Brawley · Zoning · R-A

Brawley R-A zoning: height, setbacks and lot size

In Brawley's R-A zone, buildings can be up to 35 ft (2 stories) tall, the front setback is 25 ft-35 ft and the minimum lot size is 1.0 acre (Brawley code, read October 2026).

Key points

  • Maximum building height: 35 ft
  • Maximum number of stories: 2 stories
  • Minimum front setback: 25 ft-35 ft
  • Minimum side setback: 7 ft—10 ft
  • Minimum rear setback: 25 ft
  • Minimum lot size: 1.0 acre
  • Maximum lot coverage: 55%
  • Maximum density: 1 unit per acre

R-A is a zoning district in Brawley. Every value below was read from the Brawley Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in R-A

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
See note 5 below the table in the code.
§ 27.73 · code text
Table row “Primary Structure”, column “R-A”: 2 S/35 ft (5)
Note 5: Whichever is less.
Maximum number of stories
2 stories
See note 5 below the table in the code.
§ 27.73 · code text
Table row “Primary Structure”, column “R-A”: 2 S/35 ft (5)
Note 5: Whichever is less.
Minimum front setback
25 ft-35 ft
See note 8 below the table in the code.
§ 27.73 · code text
Table row “From Ultimate Street R-O-W”, column “R-A”: 25 ft-35 ft (8)
Note 8: Lot width and front yard setback requirements are based on required lot area as identified below:
Minimum side setback
7 ft—10 ft
§ 27.73 · code text
Table row “Interior Side”, column “R-A”: 7 ft—10 ft
Minimum rear setback
25 ft
§ 27.73 · code text
Table row “Standard Lot”, column “R-A”: 25 ft
Minimum lot size
1.0 acre
See note 2 below the table in the code.
§ 27.73 · code text
Table row “(a) Minimum Lot Size (2),(4),(9)”, column “R-A”: 1.0 acre
Note 2: Development standard applies to proposed subdivisions of land.
Maximum lot coverage
55%
§ 27.73 · code text
Table row “(g) Maximum Building Coverage”, column “R-A”: 55%
Maximum density
1 unit per acre
§ 27.73 · code text
Table row “(h) Maximum Density”, column “R-A”: 1 DU/acre

Uses in R-A

Uses the code's use tables allow in R-A, or allow with a permit. Each links to its page with the code section.

Not on this page

We did not find a general FAR limit for R-A in the zoning tables we read. The code may still set one elsewhere — check the Brawley Municipal Code.

Other Brawley zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Brawley's R-A zone?

35 ft — Brawley Municipal Code § 27.73.

What is the maximum number of stories in Brawley's R-A zone?

2 stories — Brawley Municipal Code § 27.73.

What is the minimum front setback in Brawley's R-A zone?

25 ft-35 ft — Brawley Municipal Code § 27.73.

What is the minimum side setback in Brawley's R-A zone?

7 ft—10 ft — Brawley Municipal Code § 27.73.

What is the minimum rear setback in Brawley's R-A zone?

25 ft — Brawley Municipal Code § 27.73.

General information, not legal advice.

Ask about a Brawley property in R-A

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question