Skip to content

Escalon · Zoning · R-3

Escalon R-3 zoning: height, setbacks and lot size

In Escalon's R-3 zone, generally buildings can be up to 35 ft (2 stories) tall, the front setback is 20 ft and the minimum lot size is 7,500 sq ft, with the conditions listed below (Escalon code, read October 2026).

Key points

  • Maximum building height: 35 ft
  • Maximum number of stories: 2 stories
  • Minimum front setback: 20 ft (When no front porch is provided.)
  • Minimum side setback: 5 ft
  • Minimum rear setback: 20 ft
  • Minimum lot size: 7,500 sq ft (For the first two dwelling units; each additional unit needs 1,500 sq ft more.)
  • Maximum lot coverage: 70%

R-3 (Multiple-Family Residential District) is a zoning district in Escalon. Every value below was read from the Escalon Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in R-3

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
§ 17.16.040 · code text
Maximum height: Two stories, but not exceeding 35 feet.
Maximum number of stories
2 stories
§ 17.16.040 · code text
Maximum height: Two stories, but not exceeding 35 feet.
Minimum front setback
20 ft
Applies: When no front porch is provided.
§ 17.16.040 · code text
Front: 15 feet when a front porch is provided; 20 feet when no porch is provided, and the minimum depth of a front porch shall be six feet and a minimum of 60 square feet.
Minimum side setback
5 ft
§ 17.16.040 · code text
Side: Five feet.
Minimum rear setback
20 ft
§ 17.16.040 · code text
Rear: 20 feet. On corner lots, the rear yard for any building shall be not less than 10 feet in depth.
Minimum lot size
7,500 sq ft
Applies: For the first two dwelling units; each additional unit needs 1,500 sq ft more.
§ 17.16.040 · code text
Minimum lot area: 7,500 square feet for the first two dwelling units, with 1,500 square feet for each additional dwelling unit.
Maximum lot coverage
70%
§ 17.16.040 · code text
Maximum building coverage: 70 percent.

Uses in R-3

Uses the code's use tables allow in R-3, or allow with a permit. Each links to its page with the code section.

When a different number applies

The code sets other values for particular lots, buildings or locations in R-3:

  • Minimum front setback: 15 ft — When a front porch is provided § 17.16.040
  • Minimum front setback: 25 ft — When the garage door is facing the street § 17.16.040
  • Minimum rear setback: 10 ft — On corner lots § 17.16.040

Not on this page

We did not find a general FAR, density limit for R-3 in the zoning tables we read. The code may still set one elsewhere — check the Escalon Municipal Code.

Other Escalon zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Escalon's R-3 zone?

35 ft — Escalon Municipal Code § 17.16.040.

What is the maximum number of stories in Escalon's R-3 zone?

2 stories — Escalon Municipal Code § 17.16.040.

What is the minimum front setback in Escalon's R-3 zone?

20 ft (when no front porch is provided) — Escalon Municipal Code § 17.16.040.

What is the minimum side setback in Escalon's R-3 zone?

5 ft — Escalon Municipal Code § 17.16.040.

What is the minimum rear setback in Escalon's R-3 zone?

20 ft — Escalon Municipal Code § 17.16.040.

General information, not legal advice.

Ask about an Escalon property in R-3

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Escalon