Skip to content

Brawley · Zoning · A-1

Brawley A-1 zoning: height, setbacks and lot size

In Brawley's A-1 zone, generally buildings can be up to 35 ft (2 stories) tall, the front setback is 25–35 ft and the minimum lot size is 40 acres, with the conditions listed below (Brawley code, read October 2026).

Key points

  • Maximum building height: 35 ft (Primary structure)
  • Maximum number of stories: 2 stories (Primary structure)
  • Minimum front setback: 25–35 ft
  • Minimum side setback: 10 ft
  • Minimum rear setback: 25 ft
  • Minimum lot size: 40 acres
  • Maximum lot coverage: 2.5% (For 40 acres and greater)
  • Maximum floor area ratio (FAR): 0.25 (For 40 acres and greater)

A-1 (Light Agricultural) is a zoning district in Brawley. Every value below was read from the Brawley Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in A-1

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
Applies: Primary structure
§ 27.132 · code text
Table row “Primary Structure”, column “A-1”: 2 S/35 ft (13)
Maximum number of stories
2 stories
Applies: Primary structure
§ 27.132 · code text
Table row “Primary Structure”, column “A-1”: 2 S/35 ft (13)
Minimum front setback
25–35 ft
See notes 7, 10 below the table in the code.
§ 27.132 · code text
Table row “From Ultimate Street R-O-W”, column “A-1”: 25—35 ft
Note 7: Refer to section 27.169, Specialized front yard requirements.
Note 10: Front yard setback requirements are based on lot area as identified below:
Minimum side setback
10 ft
See note 8 below the table in the code.
§ 27.132 · code text
Table row “Interior Side”, column “A-1”: 10 ft
Note 8: Refer to section 27.170, Specialized side yard requirements.
Minimum rear setback
25 ft
See note 9 below the table in the code.
§ 27.132 · code text
Table row “Standard Lot”, column “A-1”: 25 ft
Note 9: Refer to section 27.171, Specialized rear yard adjoining an alley.
Minimum lot size
40 acres
See notes 2, 5 below the table in the code.
§ 27.132 · code text
Table row “(a) Minimum Lot Size (2),(4),(5)”, column “A-1”: 40 acres
Note 2: Development standard applies to proposed subdivisions of land.
Note 5: Refer to sections 27.161 through 27.164.
Maximum lot coverage
2.5%
Applies: For 40 acres and greater
§ 27.132 · code text
Table row “(g) Maximum Building Coverage (11)”, column “A-1”: 2.5% for 40 acres and greater
Maximum floor area ratio (FAR)
0.25
Applies: For 40 acres and greater
§ 27.132 · code text
Table row “(h) Maximum Floor Area Ratio (12)”, column “A-1”: 0.25 for 40 acres and greater

Uses in A-1

Uses the code's use tables allow in A-1, or allow with a permit. Each links to its page with the code section.

When a different number applies

The code sets other values for particular lots, buildings or locations in A-1:

  • Maximum building height: 150 ft — Specialized buildings that are an integral part of agricultural processing, unless restricted by airport land use plan § 27.132
  • Maximum lot coverage: 5% — For lots from ten to forty acres in size § 27.132
  • Maximum lot coverage: 10% — For lots less than ten acres in size § 27.132
  • Maximum floor area ratio (FAR): 0.05 — For lots from ten to forty acres in size § 27.132
  • Maximum floor area ratio (FAR): 0.1 — For lots less than ten acres in size § 27.132

Not on this page

We did not find a general density limit for A-1 in the zoning tables we read. The code may still set one elsewhere — check the Brawley Municipal Code.

Other Brawley zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Brawley's A-1 zone?

35 ft (primary structure) — Brawley Municipal Code § 27.132.

What is the maximum number of stories in Brawley's A-1 zone?

2 stories (primary structure) — Brawley Municipal Code § 27.132.

What is the minimum front setback in Brawley's A-1 zone?

25–35 ft — Brawley Municipal Code § 27.132.

What is the minimum side setback in Brawley's A-1 zone?

10 ft — Brawley Municipal Code § 27.132.

What is the minimum rear setback in Brawley's A-1 zone?

25 ft — Brawley Municipal Code § 27.132.

General information, not legal advice.

Ask about a Brawley property in A-1

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Brawley