Division II — ADMINISTRATION. PART I. – GENERAL PROVISIONS.
Chapter 10 — MEANS OF EGRESS.
San Francisco Fire Code · 2022 edition · updated 2026-07-25 · San Francisco
SECTION 1010. – DOORS, GATES AND TURNSTILES. ¶
The following part of the San Francisco Fire Code section replaces the corresponding part of the California Fire Code section:
1010.1.2. [For SF] Door Swing.
- * * *
Exceptions:
In other than Group A, E, H, I, R, and high-rise building occupancies, special purpose horizontal sliding, accordion, or folding door assemblies complying with Section 1010.3.3.
- * * *
The following part of the San Francisco Fire Code section replaces the corresponding part of the California Fire Code section:
1010.1.4.3. [For SF] Special Purpose Horizontal Sliding Door, Accordion, or Folding Doors.
In other than Group A, E, H, I, R, and high-rise building occupancies, special purpose horizontal sliding, accordion, or folding door assemblies permitted to be a component of a means of egress in accordance with Exception 6 of Section 1010.1.2 shall comply with all of the following criteria:
- * * *
SECTION 1013. – EXIT SIGNS. ¶
The following part of the San Francisco Fire Code section adds to the corresponding California Fire Code section:
1013.1. [For SF] Where required.
- * * *
Exceptions:
- * * *
- Doorways or other openings leading to a fire escape, except within individual dwelling units, shall be provided with a sign reading “FIRE
E
SCAPE” in letters not less than 6 inches (152 mm) high, in high contrast with the background.
SECTION 1031. – EMERGENCY ESCAPE AND RESCUE. ¶
1031.2.2. Direct Access to Public Way.
When buildings are constructed on lot lines, an emergency escape and rescue egress may pass through the building via an exit passageway (per
SFFC Section 1024) with approval from the AHJ. The exit passageway shall be an independent exit access path to the public way from the building
u ni ts.
SECTION 1032. – MAINTENANCE OF THE MEANS OF EGRESS. ¶
1032.2.1.4. [For SF] Fire Escape Obstructions.
Fire escapes and related balconies, ladders, landings, and operating devices shall not be obstructed in any manner. No object shall be stored on or attached to a fire escape without the approval of the fire code official. Fire escapes shall not be located beyond a locked door or room that restricts immediate access to the fire escape from the corridor.
Exception: These restrictions shall not apply to a building in which every dwelling or commercial space within the building has immediate access to a fire escape without exiting the dwelling or space and entering the corridor.
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸ Contents — San Francisco Fire Code
- Chapter 1 — SAN FRANCISCO GENERAL CODE PROVISIONS.
-
▸ Division II — ADMINISTRATION. PART I. – GENERAL PROVISIONS.
Overview- Chapter 2 — DEFINITIONS.
- Chapter 3 — GENERAL PRECAUTIONS AGAINST FIRE.
- Chapter 4 — EMERGENCY PLANNING AND PREPAREDNESS.
- Chapter 5 — FIRE SERVICE FEATURES.
- Chapter 6 — BUILDING SERVICES AND SYSTEMS.
- Chapter 9 — FIRE-PROTECTION SYSTEMS.
- Chapter 10 — MEANS OF EGRESS.
- Chapter 11 — CONSTRUCTION REQUIREMENTS FOR EXISTING BUILDINGS.
- Chapter 33 — FIRE SAFETY DURING CONSTRUCTION AND DEMOLITION.
- Chapter 35 — HOT WORK.
- Chapter 56 — EXPLOSIVES AND FIREWORKS.
- Chapter 80 — REFERENCED STANDARDS.
- Chapter 81 — PARKING LOTS AND GARAGES.