Skip to content

Downey · Zoning · C-P

Downey C-P zoning: height, setbacks and lot size

In Downey's C-P zone, buildings can be up to 75 ft (5 stories) tall, the front setback is 10 ft and the minimum lot size is 6,000 sq ft (Downey code, read October 2026).

Key points

  • Maximum building height: 75 ft
  • Maximum number of stories: 5 stories
  • Minimum front setback: 10 ft
  • Minimum side setback: 5 ft (interior side setback abutting a nonresidential zone)
  • Minimum rear setback: 15 ft (abutting nonresidential zone)
  • Minimum lot size: 6,000 sq ft
  • Maximum lot coverage: 50%
  • Maximum floor area ratio (FAR): 2.0

C-P is a zoning district in Downey. Every value below was read from the Downey Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in C-P

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
75 ft
§ 9314.06 · code text
Table row “Building height — maximum (feet or stories, whichever is less) b”, column “C-P”: 75 feet or 5 stories
Maximum number of stories
5 stories
§ 9314.06 · code text
Table row “Building height — maximum (feet or stories, whichever is less) b”, column “C-P”: 75 feet or 5 stories
Minimum front setback
10 ft
§ 9314.06 · code text
Table row “front c”, column “C-P”: 10
Minimum side setback
5 ft
Applies: interior side setback abutting a nonresidential zone
§ 9314.06 · code text
Table row “abutting a nonresidential zone”, column “C-P”: 5
Minimum rear setback
15 ft
Applies: abutting nonresidential zone
§ 9314.06 · code text
Table row “abutting nonresidential zone”, column “C-P”: 15
Minimum lot size
6,000 sq ft
§ 9314.06 · code text
Table row “Lot area — minimum (square feet)”, column “C-P”: 6,000
Maximum lot coverage
50%
§ 9314.06 · code text
Table row “Lot coverage — maximum (percent)”, column “C-P”: 50
Maximum floor area ratio (FAR)
2.0
§ 9314.06 · code text
Table row “Floor area ratio — maximum”, column “C-P”: 2.0

Uses in C-P

Uses the code's use tables allow in C-P, or allow with a permit. Each links to its page with the code section.

When a different number applies

The code sets other values for particular lots, buildings or locations in C-P:

  • Minimum side setback: 46 ft — interior side setback abutting a residential zone § 9314.06
  • Minimum side setback: 10 ft — street abutting major roads § 9314.06
  • Minimum rear setback: 46 ft — abutting a residential zone § 9314.06

Not on this page

We did not find a general density limit for C-P in the zoning tables we read. The code may still set one elsewhere — check the Downey Municipal Code.

Other Downey zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Downey's C-P zone?

75 ft — Downey Municipal Code § 9314.06.

What is the maximum number of stories in Downey's C-P zone?

5 stories — Downey Municipal Code § 9314.06.

What is the minimum front setback in Downey's C-P zone?

10 ft — Downey Municipal Code § 9314.06.

What is the minimum side setback in Downey's C-P zone?

5 ft (interior side setback abutting a nonresidential zone) — Downey Municipal Code § 9314.06.

What is the minimum rear setback in Downey's C-P zone?

15 ft (abutting nonresidential zone) — Downey Municipal Code § 9314.06.

General information, not legal advice.

Ask about a Downey property in C-P

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Downey