Skip to content

Fowler · Zoning · PF

Fowler PF zoning: height, setbacks and lot size

In Fowler's PF zone, buildings can be up to 35 ft tall, the front setback is 10 ft and the minimum lot size is 0 sq ft (Fowler code, read October 2026).

Key points

  • Maximum building height: 35 ft
  • Minimum front setback: 10 ft
  • Minimum side setback: 5 ft
  • Minimum rear setback: 10 ft
  • Minimum lot size: 0 sq ft
  • Maximum lot coverage: 40%

PF is a zoning district in Fowler. Every value below was read from the Fowler Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in PF

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
§ 9.135.040 · code text
Table row “Maximum Building Height”, column “PF”: 35
Minimum front setback
10 ft
§ 9.135.040 · code text
Table row “Front Yard”, column “PF”: 10
Minimum side setback
5 ft
§ 9.135.040 · code text
Table row “Interior Side Yard 2”, column “PF”: 5
Minimum rear setback
10 ft
§ 9.135.040 · code text
Table row “Rear Yard 2”, column “PF”: 10
Minimum lot size
0 sq ft
§ 9.135.040 · code text
Table row “Site Area (sqft)”, column “PF”: 0
Maximum lot coverage
40%
§ 9.135.040 · code text
Table row “Maximum Lot Coverage”, column “PF”: 40%

When a different number applies

The code sets other values for particular lots, buildings or locations in PF:

  • Minimum side setback: 10 ft — Where a commercial lot directly abuts a lot within a residential district § 9.135.040

Not on this page

We did not find a general stories, FAR, density limit for PF in the zoning tables we read. The code may still set one elsewhere — check the Fowler Municipal Code.

Other Fowler zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Fowler's PF zone?

35 ft — Fowler Municipal Code § 9.135.040.

What is the minimum front setback in Fowler's PF zone?

10 ft — Fowler Municipal Code § 9.135.040.

What is the minimum side setback in Fowler's PF zone?

5 ft — Fowler Municipal Code § 9.135.040.

What is the minimum rear setback in Fowler's PF zone?

10 ft — Fowler Municipal Code § 9.135.040.

What is the minimum lot size in Fowler's PF zone?

0 sq ft — Fowler Municipal Code § 9.135.040.

General information, not legal advice.

Ask about a Fowler property in PF

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Fowler