of the 2025 Edition of the California Residential Code is…¶
R501.2 Requirements. Floor construction shall be capable of accommodating all loads in accordance with Section R301 and of transmitting the resulting loads to the supporting structural elements. Mechanical or plumbing fixtures and equipment shall be attached or anchored to the structure in accordance with Section R301.2.2.11.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.370 - Lines 20, 21, 24, and 34-37 of Table R602.3(1) of the 2025 Edition of the…¶
TABLE R602.3(1)—continued FASTENING SCHEDULE
| ITEM | DESCRIPTION OF BUILDING ELEMENTS | NUMBER AND TYPE OF FASTENER a, b, c | SPACING AND LOCATION | SPACING AND LOCATION |
|---|---|---|---|---|
| 20 k | 1" × 6" sheathing to each bearing | 3-8d box (2½" × 0.113"); or 2-8d common (2½" × 0.131"); or 2-10d box (3" × 0.128"); or 2 staples, 1" crown, 16 ga., 1¾" long | Face nail | Face nail |
| 21 k | 1" × 8" and wider sheathing to each bearing | 3-8d box (2½" × 0.113"); or 3-8d common (2½" × 0.131"); or 3-10d box (3" × 0.128"); or 3 staples, 1" crown, 16 ga., 1¾" long | Face nail | Face nail |
| 21 k | 1" × 8" and wider sheathing to each bearing | Wider than 1" × 8 " 4-8d box (2½" × 0.113"); or 3-8d common (2½" × 0.131"); or 3-10d box (3" × 0.128"); or 4 staples, 1" crown, 16 ga., 1¾" long | Face nail | Face nail |
| Floor | Floor | Floor | Floor | Floor |
| 24 k | 1" × 6" subfloor or less to each joist | 3-8d box (2½" × 0.113"); or 2-8d common (2½" × 0.131"); or 3-10d box (3" × 0.128"); or 2 staples, 1" crown, 16 ga., 1¾" long | Face nail | Face nail |
| Other wall sheathing g | Other wall sheathing g | Other wall sheathing g | Other wall sheathing g | Other wall sheathing g |
| 34 k | 1/2" structural cellulosic fiberboard sheathing | 1½" x 0.120"galvanized roofing nail, 7/16 " head diameter, or 1¼" long 16 ga. staple with 7/16 " or 1" crown | 3 | 6 |
| 35 k | 25/32" structural cellulosic fiberboard sheathing | 1¾" x 0.120" galvanized roofing nail, 7/16 " head diameter, or 1 ¼"long 16 ga. Staple with 7/16 " or 1" crown | 3 | 6 |
| 36 k | 1/2" gypsum sheathing d | 1½" x 0.120" galvanized roofing nail, 7/16 " head diameter, or 1¼" long, 16 ga.; staple galvanized, 1½" long; 7/16 " or 1" crown or 1¼" screws, Type W or S | 7 | 7 |
| 37 k | ⅝" gypsum sheathing d | 1¾" galvanized roofing nail, 7/16 " head diameter, or 1¼" long, 16 ga.; staple galvanized, 1½" long; 7/16 " or 1" crown or 1¼" screws, Type W or S | 7 | 7 |
k. Use of staples in roof, floor, and braced wall panels shall be prohibited in Seismic Design Category D 0 , D 1 , or D 2 .
(Ord. No. 7461, § 5, 11-10-2025)
14.04.375 - Footnote "b" of Table R602.3(2) of the 2025 Edition of the California…¶
b. Staples shall have a minimum crown width of 7/16-inch on diameter except as noted.
Use of staples in roof, floor, subfloor, and braced wall panels shall be prohibited in Seismic Design Category D 0 , D 1 , or D 2 .
(Ord. No. 7461, § 5, 11-10-2025)
14.04.380 - Section R602.3.2, Exception and Table R602.3.2 of the 2025 Edition of the…¶
Exception: In other than Seismic Design Category D 0 , D 1 or D 2 , a single top plate used as an alternative to a double top plate shall comply with the following:
The single top plate shall be tied at corners, intersecting walls, and at in-line splices in straight wall lines in accordance with Table R602.3.2.
