Skip to content

Concord · Zoning · NC

Concord NC zoning: height, setbacks and lot size

In Concord's NC zone, generally buildings can be up to 40 ft tall, the front setback is 5 ft and the minimum lot size is 10,000 sq ft, with the conditions listed below (Concord code, read October 2026).

Key points

  • Maximum building height: 40 ft (Nonresidential)
  • Minimum front setback: 5 ft
  • Minimum side setback: None required (None required unless adjacent to an R district (or to a residential use in CMX))
  • Minimum rear setback: None required (None required unless adjacent to an R district (or to a residential use in CMX))
  • Minimum lot size: 10,000 sq ft
  • Maximum floor area ratio (FAR): 0.35

NC is a zoning district in Concord. Every value below was read from the Concord Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in NC

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
40 ft
Applies: Nonresidential
See notes 4, 6 below the table in the code.
§ 18.40.030 · code text
Table row “Nonresidential”, column “NC (4)(6)”: 40
Note 4: Standard does not apply to small, independent parcels corresponding to individual dwellings within a larger multifamily residential, mixed-use, or townhome development.
Note 6: Additional requirements may apply pursuant to Chapter 18.120 CDC (Affirmatively Furthering Fair Housing Overlay District).
Minimum front setback
5 ft
See notes 4, 6 below the table in the code.
§ 18.40.030 · code text
Table row “Front”, column “NC (4)(6)”: 5
Note 4: Standard does not apply to small, independent parcels corresponding to individual dwellings within a larger multifamily residential, mixed-use, or townhome development.
Note 6: Additional requirements may apply pursuant to Chapter 18.120 CDC (Affirmatively Furthering Fair Housing Overlay District).
Minimum side setback
None required
Applies: None required unless adjacent to an R district (or to a residential use in CMX)
See notes 4, 6 below the table in the code.
§ 18.40.030 · code text
Table row “Interior Side, Rear”, column “NC (4)(6)”: None required unless adjacent to an R district or residential use in CMX. See CDC 18.150.180 (Transitional requirements) for buildings up to 30 feet in height .
Note 4: Standard does not apply to small, independent parcels corresponding to individual dwellings within a larger multifamily residential, mixed-use, or townhome development.
Note 6: Additional requirements may apply pursuant to Chapter 18.120 CDC (Affirmatively Furthering Fair Housing Overlay District).
Minimum rear setback
None required
Applies: None required unless adjacent to an R district (or to a residential use in CMX)
See notes 4, 6 below the table in the code.
§ 18.40.030 · code text
Table row “Interior Side, Rear”, column “NC (4)(6)”: None required unless adjacent to an R district or residential use in CMX. See CDC 18.150.180 (Transitional requirements) for buildings up to 30 feet in height .
Note 4: Standard does not apply to small, independent parcels corresponding to individual dwellings within a larger multifamily residential, mixed-use, or townhome development.
Note 6: Additional requirements may apply pursuant to Chapter 18.120 CDC (Affirmatively Furthering Fair Housing Overlay District).
Minimum lot size
10,000 sq ft
See notes 4, 6 below the table in the code.
§ 18.40.030 · code text
Table row “Lot Area (square feet) minimum”, column “NC (4)(6)”: 10,000
Note 4: Standard does not apply to small, independent parcels corresponding to individual dwellings within a larger multifamily residential, mixed-use, or townhome development.
Note 6: Additional requirements may apply pursuant to Chapter 18.120 CDC (Affirmatively Furthering Fair Housing Overlay District).
Maximum floor area ratio (FAR)
0.35
See notes 4, 6 below the table in the code.
§ 18.40.030 · code text
Table row “Floor Area Ratio (FAR) (maximum)”, column “NC (4)(6)”: 0.35
Note 4: Standard does not apply to small, independent parcels corresponding to individual dwellings within a larger multifamily residential, mixed-use, or townhome development.
Note 6: Additional requirements may apply pursuant to Chapter 18.120 CDC (Affirmatively Furthering Fair Housing Overlay District).

Uses in NC

Uses the code's use tables allow in NC, or allow with a permit. Each links to its page with the code section.

Not on this page

We did not find a general stories, lot coverage, density limit for NC in the zoning tables we read. The code may still set one elsewhere — check the Concord Municipal Code.

Other Concord zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Concord's NC zone?

40 ft (nonresidential) — Concord Municipal Code § 18.40.030.

What is the minimum front setback in Concord's NC zone?

5 ft — Concord Municipal Code § 18.40.030.

What is the minimum side setback in Concord's NC zone?

None required (none required unless adjacent to an R district (or to a residential use in CMX)) — Concord Municipal Code § 18.40.030.

What is the minimum rear setback in Concord's NC zone?

None required (none required unless adjacent to an R district (or to a residential use in CMX)) — Concord Municipal Code § 18.40.030.

What is the minimum lot size in Concord's NC zone?

10,000 sq ft — Concord Municipal Code § 18.40.030.

General information, not legal advice.

Ask about a Concord property in NC

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Concord