Campbell LI zoning: height, setbacks and lot size

In Campbell's LI zone, buildings can be up to 45 ft tall and the front setback is 10 ft (Campbell code, read October 2026).

Key points

  • Maximum building height: 45 ft
  • Minimum front setback: 10 ft
  • Minimum side setback: 5 ft or one-half the height of the adjacent building wall, whichever is greater (Where the side property line abuts residentially zoned property; otherwise 5 ft)
  • Minimum rear setback: 10 ft
  • Maximum floor area ratio (FAR): 1.0

LI is a zoning district in Campbell. Every value below was read from the Campbell Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in LI

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
45 ft
§ 21.10.050 · code text
Table row “Maximum height limit”, column “LI”: 45 ft.
Minimum front setback
10 ft
§ 21.10.050 · code text
Table row “Front”, column “LI”: 10 ft.
Minimum side setback
5 ft or one-half the height of the adjacent building wall, whichever is greater
Applies: Where the side property line abuts residentially zoned property; otherwise 5 ft
The code attaches notes 4, 5 to this value. This page does not show them; read the code before relying on the number.
§ 21.10.050 · code text
Table row “Side (each)”, column “LI”: A minimum of five feet or one-half the height of the building wall adjacent to the side property line (whichever is greater) when the side property line abuts a residentially zoned property or 5 feet when the side property line does not abut a residentially zoned property. (4) (5)
Minimum rear setback
10 ft
See notes 2, 6 below the table in the code.
§ 21.10.050 · code text
Table row “Rear”, column “LI”: 10 ft. (2) (6)
Note 2: The Planning Commission may grant a reduction or allow a structure to be placed on the rear property line and may designate that additional landscaping and setback requirements be provided at the front of the parcel.
Note 6: No rear setback shall be required for a proposed building when designed for, and limited for use as, an emergency shelter in accordance with CMC 21.36.085 (Emergency shelters).
Maximum floor area ratio (FAR)
1.0
See note 1 below the table in the code.
§ 21.10.050 · code text
Table row “Maximum floor area ratio”, column “LI”: 1.0 (1)
Note 1: Properties located within the Pruneyard/Creekside District 3.0 acres and larger shall be allowed to develop at a maximum F.A.R. of 2.0 as provided for by LU-8.7 of the General Plan. Properties located within the Winchester Boulevard Master Plan (WBMP) shall have a maximum F.A.R. of 1.5 as provided for on page 24 of the WBMP.

When a different number applies

The code sets other values for particular lots, buildings or locations in LI:

  • Minimum side setback: 5 ft — Does not abut residentially zoned property. Commission may allow less than 5 ft for a one-story industrial building, wall up to 30 ft § 21.10.050
  • Minimum side setback: 0 ft — Proposed building designed for and limited for use as an emergency shelter; side property line abuts a non-residentially zoned property; adjacent wall, including parapet, no taller than 30 feet and limited to one story § 21.10.050
  • Minimum rear setback: None required — Proposed building designed for and limited for use as an emergency shelter § 21.10.050
  • Maximum floor area ratio (FAR): 2.0 — Properties located within the Pruneyard/Creekside District 3.0 acres and larger § 21.10.050
  • Maximum floor area ratio (FAR): 1.5 — Properties located within the Winchester Boulevard Master Plan (WBMP) § 21.10.050

Not on this page

We did not find a general stories, lot size, lot coverage, density limit for LI in the zoning tables we read. The code may still set one elsewhere — check the Campbell Municipal Code.

Other Campbell zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Campbell's LI zone?

45 ft — Campbell Municipal Code § 21.10.050.

What is the minimum front setback in Campbell's LI zone?

10 ft — Campbell Municipal Code § 21.10.050.

What is the minimum side setback in Campbell's LI zone?

5 ft or one-half the height of the adjacent building wall, whichever is greater (where the side property line abuts residentially zoned property; otherwise 5 ft) — Campbell Municipal Code § 21.10.050. The code attaches notes or conditions to this value; read the section before relying on it.

What is the minimum rear setback in Campbell's LI zone?

10 ft — Campbell Municipal Code § 21.10.050.

What is the maximum floor area ratio (far) in Campbell's LI zone?

1.0 — Campbell Municipal Code § 21.10.050.

General information, not legal advice.

Ask about a Campbell property in LI

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question