The rafters or joists shall be centered over the studs with a tolerance of not more than 1 inch (25 mm).
Omission of the top plate is permitted over headers where the headers are adequately tied to adjacent wall sections in accordance with Table R602.3.2.
[Figure]
(Ord. No. 7461, § 5, 11-10-2025)
14.04.385 - Section R602.10.2.3 of the 2025 Edition of the California Residential Code…¶
R602.10.2.3 Minimum number of braced wall panels. Braced wall lines with a length of 16 feet (4877 mm) or less shall have not less than two braced wall panels of any length or one braced wall panel equal to 48 inches (1219 mm) or more. Braced wall lines greater than 16 feet (4877 mm) shall have not less than two braced wall panels.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.390 - Table R602.10.3(3) of the 2025 Edition of the California Residential Code…¶
[Figure]
[Figure]
a. Linear interpolation shall be permitted.
b. Interpolation of bracing length between the Sds values associated with the seismic design categories shall be permitted when a site-specific Sds value is determined in accordance with Section 1613.2 of the California Building Code.
c. Where the braced wall line length is greater than 50 feet, braced wall lines shall be permitted to be divided into shorter segments having lengths of 50 feet or less, and the amount of bracing within each segment shall be in accordance with this table.
d. Method LIB shall have gypsum board fastened to not less than one side with nails or screws in accordance with Table R602.3(1) for exterior sheathing or Table R702.3.5 for interior gypsum board. Spacing of fasteners at panel edges shall not exceed 8 inches.
e. Methods PFG and CS-SFB do not apply in Seismic Design Categories D0, D1 and D2.
f. Methods PFH, PFG and ABW are only permitted on a single story or a first of two stories.
g. Where more than one bracing method is used, mixing methods shall be in accordance with Section R602.10.4.1.
h. One- and two-family dwellings in Seismic Design Category D 2 exceeding two stories shall be designed in accordance with accepted engineering practice.
i. Methods GB and PCP braced wall panel h/w ratio shall not exceed 1:1 in SDC D0, D1 and D2. Methods DWB, SFB, PBS, HPS, and CS-SFB are not permitted in D0, D1 and D2.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.395 - Table R602.10.4 of the 2025 Edition of the California Residential Code is…¶
[Figure]
[Figure]
a. Adhesive attachment of wall sheathing, including Method GB, shall not be permitted in Seismic Design Categories C, D 0 , D 1 and D 2 .
b. Applies to panels next to garage door opening where supporting gable end wall or roof load only. Shall only be used on one wall of the garage. In Seismic Design Categories D 0 , D 1 and D 2 , roof covering dead load shall not exceed 3 psf.
c. Garage openings adjacent to a Method CS-G panel shall be provided with a header in accordance with Table R602.7(1). A full-height clear opening shall not be permitted adjacent to a Method CS-G panel.
d. Method CS-SFB does not apply in Seismic Design Categories D 0 , D 1 and D 2 .
e. Method applies to detached one- and two-family dwellings in Seismic Design Categories D 0 through D 2 only.
f. Methods GB and PCP braced wall panel h/w ratio shall not exceed 1:1 in SDC D 0 , D 1 and D 2 . Methods LIB, DWB, SFB, PBS, HPS, and PFG are not permitted in SDC D 0 , D 1 and D 2 .
g. Use of stapes in braced wall panels shall be prohibited in SDC D 0 , D 1 and D 2 .
(Ord. No. 7461, § 5, 11-10-2025)
14.04.400 - Table R602.10.5 of the 2025 Edition of the California Residential Code is…¶
TABLE R602.10.5 MINIMUM LENGTH OF BRACED WALL PANELS
[Figure]
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 0.447 m/s.
