In Fowler's R-4 zone, generally buildings can be up to 35 ft (2 stories) tall and the front setback is 15 ft, with the conditions listed below (Fowler code, read October 2026).

Key points

  • Maximum building height: 35 ft
  • Maximum number of stories: 2 stories
  • Minimum front setback: 15 ft (May drop to the block average if over 50% of block frontage is under the minimum. Garages: 20 ft (street access) or 10 ft (alley).)
  • Minimum side setback: 3 ft on one side; 8 ft combined (Table lists 3 to 5 ft; note 7 sets the minimum)
  • Minimum rear setback: 10 ft
  • Maximum lot coverage: 55%

R-4 is a zoning district in Fowler. Every value below was read from the Fowler Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in R-4

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
§ 9.120.040 · code text
Table row “Maximum Building Height”, column “R-4”: 35 / 2 stories
Maximum number of stories
2 stories
§ 9.120.040 · code text
Table row “Maximum Building Height”, column “R-4”: 35 / 2 stories
Minimum front setback
15 ft
Applies: May drop to the block average if over 50% of block frontage is under the minimum. Garages: 20 ft (street access) or 10 ft (alley).
§ 9.120.040 · code text
Table row “Front Yard 4,5”, column “R-4”: 15
Minimum side setback
3 ft on one side; 8 ft combined
Applies: Table lists 3 to 5 ft; note 7 sets the minimum
§ 9.120.040 · code text
Table row “Interior Side Yard 6”, column “R-4”: 3 to 5 7
Minimum rear setback
10 ft
§ 9.120.040 · code text
Table row “Rear Yard”, column “R-4”: 10
Maximum lot coverage
55%
§ 9.120.040 · code text
Table row “Maximum Lot Coverage”, column “R-4”: 55%

When a different number applies

The code sets other values for particular lots, buildings or locations in R-4:

  • Minimum side setback: 10 ft — Side yards providing access to more than one unit. § 9.120.040

Not on this page

We did not find a general lot size, FAR, density limit for R-4 in the zoning tables we read. The code may still set one elsewhere — check the Fowler Municipal Code.

Other Fowler zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Fowler's R-4 zone?

35 ft — Fowler Municipal Code § 9.120.040.

What is the maximum number of stories in Fowler's R-4 zone?

2 stories — Fowler Municipal Code § 9.120.040.

What is the minimum front setback in Fowler's R-4 zone?

15 ft (may drop to the block average if over 50% of block frontage is under the minimum. Garages: 20 ft (street access) or 10 ft (alley)) — Fowler Municipal Code § 9.120.040.

What is the minimum side setback in Fowler's R-4 zone?

3 ft on one side; 8 ft combined (table lists 3 to 5 ft; note 7 sets the minimum) — Fowler Municipal Code § 9.120.040.

What is the minimum rear setback in Fowler's R-4 zone?

10 ft — Fowler Municipal Code § 9.120.040.