Skip to content

Escalon · Zoning · C-1

Escalon C-1 zoning: height, setbacks and lot size

In Escalon's C-1 zone, buildings can be up to 35 ft tall, the front setback is 15 ft and the minimum lot size is 5,000 sq ft (Escalon code, read October 2026).

Key points

  • Maximum building height: 35 ft
  • Minimum front setback: 15 ft
  • Minimum side setback: None required
  • Minimum rear setback: None required
  • Minimum lot size: 5,000 sq ft
  • Maximum floor area ratio (FAR): 0.5

C-1 (Neighborhood Commercial District) is a zoning district in Escalon. Every value below was read from the Escalon Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in C-1

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
§ 17.18.040 · code text
Maximum height: 35 feet.
Minimum front setback
15 ft
§ 17.18.040 · code text
Front: 15 feet.
Minimum side setback
None required
§ 17.18.040 · code text
Side: None required.
Minimum rear setback
None required
§ 17.18.040 · code text
Rear: None required.
Minimum lot size
5,000 sq ft
§ 17.18.040 · code text
Minimum lot area: 5,000 square feet.
Maximum floor area ratio (FAR)
0.5
§ 17.18.040 · code text
Floor area ratio: 0.5.

Uses in C-1

Uses the code's use tables allow in C-1, or allow with a permit. Each links to its page with the code section.

When a different number applies

The code sets other values for particular lots, buildings or locations in C-1:

  • Minimum front setback: 20 ft — Along property lines of a C-1 lot that abut or are across the street or alley from a lot in a residential zone § 17.18.040
  • Minimum side setback: 10 ft — Side abutting a street, along property lines of a C-1 lot that abut or are across the street or alley from a lot in a residential zone § 17.18.040
  • Minimum side setback: 20 ft — Side along property lines of a C-1 lot that abut or are across the street or alley from a lot in a residential zone § 17.18.040
  • Minimum rear setback: 20 ft — Rear along property lines of a C-1 lot that abut or are across the street or alley from a lot in a residential zone § 17.18.040

Not on this page

We did not find a general stories, lot coverage, density limit for C-1 in the zoning tables we read. The code may still set one elsewhere — check the Escalon Municipal Code.

Other Escalon zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Escalon's C-1 zone?

35 ft — Escalon Municipal Code § 17.18.040.

What is the minimum front setback in Escalon's C-1 zone?

15 ft — Escalon Municipal Code § 17.18.040.

What is the minimum side setback in Escalon's C-1 zone?

None required — Escalon Municipal Code § 17.18.040.

What is the minimum rear setback in Escalon's C-1 zone?

None required — Escalon Municipal Code § 17.18.040.

What is the minimum lot size in Escalon's C-1 zone?

5,000 sq ft — Escalon Municipal Code § 17.18.040.

General information, not legal advice.

Ask about an Escalon property in C-1

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Escalon