NP = Not Permitted.
a. Linear interpolation shall be permitted.
b. Use the actual length where it is greater than or equal to the minimum length. The actual length of Methods CS-G, CS-WSP, CS-SFB, PFH, PFG and CS-PF is the length of the full-height sheathed section.
c. Maximum header height for PFH is 10 feet in accordance with Figure R602.10.6.2, but wall height shall be permitted to be increased to 12 feet with pony wall.
d. Maximum header height for PFG is 10 feet in accordance with Figure R602.10.6.3, but wall height shall be permitted to be increased to 12 feet with pony wall.
e. Maximum header height for CS-PF is 10 feet in accordance with Figure R602.10.6.4, but wall height shall be permitted to be increased to 12 feet with pony wall.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.405 - Figure R602.10.6.1 of the 2025 Edition of the California Residential Code…¶
[Figure]
(Ord. No. 7461, § 5, 11-10-2025)
14.04.410 - Figure R602.10.6.2 of the 2025 Edition of the California Residential Code…¶
[Figure]
(Ord. No. 7461, § 5, 11-10-2025)
14.04.415 - Figure R602.10.6.4 of the 2025 Edition of the California Residential Code…¶
[Figure]
(Ord. No. 7461, § 5, 11-10-2025)
14.04.420 - Section R606.12.2.2.3 of the 2025 Edition of the California Residential…¶
R606.12.2.2.3 Reinforcement requirements for masonry elements. Masonry elements listed in Section R606.12.2.2.2 shall be reinforced in either the horizontal or vertical direction as shown in Figure R606.11(2) and in accordance with the following:
Horizontal reinforcement. Horizontal joint reinforcement shall consist of not less than one No. 4 bar spaced not more than 48 inches (1219 mm). Horizontal reinforcement shall be provided within 16 inches (406 mm) of the top and bottom of these masonry elements.
Vertical reinforcement. Vertical reinforcement shall consist of not less than one No. 4 bar spaced not more than 48 inches (1219 mm). Vertical reinforcement shall be within 8 inches (406 mm) of the ends of masonry walls.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.425 - Section R803.2.4 is added to Chapter 8 of the 2025 Edition of the…¶
R803.2.4 Openings in horizontal diaphragms. Openings in horizontal diaphragms shall conform with Section R503.2.4.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.430 - Section R902.1.1.1 is added to the 2025 Edition of the California…¶
All roofing material in the very-high and moderate fire hazard severity zone must be Class A. No wood roof covering material shall be installed on any structure located in the very high, high and moderate fire hazard severity zones as identified by the Pasadena Fire Department. All other roof covering materials in other zones shall be Class A or B.
Exception: In the moderate fire hazard severity zone, the fire code official may, upon a showing of good cause and necessity, approve the use of fire-resistive wood as part of Class A listed assemblies, and may require additional mitigation as warranted, for the repair or maintenance of existing structure.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.435 - Section R1001.3.1 of the 2025 Edition of the California Residential Code is…¶
R1001.3.1 Vertical reinforcing. For chimneys up to 40 inches (1016 mm) wide, four No. 4 continuous vertical bars adequately anchored into the concrete foundation shall be placed between wythes of solid masonry or within the cells of hollow unit masonry and grouted in accordance with Section R606. Grout shall be prevented from bonding with the flue liner so that the flue liner is free to move with thermal expansion. For chimneys more than 40 inches (1016 mm) wide, two additional No. 4 vertical bars adequately anchored into the concrete foundation shall be provided for each additional flue incorporated into the chimney or for each additional 40 inches (1016 mm) in width or fraction thereof.
(Ord. No. 7461, § 5, 11-10-2025)
14.04.440 - Section AX100.1 is added to the 2025 Edition of the California Residential…¶
In addition to the requirements of Appendix AX, the Swimming Pool Safety Act, of the 2025 California Residential Code, a swimming pool, pool, spa or any body of water over 18 inches deep shall have an enclosure consisting of a fence, wall, portions of a building or other approved durable material, that isolates all bodies of water from the public right of way, private single family dwelling, and Accessory Dwelling Unit. The enclosure shall be installed around the perimeter of the bodies of water, or at the perimeter of the property.
(Ord. No. 7461, § 5, 11-10-2025)